Microwave worked intermittently depending on how door was closed
67 of 85 people found this instruction helpful.
  • Robert from Bainbridge Island, WA
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Screw drivers
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and a lso took a while to figure out that there is a plastic rod that inserts through the hole in the switch body. Once i figured this out went like a breeze. Lower horizontal switch was the bad one, but since the kit came with two switches i went ahead and replaced the upper horizontal one as well. IT appears that the horizontal switches are probably more likely to fail than the vertical switch based on the position of the switch and force angles. Works great now!
Was this helpful?
Thank you for voting!
Microwave went dead while in use.
35 of 42 people found this instruction helpful.
  • Keith from Georgetown, TX
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
1. removed vent across the top to gain excess to Screw holding control in place. 2. Removed control panel to access Fuse. 3. Remover fuse after pulling plug. 4.Tested fuse for continuity with volt ohm meter noting no continuity.5. Orderd new fuse. 6. receeived new fuse and installed infuse holder.7. plugged microwave plug back in receptic al and tested unit now working OK.Reversed steps 2 & 1 job complete
Was this helpful?
Thank you for voting!
Buzzing noise, no heating of food
22 of 35 people found this instruction helpful.
  • Ted from Hudson, NH
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
Removed control panel, discharged HV capacitor. Removed old diode, tested to confirm failure. Replaced part. Other than the removal of the panel swapping the part was almost as easy as replacing a light bulb.
Was this helpful?
Thank you for voting!
Close the door on the microwave, punch in the # nothing happened
15 of 23 people found this instruction helpful.
  • Robert S. from Stafford, TX
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I removed the unit from the wall. Took the cover off. Set the unit on its side. It revealed the working parts. Removed the old micro switches. Put in the new oness. Presto, it worked. Very easy for me.
The parts was delivered almost before my notice they were shipped.
Was this helpful?
Thank you for voting!
Needed to push door up to run appliance.
15 of 28 people found this instruction helpful.
  • J Patrick from Baltimore, MD
  • Easy
  • Less than 15 mins
  • Pliers, Screw drivers
1. Removed cabinet screws (10-15?). 2. Removed cabinet. 3. Removed top interlock switch which actually was not defective. The press clip connection appeared as if it had been arcing for quite some time and the corrosion created resistance sufficient to prevent the current from getting through the switch. 4. Replaced switch anyway but brok e plastic retaining clip despite every effort not to do so. Reset broken clip with super glue. 5. Reassembled cabinet and appliance is in good working condition.
Was this helpful?
Thank you for voting!
Fan motor and magnetron did not come on, but every thing else did.
11 of 16 people found this instruction helpful.
  • Dale from Chester, CA
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
Problem would come and go. Found service schematic inside unit. Perform all the suggested tests. One possible solution was the primary interlock switch shown on the schematic and a check found the switch stuck. It would free up some times but would stick again in the open position. Ordered switch which was a simple plug in unit.
Was this helpful?
Thank you for voting!
Microwave stopped working - would not heat up
11 of 21 people found this instruction helpful.
  • louis from PARRISH, FL
  • Easy
  • 1- 2 hours
  • Pliers, Screw drivers
I removed the outer cover and exposed the inner workings. I watched a video on partselect.com to show how to remove and replace the Diode. I followed the instructions and it was very easy to replace.

Unfortunately, the diode was only part of the issue. I ended up replacing the High Voltage capacitor and Magnetron also. Those w ere a little more complicated but still easy to do.

Now the Microwave works just like new! Cost me less than $100 for all parts.
Was this helpful?
Thank you for voting!
Appears to work, but food not heated
20 of 48 people found this instruction helpful.
  • Joel from CAMBRIDGE, MA
  • Difficult
  • 1- 2 hours
The high voltage tired was shorted. I replaced it with a new one, but that did not solve the problem.

You can test the high voltage tired with a voltmeter and a 9 V battery. Search Search for it on YouTube.

You can also test the high voltage capacitor, the high-voltage transformer, and the magnetron with a multi met er. Search for the procedures on YouTube.

I tested all these high-voltage components with a low-voltage multi meter, and they all checked out OK (after replacing the diode). However the microwave still did not heat food.

When working on a microwave it is important to unplug it and also discharge the high voltage capacitor. The capacitor has a 10 megaohm resister to automatically discharge itself, but it may have failed – – so discharge it manually.

In the end I ordered a new microwave.
Was this helpful?
Thank you for voting!
Cooking rack support melted
6 of 6 people found this instruction helpful.
  • Ernie from Collinsville, IL
  • Really Easy
  • Less than 15 mins
  • Pliers
Just pulled the old support out with pliers and installed the new one which snaps in. Not sure why the support melted as it has been the same one twice now. Keep extra support clips on hand, but no need as Parts Select had the new ones here next day.
Was this helpful?
Thank you for voting!
Would not start
2 of 3 people found this instruction helpful.
  • LENNARD from BURNSVILLE, MN
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
Watched a you tube video prior to installing new switch. Followed the video which gave me confidence i was up to the task. After removing the touch pad I found my design was not exactly like the you tube model but I found the defective switch, replaced it and put the microwave back together. Works great. Again watch the videos
Was this helpful?
Thank you for voting!
One of the shelf plastic holder was broken
3 of 8 people found this instruction helpful.
  • Craig from Swansea, MA
  • Easy
  • Less than 15 mins
  • Pliers
I was able to find the part on line and within a few days received the part and installed it with no problems thanks to the website drawing information.
Was this helpful?
Thank you for voting!
support clip broke of that holds the wire rack
1 of 2 people found this instruction helpful.
  • William from Hamburg, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Just pushed in a new clip which was very easy.
Excellent service. Only took 3 days from Calf.
Was this helpful?
Thank you for voting!
Microwave would not cook
  • Scott from Mickleton, NJ
  • Easy
  • Less than 15 mins
  • Screw drivers
All the electrics worked on Amana microwave EXCEPT for the cooking function. Inspected the control board and found the upper switch on the door interlock was burnt. Installed new switch in minutes and everything now works fine. Unfortunately, had to purchase expensive two switch "kit" although only one switch was kaput. PartsSelect mai ling was SUPER fast. Thanks for looking, Scott
Was this helpful?
Thank you for voting!
motor would start by itself when door closed
  • Lewis from Loveland, CO
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
remove 4 screws from top, front louvered panel snaps out. remove 1 screw from top of keypad, keypad pivot's forward and can be removed. There is a white mounting bracket inside left. Remove two screws, one top and one bottom, bracket lifts up and out. 3 sets wires are attached, mark them with masking tape, top, center, bottom and pull out plugs. They can only attach one way. Using a very small screw tip, lift plastic latch from switch, it rotates out and is removed from the pivot pin. reassemble in reverse order after switches are replaced
Was this helpful?
Thank you for voting!
Microwave worked intermittently
  • Robert from Palmer Lake, CO
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Screw drivers
The door was not engaging the micro switches properly no doubt from 10+ years of wear. The upper switch removed fairly easily but take care not to tweak the plastic brace too much or it will snap. The lower one was the tricky one. After much examination I noticed that the trick to remove it was underneath the brace. Take a butter knife (n o joke) and insert it just under the old micro switch and gently press down twisting the micro switch every so slightly til it releases. The replacements snap back in with no trouble. The microwave is working much better now, though not perfect.
Was this helpful?
Thank you for voting!