Fan was getting really noisy.
1 person
found this instruction helpful.
-
frankie from Port Richey, FL
- Really Easy
- 15 - 30 mins
-
Nutdriver
Looked at fan and seen it was rubbing metal cage. After looking and checking fan noticed bushings were worn letting fan hit cage. Repair was very easy. Used a 1/4 inch nut driver to remove bracket holding fan. Pulled fan blade off shaft by just pulling it forward. Removed fan and replaced grommets. Reassembled fan and fan blade. Took
... Read more
just 10 minutes.
Read less
Was this helpful?
Thank you for voting!
no water to icemaker
2 of 4 people
found this instruction helpful.
-
Bobby from Lewes, DE
- Really Easy
- 15 - 30 mins
-
Nutdriver, Wrench (Adjustable)
removed back cover--disconnect water supply-- removed screw holding vave and unplugged the
electric from the valve-- disconncect waterline to
the icemaker. reverse the to put on new part.
electric from the valve-- disconncect waterline to
the icemaker. reverse the to put on new part.
Was this helpful?
Thank you for voting!
Ice maker stopped working
1 person
found this instruction helpful.
-
Cary from ORLANDO, FL
- Really Easy
- 15 - 30 mins
-
Pliers
Remove the one screw holding the unit in place, unplug it, slide in the replacement, plug and screw it in.
Was this helpful?
Thank you for voting!
On/off switch stuck in the off position
1 person
found this instruction helpful.
-
Dan from HIGHLAND, MD
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
Removed icemaker from freezer,
Removed 3 screws from cover plate, and removed screw securing main gear, removed gear.
Pulled back cover plate to expose switches and mechanism.
Removed screw holding switch to remove switch, and installed new switch.
I should have taken a pic of the cover plate, the interior mechanism a ... Read more nd the wiring as I went along. It would have saved me 45 minutes in reassembly. Also, as luck would have it, I reversed the wiring on the switch. So off was on, and I had to remove it, switch wires and re-install.
But it works!
Removed 3 screws from cover plate, and removed screw securing main gear, removed gear.
Pulled back cover plate to expose switches and mechanism.
Removed screw holding switch to remove switch, and installed new switch.
I should have taken a pic of the cover plate, the interior mechanism a ... Read more nd the wiring as I went along. It would have saved me 45 minutes in reassembly. Also, as luck would have it, I reversed the wiring on the switch. So off was on, and I had to remove it, switch wires and re-install.
But it works!
Read less
Was this helpful?
Thank you for voting!
Freezer was cold but fridge was warm. Coils in the back of the freezer were getting frosted. Defrost Sensor was broken
1 person
found this instruction helpful.
-
Kevin from Charlotte, NC
- Easy
- 30 - 60 mins
-
Socket set
-Empty the freezer
-Take the cover in the back of the freezer off
-Melt the ice off the coils (heat gun, hot water, etc.)
-Cut the wires off the old sensor and connect the new sensor using a soldering iron or some other method.
-Cover the spliced wire with heat shrink, electrical tape or some other method.
-Reasse ... Read more mble the cover
Done!
-Take the cover in the back of the freezer off
-Melt the ice off the coils (heat gun, hot water, etc.)
-Cut the wires off the old sensor and connect the new sensor using a soldering iron or some other method.
-Cover the spliced wire with heat shrink, electrical tape or some other method.
-Reasse ... Read more mble the cover
Done!
Read less
Was this helpful?
Thank you for voting!
Had a 'ticking' sound
1 person
found this instruction helpful.
-
John from PARKVILLE, MO
- Easy
- 30 - 60 mins
-
Socket set
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side o
... Read more
f the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
Read less
Was this helpful?
Thank you for voting!
Water valve failed. Constant drip in ice maker.
1 person
found this instruction helpful.
-
Steven from RUSHVILLE, IL
- Easy
- 30 - 60 mins
-
Screw drivers, Socket set, Wrench set
Removed old valve easily. New WR57XI0033 valve is designed to mount on lower left, but on mine it has to mount on lower right. Had to drill two 1/32 holes in lower rail to mount the new valve.
Was this helpful?
Thank you for voting!
Evaporator coil freeze up
1 person
found this instruction helpful.
-
Michael from BRADENTON, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver
Up plug from wall removed rear access cover in freezer let thaw out and replace two wire sensor had previously checked out knowing the defrost strip was good and the defrost thermostat was visually deformed and tested open at freezing and 40 degrees
Was this helpful?
Thank you for voting!
Noisy
1 person
found this instruction helpful.
-
Brad from SPRING MILLS, PA
- Very Difficult
- More than 2 hours
I didn’t do the repair because I ordered two grommets. When they arrived, one of the packages was empty! Instead of just sending me another one, they refunded the part so I still need one. By the way, I was not refunded half the shipping either which was more than the part itself.
Was this helpful?
