plastic gear broke off - cubes not getting kicked out
23 of 25 people
found this instruction helpful.
-
Laurence from Middleton, WI
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
removed the three screw holding the broken unit - pulled off the old module.
Before I could install new module I had to loosen some fasteners on ice maker so I could turn shaft to align with new module.
Then push on new unit and three screws. Had tumbling ice in about an hour. My wife thinks I'm a hero. (I am)
Before I could install new module I had to loosen some fasteners on ice maker so I could turn shaft to align with new module.
Then push on new unit and three screws. Had tumbling ice in about an hour. My wife thinks I'm a hero. (I am)
Was this helpful?
Thank you for voting!
No water to icemaker
27 of 37 people
found this instruction helpful.
-
McManus from Palm Coast, FL
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
Unplug refridge, shut off water supply, remove backing. Remove two screws holding in valve, pull out valve and remove water lines. Have towel to wipe up very little water that leaks out. Unplug electric sources, remove old valve. Take new valve , plug in electric sources, push in water supply until they bottom out, attach bracket to back
... Read more
of refridge. Replace backing, turn on water supply, plug in and bleed lines.
Read less
Was this helpful?
Thank you for voting!
Refrigerator door failing to close without being pushed shut
25 of 32 people
found this instruction helpful.
-
Kenneth from Greeley, CO
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Pliers
Replaced upper cam piece on bottom hinge and also replaced pivot thimble on upper hinge.
No problems, except pivot thimble glued in place. Had to cut up and pull out with pliers. Everything works like new now.
No problems, except pivot thimble glued in place. Had to cut up and pull out with pliers. Everything works like new now.
Other Parts Used:
Was this helpful?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
22 of 23 people
found this instruction helpful.
-
W from Nellysford, VA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also uns
... Read more
crewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Read less
Was this helpful?
Thank you for voting!
Just a trickle of water to icemaker and water dispenser
22 of 24 people
found this instruction helpful.
-
Bill from Hot Springs Village, AR
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Wrench set
Turned refrig off, pulled it out for access to the valve, unplugged refrig and turned off water supply to the outlet valve. I made the installation a bit more difficult by over tightening the supply line connection which ruined the brass compression washer. I replaced it with a plastic compression washer which is probably better since t
... Read more
he supply line is plastic. The electrical connections were very simple. I was just guessing the old outlet valve was bad since I had checked the filter. After replacing the valve, the ice maker and water dispenser work like new on a 17 year old refrigeration. Also, I was very pleased with fast processing and delivery of the order.
Read less
Was this helpful?
Thank you for voting!
in door water dispenser tube broken off 1.5 inches from end
23 of 27 people
found this instruction helpful.
-
haig from La Quinta, CA
- Really Easy
- 15 - 30 mins
-
Pliers, Wrench set
shut off water supply behind fridge then released trapped water pressure in the line at the dispenser. Locked off dispenser controls (push button switch). Removed nozzle retaining screw and pulled out nozzle approx. 3 in. to cut off tubing at black pipe so as to use the old pipe as a guide/pull (fish) for the new pipe by joining the end o
... Read more
f the new nozzle to the cut and of the old pipe with electrical tape.Then pulled the old pipe from bottom of fridge while simultaneously feeding/pushing new pipe from top. I had to remove lower grate on fridge to access the pipe on bottom. Remaining coupling connection on bottom was done by hand to avoid stripping plastic coupling.
Read less
Was this helpful?
Thank you for voting!
Ice maker would run but not dispense ice
22 of 24 people
found this instruction helpful.
-
Gary from HILLSBORO, OR
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Removed the ice bin and turned it over. Removed the old coupling and replaced with the new one, reusing the screw that holds it in place. Then removed the cover plate over the drive shaft that comes out of the door. Pulled out the old shaft and removed the plastic ring that keeps stuff from falling into the motor area. Put the ring onto t
... Read more
he new shaft and slowly put the new shaft down into the door until it seated in the motor assembly. Replaced the cover plate with the nut driver and voila! The Ice Age has returned. An easy fix once I determined that the drive shaft end was worn where it engages the coupling, causing it to slip and not move the ice dispenser arm.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Refrigerator came with house my daughter purchased and needed new seals. Refrigerator is 17 years old.
23 of 28 people
found this instruction helpful.
-
Barb from North Royalton, OH
- A Bit Difficult
- 1- 2 hours
-
Nutdriver
First, I read your instructions on line about how to replace a refrigerator gasket and freezer gasket. We replaced both. The information was extremely helpful since we had never done this before. We then loosed a few screws at a time starting with the outside door corner and worked our way around, replacing the seal as we took off the
... Read more
old seal. Leaving the old seal on as we worked our way around gave us the clearance we needed to insert the new gasket behind the metal plate which holds the gasket to the door. Your easy to use web site made ordering easy and delivery was unbelievably fast. Thanks.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
ice distribution door broke
23 of 28 people
found this instruction helpful.
