MRS22WI Frigidaire Refrigerator - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
my old ice maker leaked at the bottom
7 of 9 people
found this instruction helpful.
-
harry from terre haute, IN
- Really Easy
- Less than 15 mins
-
Nutdriver
it was really easy changing the ice maker. the only trouble i had was the wiring. it was very stiff and hard to route. it did not work at first but that was my fault did not have the connector plugged in all the way.since then it works great.
Was this helpful?
Thank you for voting!
Original Ice Maker quit working.
6 of 6 people
found this instruction helpful.
-
Gary from Azle, TX
- Really Easy
- 30 - 60 mins
-
Nutdriver
Loosened the 2 screws a little so that it would slide up and off then unplugged the wire harness.
Installed the new one in reverse order and works like a champ.
Installed the new one in reverse order and works like a champ.
Was this helpful?
Thank you for voting!
Excessive ice formation on cooling coils of the freezer section led me to believe that air must be finding its way into the freezer section, which led me to think that the freezer section was not adequately sealed.
6 of 6 people
found this instruction helpful.
-
RODRIGO from UNCASVILLE, CT
- Easy
- 1- 2 hours
-
Screw drivers
Ordered gasket and gasket arrived within 48 hrs. Put the unit into out-of-commission status. Defrosted cooling coils. Dried the coils thoroughly. Reinstalled cover panel to the coils. Removed existing door gaskets. Installed new (2) gaskets. So far ice buildup to the coils had ceased.
Other Parts Used:
Was this helpful?
Thank you for voting!
freezer cold other side for milk warm
8 of 13 people
found this instruction helpful.
-
Thomas J from Dawsonville, GA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers, Wrench set
the heater defroster was bad. tested and no continuity brake in eliment.just doing a visual might have detected it but it`s hidden behind the coils.....all is working now
Other Parts Used:
Was this helpful?
Thank you for voting!
Frequent dripping on floor and no cycling of compressor
6 of 7 people
found this instruction helpful.
-
Edward from DELAND, FL
- Easy
- Less than 15 mins
-
Nutdriver, Pliers
After posting the specific symptoms and getting feedback, I had narrowed the cause to two linked parts. I ordered both intending to replace first one, then the other as needed. With parts in hand, I pulled off the freezer control knob, used a nut driver to remove the two panel securing screws (behind the face, against the inner ceiling) a
... Read more
nd gently dropped the cover down. The control (temp sensor and cold control) is easily accessible as it sits wedged into two slots in the plastic cover. The control must be slightly lifted in order to extract the long sensor that attaches to the control and runs under it and into a plastic sleeve behind the panel (the new control comes with the sensor wrapped in a tight coil and it must be unwound for the install). Removed the three wires noting which color goes where. Used needle-nose pliers to remove the small push-on tabs and removed the control. After starting the new sensor probe into the sleeve re-attached the 3 wires to the new control. Used the original as a model for how to pre-bend the probe for the first 2 inches as it was mildly frustrating to position the unit back correctly. Pushed everything back into place, re-installed the screws and plugged the fridge back in...(you DID unplug it first, right?). Still haven't used the second part (defrost timer), but I expect it to go soon...it is a 17 year old refrigerator, after all.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Freezer frosted up
6 of 7 people
found this instruction helpful.
-
Gregg from Mohnton, PA
- Really Easy
- 15 - 30 mins
-
Screw drivers, Wrench set
Removed old thermostat and replaced. really easy.
Was this helpful?
Thank you for voting!
Coils freezing up and refrigerator would get warm
6 of 7 people
found this instruction helpful.
-
Richard from Scranton, KS
- Easy
- 15 - 30 mins
-
Nutdriver
Wasn't sure if it was the derost timer or the heating element. Since the timer was much cheaper, I bought it and crossed my fingers.
My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring.
Succe ... Read more ss! My coils no longer freeze up.
Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring.
Succe ... Read more ss! My coils no longer freeze up.
Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
Read less
Was this helpful?
Thank you for voting!
I replaced the icemaker
5 of 5 people
found this instruction helpful.
