MW42 Microwave - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
microwave oven blew fuse
27 of 43 people
found this instruction helpful.
-
tad from tamarack, MN
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
First I removed upper front grill by removing two Philips head screws on top and pulling off. This exposed the Philips head screw which holds control panel in place. After removing screw I pushed up on panel and it came off to expose fuse. With needle nose pliers I removed old fuse and again with pliers held new fuse in position. With th
... Read more
e help of a bladed screwdriver, I pushed new fuse into holder, then replaced panel, screw and grill. This took less than 15 minutes even as one of the wires on control panel pulled out of connection and took some time to locate where to reconnect, otherwise was an easy fix
.
.
Read less
Was this helpful?
Thank you for voting!
Buzzing noise, no heating of food
22 of 35 people
found this instruction helpful.
-
Ted from Hudson, NH
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Removed control panel, discharged HV capacitor. Removed old diode, tested to confirm failure. Replaced part. Other than the removal of the panel swapping the part was almost as easy as replacing a light bulb.
Was this helpful?
Thank you for voting!
microve stopped working
15 of 30 people
found this instruction helpful.
-
Denice from Montgomery, AL
- Really Easy
- 15 - 30 mins
Jenn-Air Microwave would not turn on. Clock worked , light worked, timer worked and would count down .I changed' Part #0813140 Switch, Micr} cost $8.99 plus shippingNow it works Thank You for good advise
Was this helpful?
Thank you for voting!
Appears to work, but food not heated
20 of 48 people
found this instruction helpful.
-
Joel from CAMBRIDGE, MA
- Difficult
- 1- 2 hours
The high voltage tired was shorted. I replaced it with a new one, but that did not solve the problem.
You can test the high voltage tired with a voltmeter and a 9 V battery. Search Search for it on YouTube.
You can also test the high voltage capacitor, the high-voltage transformer, and the magnetron with a multi met ... Read more er. Search for the procedures on YouTube.
I tested all these high-voltage components with a low-voltage multi meter, and they all checked out OK (after replacing the diode). However the microwave still did not heat food.
When working on a microwave it is important to unplug it and also discharge the high voltage capacitor. The capacitor has a 10 megaohm resister to automatically discharge itself, but it may have failed – – so discharge it manually.
In the end I ordered a new microwave.
You can test the high voltage tired with a voltmeter and a 9 V battery. Search Search for it on YouTube.
You can also test the high voltage capacitor, the high-voltage transformer, and the magnetron with a multi met ... Read more er. Search for the procedures on YouTube.
I tested all these high-voltage components with a low-voltage multi meter, and they all checked out OK (after replacing the diode). However the microwave still did not heat food.
When working on a microwave it is important to unplug it and also discharge the high voltage capacitor. The capacitor has a 10 megaohm resister to automatically discharge itself, but it may have failed – – so discharge it manually.
In the end I ordered a new microwave.
Read less
Was this helpful?
Thank you for voting!
Microwave stopped working - would not heat up
11 of 21 people
found this instruction helpful.
-
louis from PARRISH, FL
- Easy
- 1- 2 hours
-
Pliers, Screw drivers
I removed the outer cover and exposed the inner workings. I watched a video on partselect.com to show how to remove and replace the Diode. I followed the instructions and it was very easy to replace.
Unfortunately, the diode was only part of the issue. I ended up replacing the High Voltage capacitor and Magnetron also. Those w ... Read more ere a little more complicated but still easy to do.
Now the Microwave works just like new! Cost me less than $100 for all parts.
Unfortunately, the diode was only part of the issue. I ended up replacing the High Voltage capacitor and Magnetron also. Those w ... Read more ere a little more complicated but still easy to do.
Now the Microwave works just like new! Cost me less than $100 for all parts.
Read less
Was this helpful?
Thank you for voting!
light bulb in water ice freezer door went bad
8 of 14 people
found this instruction helpful.
-
Carl from RIVERSIDE, CA
- Very Difficult
- More than 2 hours
-
Screw drivers
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this helpful?
Thank you for voting!
Died while heating lasagna
9 of 17 people
found this instruction helpful.