-
David from Winston-Salem, NC
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
At their site was ordering each piece by # and cost and it was adding up to be costly. Went to partselect and was doing the same and up pops the ice door kit. Was a little wary because my original had a heater tape to it. Got the kit and installed not a problem at all. 100% satisfied would recommend to anyone.
Was this helpful?
Thank you for voting!
Ice dispensor motor would run but would not dispense ice at the door!
22 of 26 people
found this instruction helpful.
-
Larry from Hague, ND
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Wrench (Adjustable)
To get the coupler off the motor shaft I took two adjustable wrenches and slit the old coupler where it was cracked.The threads on the motor shaft were stripped closest to the motor.I took two thin washers and put them on the motor shaft so the new coupler would not turn down to where the threads on the motor were sripped.Since the thread
... Read more
s on the coupler are left hand they keep the coupler tight as the motor turns the dispenser auger to dispense the ice.I was a bit difficult to unplug the wiring harness but got it after we used a screwdriver to keep the tab bent down until the harness was unplugged.
Read less
Was this helpful?
Thank you for voting!
Plastic Water Spout Broke Off
21 of 23 people
found this instruction helpful.
-
Michael from Colorado Springs, CO
- Difficult
- More than 2 hours
-
Nutdriver, Pliers, Screw drivers, Socket set
Turn off water supply line fridge. Removing front panel is a must to allow acces to spout and water line. Be careful not to crack front panel $90, it snaps in from the botton, slide a stiff putty knife along bottom edge and gently pry outward to remove. Remove 2 screws that hold spout in place, then cut water line right behind spout. The
... Read more
tricky part is fishing water line down through door. You need to splice new line to old with double sided screw or something with threads that will prevent the lines from pulling apart, then pull water line from bottom of door by hinge, very tight when pulling through hinge opening. You will need to remove vented dust cover at botton of doors to acces the water line. The line has a threaded coupling so unscrew and drain water then cut new line to length. There is a small metal insert in old line that needs to be removed and inserted into new line before attaching coupler. I could perform this in half the time now that I have done it once.
Read less
Was this helpful?
Thank you for voting!
Ice dispenser freezing up, dispenser door not closing completely.
22 of 26 people
found this instruction helpful.
-
Robert from Valencia, CA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
First off, if you have the stainless steel panel inserts on your refrigerator you'll need to remove those to do this repair. I kept looking for the access holes on the underside of the dispenser panel that you're supposed to insert a screwdriver into to pry it off. It wasn't until I removed the freezer door handle, slid the lower stainles
... Read more
s panel insert out, and removed the rail just beneath the dispenser that I could see and access these holes. I also removed the upper stainless panel and rail just above the dispenser to allow enough movement get the dispenser cover off and out. The rest of the repair is pretty straightforward. The old ice door was beaten up and not closing completely, this was letting warm air into the freezer which was melting and re-freezing. This kit fixed the problem.
Read less
Was this helpful?
Thank you for voting!
Refrigerator stop cooling
23 of 29 people
found this instruction helpful.
-
kelly from glen allen, VA
- Really Easy
- Less than 15 mins
-
Screw drivers
I was about to waste $1000 on buying a Refrigerator. Took 1 mins to search on google "Refrigerator doesn't work". Found a video on youtube, showed a step and step video to solve my problem. Order the part $50 and it took me less then 5 mins to install it. =)
Was this helpful?
Thank you for voting!
The old motor wouldn't turn the fan.
24 of 32 people
found this instruction helpful.
-
Bob from Hesston, KS
- Easy
- 15 - 30 mins
-
Socket set, Wrench set
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Remova
... Read more
l of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Read less
Was this helpful?
Thank you for voting!
Ice Magic Plus stopped making ice
25 of 35 people
found this instruction helpful.
-
George from Hammond, LA
- Really Easy
- Less than 15 mins
-
Screw drivers
First I removed the icemaker from the freezer by removing two horizontal screws holding it to the side wall, and one vertical screw holding the front to a bracket coming off the side wall. Then I used a flat screwdriver to unlock the electrical plug. (After doing this, I realized that this wasn't necessary at all, and this part could have
... Read more
been changed just as easily without removing the icemaker.) On the front, there is a white cover with Ice Maker Plus. Use a flat screwdriver to unlock the tangs and remove the cover. There are three screws in the corners that once removed, will allow the motor assy. to be gently pulled straight out. On the back of the part, you will see many gold lands that the timer touches. I don't think there was anything wrong with my motor. I had two spots where the gold plating was worn off, so I suspect it was not making contact, and the whole process would stop. Slide the new part in place making sure the teeth on the gears line up (not a big deal), and secure with the screws. Install cover and you're done. Mine has been making ice like it was brand new.
Read less
Was this helpful?
Thank you for voting!