Broken center crisper rail
1 person
found this instruction helpful.
-
Neil from WILMINGTON, MA
- Very Easy
- Less than 15 mins
Lift off glass shelf and insert tabs of rail on each end , replace shelf.
Was this helpful?
Thank you for voting!
Ladder hook for shelves broke.
1 person
found this instruction helpful.
-
Helene from Matawan, NJ
- Very Easy
- Less than 15 mins
Hook just clips right into the channel in seconds.
Was this helpful?
Thank you for voting!
freezer and refrigerator compartments not cold enough
1 person
found this instruction helpful.
-
Michael from Colorado Springs, CO
- Really Easy
- Less than 15 mins
-
Nutdriver
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
Was this helpful?
Thank you for voting!
Plugged it in.
1 person
found this instruction helpful.
-
Adam from GLOVERSVILLE, NY
- Really Easy
- Less than 15 mins
-
Nutdriver
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
Was this helpful?
Thank you for voting!
The control indicators would flash and buzzing noise came from the controler
1 person
found this instruction helpful.
-
John from JACKSON, MS
- Really Easy
- 15 - 30 mins
-
Screw drivers
Followed the video exactly as shown from the website. I do suggest using a mirror or your phone to visualize the notch to press to drop the cover.
Was this helpful?
Thank you for voting!
Freezer and refridgerator just stopped working.
1 person
found this instruction helpful.
-
Daniel F from CALEDONIA, MN
- Very Easy
- Less than 15 mins
-
Screw drivers
The Condenser Fan Motor was already removed due to searching for the problem. The new fan motor looked different from the original but I felt very comfortable that Part Select had sent me the new part showing original part number changing numbers over the years. Simply placed the fan blades onto the new motor lined up 2 of the holes pla
... Read more
ced screws and tightened then plugged the wire ribbon into the Condensor Fan Motor, plugged in the Refridgerator and it worked beautifully.
The instruction video on the Part Select Web Site made it so incredibly easy to install. Installation took under 3 minutes!
The instruction video on the Part Select Web Site made it so incredibly easy to install. Installation took under 3 minutes!
Read less
Was this helpful?
Thank you for voting!
compressor not running
1 person
found this instruction helpful.
-
Doug from Lancaster, CA
- Really Easy
- 15 - 30 mins
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
Was this helpful?
Thank you for voting!
The refrigerator was working for just 1 minute and breaks, I discovered that the fan was not working , I understood that there wsa something wrong with the condenser fan motor. I just order a new one.
1 person
found this instruction helpful.
-
John from PHOENIX, AZ
- Really Easy
- 15 - 30 mins
-
Nutdriver
The installation video for condenser fan motor helped a lot to know how to disconnect the old fan motor and connect the new one. So easy just know how to remove and put back the fan gently, observe carefully where is the center and the connector position; 15 min after everything was done and the unit works well to date.
Was this helpful?
Thank you for voting!
Noisy, running constantly motor in damper unit.
1 person
found this instruction helpful.
-
lawrence from TRAVERSE CITY, MI
- Really Easy
- 15 - 30 mins
Unsnapped and pulled off small cover exsposing two phillips head screws. I removed larger cover and styrofoam insert fully exsposing the damper unit. i unplugged same and with a 1/2 inch wood chisel was able to release the "snaps" holding the old unit in place. Simply reverse procedure to install new unit.
Was this helpful?
Thank you for voting!
Refrigerator was not cold.
1 person
found this instruction helpful.
-
Edward from Reading, AL
- Easy
- 15 - 30 mins
-
Screw drivers
Refrigerator was not cold.
I had this problem before and it was the control vale in the back of the refrigerator. I ordered it and change that out in 5 minutes. That wasn’t the problem. I had the repairman come over and within 5 minutes he told me what the problem was. He showed me where the control board was. He then wal ... Read more ked me through the removal process.
First remove the light cover on the Freezer & Refrigerator in front where the light button is located. Pull down on the front of the light cover. It pops out.
Second, in the front of the freezer & refrigerator temp control panel put your fingertips in front of the panel and pull down it’s hard to get the pins to release but the front pins will release, then pull down a little to allow the back hooks to release. (You can use a small common screwdriver if you can’t get it with your fingertips).
