- Home
- JMV8000ADB
- Instructions
JMV8000ADB Jenn-Air Microwave - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Lights bulbs burned out
4 of 4 people
found this instruction helpful.
-
Kat from Hudson, NC
- Really Easy
- 15 - 30 mins
-
Screw drivers
Really easy for a 75-year old female; just spent more time reading the online manual than actually installing the light bulbs to find out where to access the light bulbs.
Was this helpful?
Thank you for voting!
Microwave would not heat food. All other functionality was working as expected
6 of 10 people
found this instruction helpful.
-
James from Staten Island, NY
- Really Easy
- 15 - 30 mins
-
Screw drivers
I disconnected the power. Took off the front panel that was held together by two screws. Reviewed the schematic that was inside. Located the switches, saw which lead was burnt. Unscrewed the two screws that held the switch in place, cleaned the connector, and put the switch in and connectors back. Powered the device, tested for cooki
... Read more
ng/heating functionality. It worked, Closed the front panel
Read less
Was this helpful?
Thank you for voting!
No heat
4 of 4 people
found this instruction helpful.
-
John from SANTA CLARA, CA
- Really Easy
- 30 - 60 mins
-
Screw drivers
Removed case,
Discharged HV capacitor and removed cooling fan.
Unscrewed ground end of HV diode and unplugged from HV capacitor.
Installed new diode by reversing the order. In my case, the problem was the magnetron was bad, so I replaced it as well.
Discharged HV capacitor and removed cooling fan.
Unscrewed ground end of HV diode and unplugged from HV capacitor.
Installed new diode by reversing the order. In my case, the problem was the magnetron was bad, so I replaced it as well.
Was this helpful?
Thank you for voting!
Replace bulb under the microwave
5 of 8 people
found this instruction helpful.
-
Verne from HENDERSONVLLE, NC
- Very Easy
- Less than 15 mins
-
Screw drivers
Piece of cake. One screw to release the dropdown light diffuser. Just remember, the you're screwing the new bulb in from a reverse perspective. Also this site sends the correct part the first time.
Was this helpful?
Thank you for voting!
light bulb burned-out
13 of 34 people
found this instruction helpful.
-
Pablo from Burlingame, CA
- Really Easy
- Less than 15 mins
screwed in new bulb
Was this helpful?
Thank you for voting!
Range light bulbs were burned out
3 of 4 people
found this instruction helpful.
-
Barbara from MERIDIAN, ID
- Very Easy
- Less than 15 mins
-
Pliers, Screw drivers
We needed a phillips head screw driver to remove the single screw holding the light bulb cover in place.
Removing the old bulbs was a little work, because they had come loose from the sockets. We unplugged the microwave, so we could grip the sockets with a tool. I think my husband used a needle nose plier for this.
The new bul ... Read more bs screwed in easily, and then we refastened the light bulb cover with the phillips head screw driver.
Removing the old bulbs was a little work, because they had come loose from the sockets. We unplugged the microwave, so we could grip the sockets with a tool. I think my husband used a needle nose plier for this.
The new bul ... Read more bs screwed in easily, and then we refastened the light bulb cover with the phillips head screw driver.
Read less
Was this helpful?
Thank you for voting!
Exterior light bulb (PS2376034) broken off in socket. No access for pliers after glass cover removed.
3 of 4 people
found this instruction helpful.
-
Alvin from HILTON HEAD, SC
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Unplug appliance. Remove total of 7 phillips screws from sides and front of bottom panel . Panel front drops down, remove one socket screw and socket. Now have access for lineman' s pliers to unscrew bulb base. Reinstall socket, replace bulb and 7 panel screws. Restore power.
Was this helpful?
Thank you for voting!
light bulb burnt out .
3 of 4 people
found this instruction helpful.
-
DAN from CARPENTERSVLE, IL
- Really Easy
- 30 - 60 mins
Turn off power supply at breaker . Replace old bulb with new bulb .
Was this helpful?
Thank you for voting!
Microwave oven ran but stopped heating
2 of 2 people
found this instruction helpful.
-
Forrest from Eugene, OR
- Difficult
- 1- 2 hours
-
Screw drivers
I had to unmount the over-the-range microwave oven to be able to gain access to the interior of the oven. Complicating removal (and re-installation) was the fact that there is a "pot-filler" faucet installed directly underneath the oven. In retrospect, I should've removed the faucet before doing the repair, but "c'est la vie."
... Read more />After I got the microwave down, removing the case was also "interesting." I get bonus points for the fact that the previous owner must've had to replace the same diode before - and then re-assembled the microwave case incorrectly - thereby adding to the confusion (BTW, the service manual that I found online said nothing about how to remove the oven's case).
To remove the case, undo all the screws holding it on, and then rotate the case upwards from the back while also pulling the case backwards. There are crimped folds on the inside of the case that mate with the back edges of the front of the oven's chassis, and these folds have to be unclipped from the chassis in order to remove the case.
Replacing the diode itself was the easiest part of the job. The two connectors on the diode are of different types, making it impossible to install the diode with the wrong polarity.
