Noise coming from defrost timer
12 of 14 people found this instruction helpful.
  • Thomas from Pottstown, PA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Was this helpful?
Thank you for voting!
My refrigerator ran constantly and never got cold!
11 of 12 people found this instruction helpful.
  • Brandon from Fort Wayne, IN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
On a whim I looked into what it would take to fix my garage older 2nd fridge. I was thinking I needed a new seal, but when I checked the website there was a great troubleshooter. I would have never guessed that the defrost timer was what would cause it not to ever get cold. After a fairly simple repair the freezer is colder than ever a nd I actually had to turn it down. The only complication was the fridge was stuck in a defrost cycle so I had to reset the timer to get the refrigerator running. Thanks so much for a super helpful site for a do-it-yourselfer like me.
Was this helpful?
Thank you for voting!
Refrigerator door hinge screw missing
12 of 15 people found this instruction helpful.
  • William from Manchester, TN
  • Easy
  • Less than 15 mins
  • Socket set, Wrench set
Lost screw on bottom refrigerator door hinge which allowed the door to fall off. Purchased screw from Part Select for the Roper refrigerator. Drawings and parts list for this unit were available on their website. Easy repair.
Was this helpful?
Thank you for voting!
Motor slowing down and speeding up off and on
12 of 16 people found this instruction helpful.
  • James from Aubrey, TX
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Unplugged the machine removed the bottom plate and back plate and ice maker.Removed 2 wires to motor and ground wire.Removed 2 mounting nuts for motor,installed new motor and used old fan blade for new motor .Reinstalled in reverse order plugged in and tested fine.
Was this helpful?
Thank you for voting!
would not cycle
12 of 16 people found this instruction helpful.
  • Maxine from Birmingham, AL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
removed the defrost timer and replaced with new unit now i have a refrigerator again
Was this helpful?
Thank you for voting!
Freezer not coolling properly. Lower temp. 2 degrees upper temp. 60 degrees.
10 of 12 people found this instruction helpful.
  • John from Blairsville, GA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Take bottom racks and baskets out of freezer. Remove back sheet metal panel, 8 screws. Remove motor and bracket, 2 screws. Umplug wires on motor. Remove two more screws to take mounting bracket off motor. Install in reverse order. Simple job. Maybe 20 minutes. Besure to shut freezer off before startin work.
Was this helpful?
Thank you for voting!
socket melted with bulb in it.
12 of 18 people found this instruction helpful.
  • martin l. from JACKSONVILLE,, IL
  • Really Easy
  • Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people found this instruction helpful.
  • Lori from Chuluota, FL
  • Easy
  • Less than 15 mins
  • Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
light not working in fridge
7 of 8 people found this instruction helpful.
  • Michael from East Meadow, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Was this helpful?
Thank you for voting!
The old motor has built in wire harness. The new motor has connectors on it.
6 of 6 people found this instruction helpful.
  • Leo from EAGLE, WI
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Remove and clean out everything from the freezer and unplug the refrigerator. Take out the wire shelf in the freezer. (The fan motor is behind the back wall of the freezer, SO YOU CAN KEEP THE REFRIGERATOR CLOSED). Pop off the little cover on the center of the plastic shroud. Remove the little screw and carefully remove the plastic shroud . Remove the plastic cover for the optional ice maker on the upper left corner of the back wall. Take out the two screws in the upper corners on the back wall of the freezer and the last two screws holding the fan motor. The fan motor won't drop, remove the back wall and you will see two screws holding the motor mount. Remover those two screws, and pop the bracket out and separate.Take the two rubber motor mounts off the ends of the old motor and install them on the new motor. (Now you will have to cut the wires off the old motor), unplug the little wire harness, strip the ends and crimp on wire connectors to plug them onto your new motor. Its an AC motor so it shouldn't matter which hot goes on which of the two terminals. JUST MAKE SURE THE GROUND IS CORRECT! (After reinstalling the motor, plug in the refrigerator, turn it on before installing the shroud and make sure the fan is blowing outward. If all is correct, turn the refrigerator off, unplug and finish assembling the freezer. I found the new motor seems to run more efficiently than the old one.
Was this helpful?
Thank you for voting!
Refrigerator would not cool down. Evaporator fan inop.
6 of 7 people found this instruction helpful.
  • David from SHARPSBURG, GA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Unplug, then remove shelving and rear panel. Remove fan motor, swap wired and install new motor. Reinstall in reverse order. Plug back in and verify the fan is running. Easy and nothing special. Only thing I would caution is they use a foam runner to the refrigerator that may be iced up. Carefully clean the ice out before reinstalling eve rything. A follow up note. If the fan has not been running, Ice will build up in the drain tube. When you start up the refrigerator, you will see water dripping into the lower shelf. This is easy to fix. Unplug refrigerator and disassemble to where you can see the coils. There will be ice on the bottom covering the drain line hole. You will need to carefully chip away the ice, then use a hair dryer to melt the ice. Carefully use a pointed tool to push in the drain tube until the water drains. Go slow and be patient. Heat is your friend when doing this.
Was this helpful?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
7 of 10 people found this instruction helpful.
  • Antonio from San Antonio, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people found this instruction helpful.
  • Duncan from Metairie, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?
Thank you for voting!
Refrigerator had shut down
7 of 11 people found this instruction helpful.
  • Ronald from Martinsville, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Was this helpful?
Thank you for voting!
Raise side of fridge and slide 2x4 under side with broken wheel.
5 of 6 people found this instruction helpful.
  • Hans from OGDEN, UT
  • Really Easy
  • Less than 15 mins
  • Socket set
Remove back side cardboard access cover. About 6 dcrews need to be removed. Remove 9/16” bolt and lower compressor tray frame down to slide out wheel axel. Place wheel in slot and replace axel. Lift compressor tray and replace 9/16” bolt. Replace cardboard cover. Remove 2x4.