-
connie from madison, NC
- Really Easy
- Less than 15 mins
Removed 4 small star head screws from back of microwave, lifted body off, removed blown fuse and replaced with new one (found where cord enters). This model is stainless inside and out and I like it a lot. It is also sold by Daewoo and a few other manufacturers.
Was this helpful?
Thank you for voting!
Microwave went pop and nothing would work.
6 of 8 people
found this instruction helpful.
-
Deborah from STRUM, WI
- Easy
- 30 - 60 mins
-
Screw drivers
I mistakenly thought I had to remove the microwave to get to the back, not so. I would have had access to what I needed to unscrew; but I have to admit the hassle of taking it down and putting it back equals having to work on it attached to the shelf-your call on how you do this. I unscrewed the front top to remove the vent piece that
... Read more
is across the top front of the microwave. This will reveal the control panel screw. (While you have the vent removed you might want to clean the vent and the exposed filter.) carefully lift and pull out control panel. I unplugged a piece as the wires were tied tight. It will not completely detach, so carefully tip it back from exposed insides. The fuse is not clear but white with silver ends so look in upper right for it. I popped it out and replaced it. Replugged the wired part to cover and carefully fit tabs in and slide down to secre. Replace screw, replace vent piece and secure screws on top of microwave. I plugged it in to test before putting it back above my stove.
Read less
Was this helpful?
Thank you for voting!
Turntable Quit
5 of 7 people
found this instruction helpful.
-
RICHARD from OKLAHOMA CITY, OK
- Really Easy
- Less than 15 mins
-
Screw drivers
Snipped four corners off inspection panel,removed one phillips screw and two elect. Connections. Reverse process.
Was this helpful?
Thank you for voting!
No power to any microwave functions
2 of 2 people
found this instruction helpful.
-
Richard from CALIFORNIA, KY
- Really Easy
- 15 - 30 mins
-
Screw drivers
Access is via RT. SIDE Panel as you face microwave. There are three screws on the bottom right edge to loosen. After that the side panel slips down and off. the fuse is located in the rear near where the power cord comes in. It is the white ceramic tube 1/4" in dia. and 1-1/2" long. Pull it out like any fuse and replace with new one.
... Read more
Reassemble and you are done!
Read less
Was this helpful?
Thank you for voting!
tray glass floor broke
4 of 8 people
found this instruction helpful.
-
Eduardo from baltimore, MD
- Really Easy
- 15 - 30 mins
Remove old tray, clean old caulk, and clean inside of microwave, Place new tray-glass floor and caulk with heat resistant silicone. Easy project.
Was this helpful?
Thank you for voting!
broken tray-glass floor of microwave
3 of 5 people
found this instruction helpful.
-
ted from lagrange, KY
- Really Easy
- 15 - 30 mins
very simple job. removed broken tray, inserted new tray and caulked around edges with a high heat resistant caulk.
Was this helpful?
Thank you for voting!
Replacing the bulb in the freezer side
5 of 11 people
found this instruction helpful.
-
Yafa (and David) from Bothell, WA
- Easy
- Less than 15 mins
-
Nutdriver
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Was this helpful?
Thank you for voting!
Magnetron shorted out blowed 15 amp fuse
3 of 8 people
found this instruction helpful.
-
Duane from Jacksonville, FL
- Very Easy
- 1- 2 hours
-
Screw drivers, Socket set
removed cover of microwave, replaced fuse checked for short at plug with volt ohm meter, there was a short at the plug then checked magnetron for short and there was a short at the magnetron, the cap and diode checked good.
replaced magnetron IT IS WORKING GREAT !!
replaced magnetron IT IS WORKING GREAT !!
Was this helpful?
Thank you for voting!
burned oven bulb
3 of 9 people
found this instruction helpful.
-
Ivanka from Atlantra, GA
- Really Easy
- 30 - 60 mins
-
Pliers, Screw drivers
The hardest part was taking out original light bulb because screws on shield where hard to unscrew after all this years . The old bulb vent out leaving neck in socket. It took narrow electrical pliers to get neck out .The generic appliance bulb did not fit and had aluminum neck ,not recommended for brass sockets in ovens.Putting new ligh
... Read more
t bulb in was not the problem.
Read less
Was this helpful?
Thank you for voting!