Next, once the panel is removed then disconnect the wiring harness. Then bring the panel to the counter, this is where you remove the circuit card and replace it. There are 4 hooks that hold the circuit board in place. Use a small common screwdriver to push the hooks away from the board. The new board comes as one piece. The board is perforated to allow you to snap the board. Directions come with the board and how to snap it. You will need to pay attention on how you removed the board. You will need to put the new board in the same way it came out.
Once the board is re-installed and lock into position reverse the process and install the control panel back into position.
Next is the programing of the board. Follow the directions that come with the control board and you will be back in business
This task took about 15 minutes to remove & replace and to program.
I had this problem before and it was the control vale in the back of the refrigerator. I ordered it and change that out in 5 minutes. That wasn’t the problem. I had the repairman come over and within 5 minutes he told me what the problem was. He showed me where the control board was. He then wal ... Read more ked me through the removal process.
First remove the light cover on the Freezer & Refrigerator in front where the light button is located. Pull down on the front of the light cover. It pops out.
Second, in the front of the freezer & refrigerator temp control panel put your fingertips in front of the panel and pull down it’s hard to get the pins to release but the front pins will release, then pull down a little to allow the back hooks to release. (You can use a small common screwdriver if you can’t get it with your fingertips).
Next, once the panel is removed then disconnect the wiring harness. Then bring the panel to the counter, this is where you remove the circuit card and replace it. There are 4 hooks that hold the circuit board in place. Use a small common screwdriver to push the hooks away from the board. The new board comes as one piece. The board is perforated to allow you to snap the board. Directions come with the board and how to snap it. You will need to pay attention on how you removed the board. You will need to put the new board in the same way it came out.
Once the board is re-installed and lock into position reverse the process and install the control panel back into position.
Next is the programing of the board. Follow the directions that come with the control board and you will be back in business
This task took about 15 minutes to remove & replace and to program.
Read less
Was this helpful?
Thank you for voting!
Refer lights not working, there are two lights and neither worked. Decided the switch was the problem.
1 person
found this instruction helpful.
-
John from AUBURN, CA
- A Bit Difficult
- 15 - 30 mins
-
Pliers, Screw drivers
The switch fix but did not fix the problem. I assumed the wires go on the same way as on the old switch. Is it possible if one light Burns out, the other will not work either?
Was this helpful?
Thank you for voting!
About twicw per year the freezer would ice up because the control board didn't activate the defrost element
1 person
found this instruction helpful.
-
Larry from GOLDEN, CO
- Really Easy
- 30 - 60 mins
-
Screw drivers
Removed the cover using a mirror to see how to release the clips on the rear side of the cover, removed the circuit board noting how everything was installed and also visually verified the part was the same. Broke the circuit at the designated score, installed and followed instructions for programming. All is well now.
Was this helpful?
Thank you for voting!
broken glass shelf
1 person
found this instruction helpful.
-
Nancy from LOUDON, TN
- Really Easy
- 30 - 60 mins
Replaced shelf, very simple
Was this helpful?
Thank you for voting!
Unit would not defrost
1 person
found this instruction helpful.
-
William from FAIRFIELD, VA
- Easy
- 30 - 60 mins
-
Screw drivers
I checked the element and the thermostat and determined the problem to be the control board. I simply followed the instruction in the video. Everything went well until the last step, the video said to push the freezer down button. When this did not work I refered to the written instructions which told me to push the up button. That did
... Read more
it. Job complete. The unit is working as it should.
Read less
Was this helpful?
Thank you for voting!
Lower freezer section was icing up, not defrosting properly. Repeated manual defrosting including disassembling did not solve the problem.
1 person
found this instruction helpful.
-
Robert from Meridian, ID
- Really Easy
- 30 - 60 mins
-
Screw drivers
Emptied and disassembled the freezer. Defrosted and dried the coils. Tested the defrost heater coil ( 50 ohms ) PRT and fan - all OK. Opened the lower back panel and cleaned the water collection tray. Vacuumed out all debris including coils underneath. Reassembled everything. Removed the old control board and installed the new board payin
... Read more
g attention to ESD steps. Applied AC power. Programmed the new board per the video link ( nicely done ). 3 weeks later and the unit seems dry and happy. Running at lower settings with good temperature results. Suspect the 24VDC relay activating the defrost heater coil on the control board or what controls the relay not working. May pull relay for test.
Read less