Mullion not working. Replaced mullion.
4 of 4 people
found this instruction helpful.
-
David from DIAMOND BAR, CA
- Very Easy
- Less than 15 mins
-
Screw drivers
1. Turned power off.
2. Removed 2 screws holding plastid plate which connected electrical wire from mullion to door (requires Torq-tip screwdriver).
3. Unplugged wire plug behind the plate.
4. Lifted up old mullion from 2 slots holding it in place to remove it from door.
5. Inserted new mullion into slots on door. ... Read more
6. Connected electrical wire to plug inside door.
7. Screwed 2 screws to reattached plastic plate to door.
8. Turned power back on.
2. Removed 2 screws holding plastid plate which connected electrical wire from mullion to door (requires Torq-tip screwdriver).
3. Unplugged wire plug behind the plate.
4. Lifted up old mullion from 2 slots holding it in place to remove it from door.
5. Inserted new mullion into slots on door. ... Read more
6. Connected electrical wire to plug inside door.
7. Screwed 2 screws to reattached plastic plate to door.
8. Turned power back on.
Read less
Was this helpful?
Thank you for voting!
While cleaning, I Broke the glass that tops the 2 vegetable drawers.
4 of 4 people
found this instruction helpful.
-
Joanne from YORBA LINDA, CA
- Very Easy
- Less than 15 mins
The glass fits easily under a plastic ridge that is the frame holding the 2 vegetable drawers below. Slide the back side of the glass under the ridge, and then gently place the front of the glass in the groove where it goes on top of the vegetable drawers.
Its Super simple, and takes literally 30 seconds to complete.
Its Super simple, and takes literally 30 seconds to complete.
Was this helpful?
Thank you for voting!
After power outage, my refrigerator would not cool after power came back.
4 of 4 people
found this instruction helpful.
-
Denise from Finleyville, PA
- Very Easy
- 15 - 30 mins
-
Socket set
After looking up what might be the problem, I ordered a new control
board. It was extremely easy to replace. Unfortunately it was not operational. I had to replace my refrigerator. The return process was very easy and my refund was processed quickly.
board. It was extremely easy to replace. Unfortunately it was not operational. I had to replace my refrigerator. The return process was very easy and my refund was processed quickly.
Was this helpful?
Thank you for voting!
noise evap fan motor
4 of 4 people
found this instruction helpful.
-
LARRY from GEORGETOWN, TX
- Really Easy
- 30 - 60 mins
-
Nutdriver
Remove all trays, no need to turn app. off,
remove cover on top of back panel, may be a little difficult
remove 2 screws , one behind top plate, one in the middle of large back cover.
remove small cover located at the bottom of the back cover discinnect electrical plug,
remove or loosen 6 screws on lower evap co ... Read more ver, there is no need to remove evap cover, just pry it loose from back.
lift back cover off and disconnect electrical fan will be at the bottom of the large cover.
run warm water over fan and push out.
remove rubber cover and install on new fan,
reinstall new fan and reverse process.
very easy and simple and only takes about 30 minutes.
remove cover on top of back panel, may be a little difficult
remove 2 screws , one behind top plate, one in the middle of large back cover.
remove small cover located at the bottom of the back cover discinnect electrical plug,
remove or loosen 6 screws on lower evap co ... Read more ver, there is no need to remove evap cover, just pry it loose from back.
lift back cover off and disconnect electrical fan will be at the bottom of the large cover.
run warm water over fan and push out.
remove rubber cover and install on new fan,
reinstall new fan and reverse process.
very easy and simple and only takes about 30 minutes.
Read less
Was this helpful?
Thank you for voting!
This model of refrigerator has a dual cooling system and it was the refer condenser fan that was making noise
4 of 4 people
found this instruction helpful.
-
Jerry from BELLINGHAM, WA
- Really Easy
- 30 - 60 mins
-
Nutdriver
You have to remove the shelves and drawer's along with the drawer mount. there is a wiring harness you need to unclip to remove the crisper electrical panel
There are six nuts to remove the lower panel at the back of the compartment where the lower drawer normally is. no need to completely remove the panel, you only need to get ... Read more wiggle room to remove the fan at the base of the center panel.
