PLFU1778ES1 Frigidaire Freezer - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Fan motor no longer functioning and needed to be replaced
12 of 12 people
found this instruction helpful.
-
Amber from SHERMANS DALE, PA
- Very Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Socket set
The most difficult part was the removal of the existing fan and shroud. There is very little room to work between the condenser and the coils where the fan is located. The old shroud had to be removed as it was not compatible with the mounting for the new fan motor and blade. Make sure to unplug the refrigerator and give the coils some
... Read more
time to cool down. The first step was to remove the old fan blade... it simply pulls off. Next you need to remove the two bolts holding the fan shroud to the floor of the refrigerator. Then you need to remove the old fan motor from the shroud... unplug the wire connection and remove two small bolts that hold it on. I was lucky to have a VERY small ratchet to get into these tight spaces. Now is the really hard part, removing the metal fan shroud takes a lot of twisting and turning to get it out. The coils have a little play in them, but you must be very careful of the tubing and connections. Also, the coils are very sharp. Once this is out, IF you can get it out....I had my doubts along the way, you can start to put the new parts in... beginning with the new fan shroud which fortunately is made of plastic and has some give which makes it easier to get in. Then you can mount the new motor to the shroud with the three new screws. Plug in the wire connection, add the foam tape to the shroud and mount the shroud to the floor of the frig with the original two bolts. Lastly, attach the fan blade. This replacement kit is well constructed, fits perfectly and contained all the necessary parts (fan motor with wiring connection, mounting screws, wire connection adapter, fan shroud, foam tape and fan blade), but no detailed instructions come with it. I was lucky to get the old fan shroud out without doing any damage to the surrounding parts, but this part was very difficult for a do it yourself person. I would be interested to know if a professional has some other tips for this part of the replacement process.
Read less
Was this helpful?
Thank you for voting!
Freezer would not run; no electrical power to the compressor
11 of 12 people
found this instruction helpful.
-
Gary from SEQUIM, WA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
Looking on-line at your diagnostic for this problem, I saw the most common part to cause this problem was the start capacitor, so I purchased one & installed it with no positive outcome. I then purchased the next recommended part which was a defrost timer & installed it with no run again. Frustrated, I looked at another diagnostic web s
... Read more
ite that claimed 90% of the time the problem is caused by the cold control thermostat. I tested mine and it tested bad, so I bought a control elsewhere, since your site did not list a PN for that device. I installed the new control and the freezer started up correctly. Looking at the wiring diagram for these parts, I see the start capacitor and defrost control are downstream of the cold control thermostat, and to my mind should have been the first part recommended for testing versus the parts I bought, so I am somewhat disappointed in the diagnostics on your site, where I spent about $80 for parts that were functional.
Read less
Was this helpful?
Thank you for voting!
frezer not staying cold enough to freze newly added product
13 of 18 people
found this instruction helpful.
-
Robert H. from Grand Blanc, MI
- Really Easy
- 15 - 30 mins
-
Screw drivers
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part.
... Read more
Thank you
Read less
Was this helpful?
Thank you for voting!
Freezer had stopped cooling for almost 30hours.
9 of 9 people
found this instruction helpful.
-
Rex from Ritzville, WA
- Really Easy
- 30 - 60 mins
-
Screw drivers
Turned thermostat down and freezer began to run. Once it was at desired temp it shut down and did not start again. Turning the thermostat down again caused the freezer to start again. At this point, decided the thermostat was defective.Unplugged the freezer and removed the shelving. Removed the knob from the thermostat. Removed the n
... Read more
ine screws that held the back panel in place and pulled the panel forward. Removed the assembly that held the sensing tube in place and removed the sensing tube from it. Depressed the thermostat latch which holds it in the back panel and separated it from the panel. Removed the electrical connections and removed the thermostat assembly from the freezer. Reinstalled the new thermostat in the reverse order.
Read less
Was this helpful?
Thank you for voting!
Evap fan motor intermitant
11 of 17 people
found this instruction helpful.
-
Mike from Los Banos, CA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Removed evap cover from Commercial Refrigerator. Removed mounting screws from Evap motor mount. Replaced evap fan motor. Repositioned. Reinstalled evap cover. Tested . This motor was hard to find locally. Glad I called.
Was this helpful?
Thank you for voting!
Freezer not defrosting
8 of 9 people
found this instruction helpful.
