EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details
✖

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

JVM1190WY004 General Electric Microwave - Overview

Diagrams for JVM1190WY004

See every part. Know exactly what you need.

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Light Bulb - 40W 130V – Part Number: WB36X10003
$23.60
In Stock
Light Bulb - 40W 130V
★★★★★
★★★★★
(28)
Part #WB36X10003
This light bulb is a 40 watt, 130-volt clear appliance light bulb that is manufactured to fit microwaves with small-base light bulb sockets. The light bulb illuminates the inside of the microwave while the microwave is running. You may need to replace this part if the existing one is burnt-out or broken. If the existing light bulb is broken, disconnect power to the microwave and remove the bulb base with a pair of needle nose pliers. This is a common wear item, so it is recommended to order a spare. These light bulbs are sold individually.
Diode – Part Number: WB27X10597
$59.47
In Stock
Diode
★★★★★
★★★★★
(10)
Part #WB27X10597
This part allows power to go one way only.
Grease Filter – Part Number: WB6X60
$56.33
In Stock
Thermostat Cut-Out – Part Number: WB27X10195
$51.61
In Stock
Thermostat Cut-Out
★★★★★
★★★★★
(2)
Part #WB27X10195
Also known as Thermostat or Humidity Sensor for Fault Code.
Light Socket Screw – Part Number: WB01X10063
No Longer Available
Light Socket Screw
Part #WB01X10063
This screw is sold individually.
Door Handle – Part Number: WB15X10094
No Longer Available
Door Handle
Part #WB15X10094
Handle only.
Fuse – Part Number: WB27X10454
$21.95
In Stock
Fuse
Part #WB27X10454
High-Voltage Capacitor - 2100V – Part Number: WB27X10240
$100.27
In Stock
Magnetron – Part Number: WB27X10585
$59.47
In Stock
Magnetron
Part #WB27X10585
This part is used to generate microwave energy/heat.
Steam Sensor – Part Number: WB24X799
$150.57
In Stock
Motor Capacitor – Part Number: WB27X10170
$40.02
Special Order
Motor Capacitor
Part #WB27X10170
SMARTBOARD – Part Number: WB27X10227
No Longer Available
SMARTBOARD
Part #WB27X10227

Questions And Answers for JVM1190WY004

Ask our experts a question about this model and we'll get back to you as soon as possible!

Sort by:
  • 1
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
DALE - For model number JVM1190WY004
May 29, 2023
Microwave stop working. Replaced main fuse: slow blow 15A. Restored power, however the cooling fan (not the blower exhaust fan) continues to run. there's a flashing light of a microwave door on the panel. Two other thermal fuses DO HAVE CONTINUITY. The thermal fuse just below the main fuse shows NO CONTINUITY ... thank you in advance for your help.
Chris Boyle Profile
Hi Dale, thank you for reaching out. Based on the description that you have provided, we would recommend replacing the thermal fuse, part number PS239811, to fix this issue. We hope this solves your issue!
$27.95
In Stock
Thermal Fuse
1 person found this instruction helpful.
Was this helpful?
Thank you for voting!
  • 1

Common Symptoms of the JVM1190WY004

How this model fails, and the parts that fix it.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
bulb had broken off in base that was still screwed into socket
93 of 109 people found this instruction helpful.
  • william from san antonio, TX
  • A Bit Difficult
  • 15 - 30 mins
  • Pliers, Screw drivers
At first I tried to use pliers to unscrew the base,very uncomfortable working position,upside down and backwards(the microwave is installed over the range top)very limited space for your body and arms to manuver and you really cant see the base,all of this took place after the breaker was turned off ofcourse,finally figured out that you c an drop the entire bottom housing of the microwave by unscrewing 6 screws and the light sockets are easily accessable once you lower it,take out 1 retaining screw ,remove the entire socket and unscrewed the broken base and replaced the bulbs,I said bulbs,there is no sense in having to replace another bulb in who knows how long since only one had burned out but they were both the same age
Was this helpful?
Thank you for voting!
Not working as far as heating or cooking
151 of 361 people found this instruction helpful.
  • Theodore from Medical Lake, WA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Replaced High Voltage Diode. Very carfully due to the extream danger of a electrical shock.
Was this helpful?
Thank you for voting!
Oven would not power up
44 of 59 people found this instruction helpful.
  • Andras from Lexington, MA
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
There are 4 thermostats (aka TCO = Thermal Cut Out) in the GE JVM1440BH04
The schematic is under the cover in a black envelope to the top left of the unit if you face the door.

Check the fuse first. You can remove the front grate, then the numpad on the right. The fuse is right behind it. It's a 250V 20A Class F fuse. ... Read more />
There are four (4) TCOs or Thermal Cut Out thermostats in this puppy:

1) There is a thermostat behind the button panel to the left, facing down. If blown, it breaks the power coming into the unit and will cause a no power situation.

2) There is another TCO or thermostat near the top lamp, to the left, in a small cavity. That one also breaks power to the unit and will cause a no power situation. It's a 100 C / 0 C thermostat. This was the one that blew on me after I left the stove running (for heating in a black-out) under the microwave.


"Cavity TCO" or "Thermostat" part number 61 on the schematics, part number PS239319


3) There is yet another power-breaking TCO or thermostat in the cavity behind the fan that cools the microwave coils. You have to remove the sheet metal on the right of the microwave to access it. This one also breaks power and will cause a no power situation.

1), 2) and 3) should test out to be 0 Ohms with a resistance meter (Digital Multimeter) if working correctly.

4) There is a thermostat which normally does not let current through it. It is mounted in a vertical position to the back wall behind the front panel on the right. This one is used for the sensor reheat function apparently and will close when the temperature in the microwave reaches approx. 60 C.

4) should have infinite resistance with a resistance meter under normal circumstances.