There is a small triangular cover used to conceal the fan wiring harness on the right side of the center panel that you can use the putty knife to slip in on the center panel side to unclip and remove
Use the putty knife and slide it down both sides of the center panel that runs vertically to unclip it - at the base of this panel is where you'll find the condenser fan, you should be able to wiggle it out - there is a built in clip on the lower right side of the center panel that you can slip the wiring harness out of - for me this was the hardest part of the replacement as it was just awkward.
After it's removed slip in the new fan and seal and reassemble. I think the whole operation took maybe a half hour - 40 minutes. It's pretty easy all said and done.
There are six nuts to remove the lower panel at the back of the compartment where the lower drawer normally is. no need to completely remove the panel, you only need to get ... Read more wiggle room to remove the fan at the base of the center panel.
There is a small triangular cover used to conceal the fan wiring harness on the right side of the center panel that you can use the putty knife to slip in on the center panel side to unclip and remove
Use the putty knife and slide it down both sides of the center panel that runs vertically to unclip it - at the base of this panel is where you'll find the condenser fan, you should be able to wiggle it out - there is a built in clip on the lower right side of the center panel that you can slip the wiring harness out of - for me this was the hardest part of the replacement as it was just awkward.
After it's removed slip in the new fan and seal and reassemble. I think the whole operation took maybe a half hour - 40 minutes. It's pretty easy all said and done.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
I lack physical strength
6 of 10 people
found this instruction helpful.
-
Sheryl from SAINT LOUIS, MO
- Really Easy
- 30 - 60 mins
I asked two strong male neighbors to do the work and told them how to do it. Follow the simple directions on the box. You can Google it, but it will tell you the same directions.
Was this helpful?
Thank you for voting!
fan noise
4 of 4 people
found this instruction helpful.
-
Robert from LA PLATA, MD
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
followed install on line
Was this helpful?
Thank you for voting!
Malfunctioning ice maker
5 of 8 people
found this instruction helpful.
-
Glen from STATEN ISLAND, NY
- Really Easy
- 30 - 60 mins
-
Socket set
Used ratchet set, and unscrewed old one and screwed in new. Disconnected the wires and plugged in new one.
Was this helpful?
Thank you for voting!
Refrigerator light wouldn't come on.
4 of 5 people
found this instruction helpful.
-
Daniel from Crown Point, IN
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
Was this helpful?
Thank you for voting!
Difficulty in removing the old switch
5 of 8 people
found this instruction helpful.
-
James from Federal Way, AL
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers, Socket set
The old switch was hard to remove. Thinking that I may have to loosen the wires I used a socket wrench to remove a clamp. This was unnecessary. In the end the switch did come out using a large size screwdriver. The problem was that the expanding plastic tongue is not visible from the ouside so you have to try to feel your way around.
... Read more
If i had ordered the replacement before and not afterwards I would have seen this before hand.
Read less
Was this helpful?
Thank you for voting!
Interior light would not come on when right hand door was open
4 of 5 people
found this instruction helpful.
-
brian from CLOQUET, MN
- Very Easy
- 15 - 30 mins
-
Screw drivers
Remove the screws from the two door pivot covers. Remove the covers and set aside. Remove the screws from the control board; disconnect the electrical connections; remove the door light switch, install door light switch then reinstall everything.
Was this helpful?
Thank you for voting!
slider that holds ballbearings was missing in upper drawer
3 of 3 people
found this instruction helpful.
-
Matt from STERLING HTS, MI
- Easy
- 30 - 60 mins
-
Screw drivers, Socket set
ordered new slider left side
Was this helpful?
Thank you for voting!
Dairy bin did not come with the refrigerator
3 of 3 people
found this instruction helpful.
-
James from KYLE, TX
- Really Easy
- Less than 15 mins
Slipped into place easily.
Was this helpful?
Thank you for voting!
Interior Light did not go on due to faulty switch
4 of 6 people
found this instruction helpful.
-
Robert from Coto de Caza, CA
- Really Easy
- Less than 15 mins
I ordered two switches, replaced both with a knife in 10 minutes. Interior light works, thanks.
Was this helpful?
Thank you for voting!
refriderator not cooling consistetly
4 of 6 people
found this instruction helpful.
-
randall from coopersville, MI
- Easy
- Less than 15 mins
-
Pliers, Screw drivers
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
Was this helpful?