-
Tom from Argyle, WI
- Really Easy
- 15 - 30 mins
-
Nutdriver
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside
... Read more
freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
Read less
Was this helpful?
Thank you for voting!
broken fan with vacumme cleaner
9 of 12 people
found this instruction helpful.
-
TIM from Lockport, IL
- Really Easy
- Less than 15 mins
-
Nutdriver
I remembered to unplug first. took the little cover off on the bottom, unscrewed the 3 screws. then just held the base that the fan is on and pulled rite off, pushed the other one rite on. it took me five min, i want to say thanks to parts select, had the part, fast shipping, great job, thank you.
Was this helpful?
Thank you for voting!
defrost thermostat was open most of the time and didn't let the defrost element heat up.
9 of 13 people
found this instruction helpful.
-
Elvin from Gardner, KS
- Easy
- 15 - 30 mins
-
Nutdriver
Removed evaporator cover, unplug 2 wires to thermostat, unclipped it from the coil. Installed new themostat back the same way.
Was this helpful?
Thank you for voting!
Broken fan blade
7 of 8 people
found this instruction helpful.
-
Venita from MENA, AR
- Very Easy
- Less than 15 mins
-
Screw drivers
Followed video instructions which were to unplug refrigerator, on lower back use screwdriver, loosen 4 screws, take off plastic cover, pull out fan, replace with new fan, replace cover and 4 holding screws, plug in refrigerator. I am female, 77 years old and if I can do it, anyone can.
Was this helpful?
Thank you for voting!
Freezer compartment warm / Ice cream soft
9 of 15 people
found this instruction helpful.
-
George from McBee, SC
- Really Easy
- 15 - 30 mins
-
Nutdriver, Socket set
I worked for GM as a Frigidaire Tech, before starting my own business. I have retired now.
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. [email protected]
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. [email protected]
Was this helpful?
Thank you for voting!
Would not run. Everything in the freezer was spoiled.We were on vacation when it happened so we didn't know we had a problem until we got home. Big mess.
6 of 6 people
found this instruction helpful.
-
Sonya from PUNTA GORDA, FL
- Really Easy
- 15 - 30 mins
-
Screw drivers
I knew from a problem years ago that the Thermostat was the likely cause so I ordered a new part and replaced it. Only need a phillips head screwdriver to remove the part and add the new one..
Was this helpful?
Thank you for voting!
Squealing noise and bottom half of freezer only froze
6 of 6 people
found this instruction helpful.
-
Walter from SALT LAKE CTY, UT
- Really Easy
- 30 - 60 mins
-
Screw drivers
I removed the shelves, unscrewed the cover panel of the fan motor and regulator dial, disconnected the fan motor from power, unscrewed 2 screws holding the motor to the mounting bracket and put the new motor in it's place. New motor had no thread in the mounting holes, so I put new tread in so I could use the 2 screws. Another option woul
... Read more
d have been to drill all the way through the mounting holes and use longer screws or bolts. Of course I turned the power off before I started repairs. Freezer runs like new now. Technicians wanted $400 for the job, while it cost me a mere $55 for the Motor.
Read less
Was this helpful?
Thank you for voting!
The freezer was not keeping food frozen
6 of 7 people
found this instruction helpful.
-
Jeffry from VERONA, WI
- Easy
- 1- 2 hours
-
Screw drivers
I replaced the timer and the defrost thermostat. The defrost thermostat replacement was almost exactly like the training video here. The old part attached slightly differently. The most time consuming part was thawing out the heat exchanger, which was completely covered with ice, inside and out.
Compared to the training video, ... Read more the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Compared to the training video, ... Read more the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Freezer was freezing solid
6 of 7 people
found this instruction helpful.
-
Matt from Cincinnati, OH
- Easy
- Less than 15 mins
-
Pliers
I first replaced the defrost timer about a week prior and it did not correct the problem. I then ordered the thermostat from partselect and within 15 minutes had the part installed. My refridgerator has been running correctly for a couple weeks.
Was this helpful?
Thank you for voting!
Freezer wouln't start
7 of 11 people
found this instruction helpful.
-
Ivette from Grand Island, NY
- Really Easy
- Less than 15 mins
-
Screw drivers
First I removed the clamp, pulled out the part, and diconnected the two wires on the side and a small screw. Reconnected the new part with the small screw, connected the wires and plugged the part back to the side of the motor. Whaa La, Done.
Was this helpful?
Thank you for voting!