-
Michele from Smithfield, UT
- Easy
- 15 - 30 mins
-
Nutdriver
I removed the two screws and unplugged it. I then attached the pigtail to the appliance, then to the fridge. I had to push the excess wire harness into the hole in the back. It took a few minutes to move the rest of the harness out of the way by curving it upward and securing it with a nylon tie.I ordered the ice maker from Part Select on
... Read more
Sunday night and it arrived at 8:32 Tuesday morning, THANK YOU! I ordered very simple weed cutter parts from Sears a week ago and they haven't even shipped yet!
Read less
Was this helpful?
Thank you for voting!
coils freezing refrigerator not cooling
7 of 11 people
found this instruction helpful.
-
Else from Plant City, FL
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
The defrost timer is located under the freezer side behind the lower plastic cover. Very simple, just 2 screws and a plug, and your done.
The thermostat requires removing the lower drawers in the freezer and unscrew the back side of the rails and let them hang over to get access to the lower cover on the back of the freezer. On ... Read more ce the panel is off you will be able to see the thermostat. From there you just remove the thermostat from the clip, cut the 2 wires, splice in the new thermostat and re install using the new clip and your done!!
This was my first time and it was really simple. I had a local repair shop quote me $375.00 . I did it myself for under 50.00 shipped to my door..
The thermostat requires removing the lower drawers in the freezer and unscrew the back side of the rails and let them hang over to get access to the lower cover on the back of the freezer. On ... Read more ce the panel is off you will be able to see the thermostat. From there you just remove the thermostat from the clip, cut the 2 wires, splice in the new thermostat and re install using the new clip and your done!!
This was my first time and it was really simple. I had a local repair shop quote me $375.00 . I did it myself for under 50.00 shipped to my door..
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Freezer was getting a build up of frost on the condenser and wasn't cooling.
5 of 5 people
found this instruction helpful.
-
Arthur from Lithonia, GA
- Really Easy
- 15 - 30 mins
-
Nutdriver
First I remove the back panel which had 4 screws. Then I removed the ice maker. The icemaker is held in place by the 2 screws that requires backing the screws out just a litter, than lift up and remove the electrical connector. Used a volt ohm meter to check the resisitant in the heater element and the defrost timing switch. Both tested
... Read more
good and that left only the thermostat. Removed and replaced the thermastat swich. I cut the ends of the old switch and crimp the ends of wire with the crimps that came with the swict i purchased from parts select. My refrigerator is working properly and making ice like normal.
Read less
Was this helpful?
Thank you for voting!
water did not reach ice maker
6 of 8 people
found this instruction helpful.
-
Carolyn from Crab Orchard, TN
- Really Easy
- 15 - 30 mins
-
Pliers, Screw drivers
We replaced the water control valve. We took the old one out and put the new one in. We primed it and then it took off.
Was this helpful?
Thank you for voting!
Replace ice maker which was splashing water
5 of 5 people
found this instruction helpful.
-
John from PHOENIX, AZ
- Really Easy
- 15 - 30 mins
-
Screw drivers, Wrench set
Turn off ice maker
Slide wire harness shield off connector
Disconnected harness
Loosened 2 wall screws
Remove old ice maker
Installed new one reversing process
Slide wire harness shield off connector
Disconnected harness
Loosened 2 wall screws
Remove old ice maker
Installed new one reversing process
Was this helpful?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
5 of 5 people
found this instruction helpful.
-
Bruce from MARTINEZ, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to ... Read more uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to ... Read more uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Read less
Was this helpful?
Thank you for voting!
Ice maker stopped working (Very oxidized residue)
8 of 14 people
found this instruction helpful.
-
Robert from Woodstock, IL
- Really Easy
- Less than 15 mins
-
Nutdriver
I removed the old ice maker and unplugged the cable. Screwed in the new one with a 1/4 nut driver at the 2 mounting screws, plugged cable in. Checked ice maker with a small level before final. All Ok and after night I had Ice and it has been working great since.
Was this helpful?
Thank you for voting!
replaced door racks
5 of 6 people
found this instruction helpful.
-
Yvonne from Sayre, PA
- Really Easy
- Less than 15 mins
Placed door rack in end caps and snapped on to door
Other Parts Used:
Was this helpful?
Thank you for voting!