BTW, the diode that had failed was not an OEM diode; I suspect it was a generic component that had been installed by a repairman sometime between 2004-2008 (when our home's original owners still owned the home). On the other hand, the new diode from PartSelect is an OEM part (it came packaged in a sealed Whirlpool bag).
The fact that the oven had stopped heating indicated that it was either the high-voltage diode or the magnetron that had failed. Since a replacement diode costs ~ 1/10th as much as a replacement magnetron, I figured it made sense to replace the cheaper part first. Fortunately, this fixed the problem.
One last thing: I tried testing both the old and new diodes for conductivity and polarity using my volt-ohm meter (VOM), but I was unable to get either diode to "turn on," even though my VOM is powered by a 9-v battery, and I used the 2-Mohm range setting. I guess the test voltage of my el-cheapo VOM isn't high enough to exceed the diode's threshold voltage, (even though I have successfully used this same VOM to test low-voltage diodes).
... Read more />After I got the microwave down, removing the case was also "interesting." I get bonus points for the fact that the previous owner must've had to replace the same diode before - and then re-assembled the microwave case incorrectly - thereby adding to the confusion (BTW, the service manual that I found online said nothing about how to remove the oven's case).
To remove the case, undo all the screws holding it on, and then rotate the case upwards from the back while also pulling the case backwards. There are crimped folds on the inside of the case that mate with the back edges of the front of the oven's chassis, and these folds have to be unclipped from the chassis in order to remove the case.
Replacing the diode itself was the easiest part of the job. The two connectors on the diode are of different types, making it impossible to install the diode with the wrong polarity.
BTW, the diode that had failed was not an OEM diode; I suspect it was a generic component that had been installed by a repairman sometime between 2004-2008 (when our home's original owners still owned the home). On the other hand, the new diode from PartSelect is an OEM part (it came packaged in a sealed Whirlpool bag).
The fact that the oven had stopped heating indicated that it was either the high-voltage diode or the magnetron that had failed. Since a replacement diode costs ~ 1/10th as much as a replacement magnetron, I figured it made sense to replace the cheaper part first. Fortunately, this fixed the problem.
One last thing: I tried testing both the old and new diodes for conductivity and polarity using my volt-ohm meter (VOM), but I was unable to get either diode to "turn on," even though my VOM is powered by a 9-v battery, and I used the 2-Mohm range setting. I guess the test voltage of my el-cheapo VOM isn't high enough to exceed the diode's threshold voltage, (even though I have successfully used this same VOM to test low-voltage diodes).
Read less
Was this helpful?
Thank you for voting!
microwave not heating
2 of 2 people
found this instruction helpful.
-
Mark from GREENSBURG, PA
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
removed a dozen screws-discarded large cap-replaced diode-replaced a dozen screws(took longer to replace them than remove for some unknown reason). Microwave now works(wife happy).
Was this helpful?
Thank you for voting!
Replacement of hood light bulbs
2 of 2 people
found this instruction helpful.
-
Jerry from Pine, CO
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
Unplug the microwave. Then remove the six screws that hold the lower panel which has the light bulb cover and a couple of vent filters. The light bulb sockets are on a fixture that is connected by a quick connect electrical connector. Disconnect that and the whole panel is free to access the bulbs. My bulbs were very fragile and tryin
... Read more
g to twist them out resulted in the glass twisitng loose with the base still in the sockets. I needed to use a needle nose pliers to remove the bases and then I replaced the bulbs and put every thing back together
Read less
Was this helpful?
Thank you for voting!
No power to any microwave functions
2 of 2 people
found this instruction helpful.
-
Richard from CALIFORNIA, KY
- Really Easy
- 15 - 30 mins
-
Screw drivers
Access is via RT. SIDE Panel as you face microwave. There are three screws on the bottom right edge to loosen. After that the side panel slips down and off. the fuse is located in the rear near where the power cord comes in. It is the white ceramic tube 1/4" in dia. and 1-1/2" long. Pull it out like any fuse and replace with new one.
... Read more
Reassemble and you are done!
Read less
Was this helpful?
Thank you for voting!
Burned out bulb
2 of 2 people
found this instruction helpful.
-
Theresa from OVERLAND PARK, KS
- Very Easy
- Less than 15 mins
-
Screw drivers
Husband replaced the bulb
Was this helpful?
Thank you for voting!
Burned out light in microwave
4 of 8 people
found this instruction helpful.
-
DANNY from SAINT JOHNS, FL
- Very Easy
- Less than 15 mins
-
Screw drivers
Spouse just screwed in the new bulb and reinstalled the light cover plate with the two screws. Took under a minute. Works great.
Was this helpful?
Thank you for voting!
Burned out light bulb which lit the surface of the range.
1 of 2 people
found this instruction helpful.
-
Michael J from LORAIN, OH
- Very Easy
- Less than 15 mins
-
Screw drivers
Unscrewed glass panel, removed old bulb, cleaned glass panel and installed new bulb. Screwed panel back into place.
Was this helpful?
Thank you for voting!