Thank you for voting!
Leaking And Making Stalactites
2 of 4 people
found this instruction helpful.
-
Richard from Zephyrhills, FL
- Easy
- More than 2 hours
-
Nutdriver, Screw drivers
Had to defrost the freezer to melt off all the ice before servicing. Once that was done the icemaker replacement only took about 15-30 minutes to complete. The new icemaker came with many accessories and adaptors that were not needed and the instructions were based on replacing an older model and not really clear for my model. They men
... Read more
tioned not being able to use the new stripper but it was exactly the same as the old one so I left the new one in place. All in all it was easy and did the job.
Read less
Was this helpful?
Thank you for voting!
The control board generated clicking noise. Temperature display wrong values.
1 of 2 people
found this instruction helpful.
-
QUOC-LOC from LYNN HAVEN, FL
- Really Easy
- 30 - 60 mins
-
Screw drivers
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
P ... Read more lugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
P ... Read more lugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
Read less
Was this helpful?
Thank you for voting!
Change bulb
3 of 8 people
found this instruction helpful.
-
Louis from LEAGUE CITY, TX
- Really Easy
- 30 - 60 mins
-
Nutdriver
Easy
Was this helpful?
Thank you for voting!
Ice Maker was not working
2 of 5 people
found this instruction helpful.
-
FRANK M from EASTON, PA
- Really Easy
- 1- 2 hours
-
Nutdriver, Screw drivers, Wrench set
1st - checked water supply - old valve in water line was closed with sediment.
2nd - replaced water line valve and reconnected copper tubing about 1 hour
3rd. removed single outlet valve and installed the new part - about 15 minutes
Everything went well and was very easy.
Unfortunately, the ice maker still does ... Read more not work.
Still trying to understand what is wrong.
2nd - replaced water line valve and reconnected copper tubing about 1 hour
3rd. removed single outlet valve and installed the new part - about 15 minutes
Everything went well and was very easy.
Unfortunately, the ice maker still does ... Read more not work.
Still trying to understand what is wrong.
Read less
Was this helpful?
Thank you for voting!
A few small ice cubes in an empty try on return from vacation
1 of 2 people
found this instruction helpful.
-
Robert from Loudon, TN
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Screw drivers
Look at various pertenant DYI articles and videos on the internet. Replaced water filter with bypass plug. Checked water flow to icemaker water solenoid. Ran icemaker diagnostic test which failed. Ordered replacement. On receipt of replacement, began replacement work. To wit: Pulled fiidge from wall and unplugged. (Not necessary to shut
... Read more
water off.) Removed small freezer basket. Unloaded main freezer basket, removed it then removed the freezer door. (A screw on each side bolts the door rail of the chassis slide to the freezer chassis slide.) Loosened screws on rear, top of partition between icemaker and small freezer basket. Pushed up on partition front and popped out U-bar supporting partition bottom being carefull not to bend it. Removed same. Removed screws from partition and set aside. Removed grilled "thingy" between rear of icemaker and partition. Now have access to icemaker screws. Loosened the screws, pushed up and out and carefully let it hang by it's connector. Fiddled with the connector locking tabs and finally got it loose. Compared old and new icemaker. Have to keep the old water funnel. The new wiring harness was stiff and the connector had a different orientation. Twisted both the wiring harness and connector to align connector while the icemaker hung by it's cable being careful not to let the icemaer slip and fall to the bottom. After much fiddling, got the connector inserted and locked. Set icemaker over the two screws, pulled it down and tightend the screws. Put the old funnel into the new unit being very careful to get it right the first time. Put grilled "thingy and the partition and U-bar back in, put door back on, put the ice cube bin back, freezer drawers bac and reloaded the frozen food, plugged fridge in. Done! Time to replace icemaker was about 20 minutes and another 2 hours to do the rest ofthe work. Still required only a nutdriver and phillips.
Read less
Was this helpful?
Thank you for voting!
Ice maker wouldn't shut off
1 of 2 people
found this instruction helpful.
-
Grant from Black Canyon City, AZ
- A Bit Difficult
- 15 - 30 mins
-
Screw drivers
unplug refrigerator. Remove Ice bin then remove the cover off the ice maker,(slides off from bottom then lift off top) no reason to remove ice maker completely. Remove center gear screw and remove main gear from Ejector blade. remove (3) screws holding the front plate. The motor and switches are attached to this plate from behind, do not
... Read more
remove the nut from the from the stud that adjusts the travel for the motor. The Motor and switches will come upt with the plate and the shut off arm will come out of a hole in the top right. Its ok just be careful when you put it back to get it in the hole. remove the old cam and replace it wint the new one and reassemble. Its a bit tricky to get all of the microswitches over the new cam just carefully wiggle the plate and cam and don't push too hard. once everything is lined up it should go back together and you can replace the screws and main gear :)
Read less
Was this helpful?
Thank you for voting!