starter smoking when first coming on
14 of 21 people
found this instruction helpful.
-
Michael from Ayden, NC
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
The retaining wire keeping the starter in place was first removed then the starter was easily removed. Pulling the old wire off was a little difficult because I had to pull harder than I expected. Getting the wire back on was probably the hardest part. I had to compress one part of the plug so I could get it to fit back on then it was
... Read more
simply a matter of placing the starter back in position and replacing the wire that holds it snugly in place. 20 minutes or so start to finish and new starter works well.
Read less
Was this helpful?
Thank you for voting!
Fan Motor not working
13 of 21 people
found this instruction helpful.
-
Richard from Albuquerque, NM
- Really Easy
- 15 - 30 mins
-
Screw drivers
Fist I removed the tow screws that hole the fan bracket - then remove the 2 screws that hole the fan-disconnect the wires and replace new unit.
Was this helpful?
Thank you for voting!
Freezer and refrigerator stopped cooling
8 of 8 people
found this instruction helpful.
-
Amy from PITTSBURGH, PA
- Easy
- Less than 15 mins
-
Screw drivers
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.
Was this helpful?
Thank you for voting!
Freezer not defrosting
8 of 9 people
found this instruction helpful.
-
Tom from Argyle, WI
- Really Easy
- 15 - 30 mins
-
Nutdriver
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside
... Read more
freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
Read less
Was this helpful?
Thank you for voting!
defrost thermostat was open most of the time and didn't let the defrost element heat up.
9 of 13 people
found this instruction helpful.
-
Elvin from Gardner, KS
- Easy
- 15 - 30 mins
-
Nutdriver
Removed evaporator cover, unplug 2 wires to thermostat, unclipped it from the coil. Installed new themostat back the same way.
Was this helpful?
Thank you for voting!
Freezer making annoying high pitched sound (like a whine)
6 of 6 people
found this instruction helpful.
-
Greg from NAVARRE, FL
- Very Easy
- 30 - 60 mins
-
Screw drivers
Parts Select included a video, and I watched a couple more that were on YouTube. Watch the video and do the repair . . . it's very easy took me about 35 min once I got the freezer emptied, including cleaning the freezer. I used a Philips head screw driver and I think it was a 5/16 nut driver . . . you can do this. Freezer running fine,
... Read more
no noise. One thing I would be careful on is removing the back plate that covers the fan and motor, the edges can be sharp and you could cut yourself removing the back plate. Also don't try to put the rubber gasket in before you replace the back plate, install the back plate and the rubber gasket goes in easy peasy :)
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
The freezer was not keeping food frozen
6 of 7 people
found this instruction helpful.
-
Jeffry from VERONA, WI
- Easy
- 1- 2 hours
-
Screw drivers
I replaced the timer and the defrost thermostat. The defrost thermostat replacement was almost exactly like the training video here. The old part attached slightly differently. The most time consuming part was thawing out the heat exchanger, which was completely covered with ice, inside and out.
Compared to the training video, ... Read more the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Compared to the training video, ... Read more the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Freezer was freezing solid
6 of 7 people
found this instruction helpful.
-
Matt from Cincinnati, OH
- Easy
- Less than 15 mins
-
Pliers
I first replaced the defrost timer about a week prior and it did not correct the problem. I then ordered the thermostat from partselect and within 15 minutes had the part installed. My refridgerator has been running correctly for a couple weeks.
Was this helpful?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
5 of 5 people
found this instruction helpful.
-
Bruce from MARTINEZ, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to ... Read more uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to ... Read more uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Read less
Was this helpful?
Thank you for voting!
Freezer was running too warm
6 of 8 people
found this instruction helpful.
-
Jeanne from SAN ANTONIO, TX
- Very Easy
- Less than 15 mins
-
Screw drivers
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Was this helpful?
Thank you for voting!
Refigerator Not Staying Cold
5 of 5 people
found this instruction helpful.
-
Marsha from BEVERLY, MA
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers, Wrench set
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely
... Read more
does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
Read less
Was this helpful?
Thank you for voting!
Fridge would not cool at all, because the compressor was not running. Fan running, lights working, just no cool.
4 of 4 people
found this instruction helpful.
-
David from ABINGDON, VA
- Easy
- 15 - 30 mins
-
Screw drivers
Remove the cardboard access cover at the bottom back of the fridge. On the left side, locate the run capacitor. Remove it by prying it loose from its socket, after first removing the wire hold down clamp. One wonders why the clamp is there, which makes it difficult to get the run capacitor out. Be careful not to disrupt in any way the cop
... Read more
per refrigerant tubes. If you mess them up, you will have wasted your time and effort trying to repair the machine. I was lucky, since a failed run capacitor is the problem only about 12% of the time, based on what I’ve read. Hallelujah! It was the problem with my fridge.
Read less
Was this helpful?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
5 of 7 people
found this instruction helpful.
-
gary from ARANSAS PASS, TX
- Easy
- 30 - 60 mins
-
Nutdriver
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though ... Read more it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though ... Read more it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Read less
Was this helpful?
Thank you for voting!
Freezer fan stoped working.
6 of 11 people
found this instruction helpful.
-
RICHARD from LANCASTER, PA
- Really Easy
- 15 - 30 mins
-
Screw drivers
Took longer to take out the shelves and the 10 screws holding the cover on then to replace the fan.
Local parts supply told me it would take two weeks to get the fan mator,ordered it from parts select and had in a couple days.
Local parts supply told me it would take two weeks to get the fan mator,ordered it from parts select and had in a couple days.
Was this helpful?
Thank you for voting!
Pushbutton light switch failed.
4 of 5 people
found this instruction helpful.
-
Arlee from HOUSTON, TX
- Very Easy
- 15 - 30 mins
-
Screw drivers
Needed a Phillips head screwdriver to remove bottom plate (kick panel). UNPLUGGED FREEZER. Removed plate pulled switch out through the mounting hole and unhooked the two electric wires. Plac
... Read more
ed wires on new switch, pushed wires back through the hole and seated the switch. Plugged in the freezer and opened the door - magic, the light came on. Replaced the front kick panel (hardest part was to line up the plate holes with the holes in the mounting bracket).
Read less
Was this helpful?
Thank you for voting!