water valve didn't shut off completly
20 of 24 people found this instruction helpful.
  • Raymond from Concord Twp., OH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set, Wrench (Adjustable)
The valve is not a direct replacement,seems they
are not available,had to bend mtg. brkt. so valve
would mount in same position and cut off screw
type pressure fitting so could slide discharge
tube into new type connection, no instructions
come with replacement valve,asked several
places for info wanted to be sure before cutting
off end of discharge tube. Now valve shuts off
but water still in base of refrigerator must be a
leak in inlet tube behind freezer compartment.
Was this helpful?
Thank you for voting!
Replace ice maker
21 of 28 people found this instruction helpful.
  • Gary from Glendale, AZ
  • Easy
  • 15 - 30 mins
  • Screw drivers
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice b in had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Was this helpful?
Thank you for voting!
Water leak caused by earlier tube replacement destroying retaining washer in valve
18 of 20 people found this instruction helpful.
  • George from Islamorada, MD
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
This was a simple parts replacement. I had replaced the cracked plastic tube a few weeks earlier and destroyed the retaining star washer inside the solenoid valve while removing the old one. It worked for a while and then started to leak when the tube had partially worked its way out. The star washer is not a replaceable part so this repa ir was simply replacing the valve with a new one. It is very straight forward - disconnect the electric plug, remove the old valve, insert the tube in the new valve (it goes through the plastic bushing in the valve - do not remove the bushing - it can easily be mistaken for a shipping plug) and reattach the supply line being careful to avoid kinking it. Reattach the valve, the electric plug and support clips for both the supply line and the plactic line to the ice maker.
Was this helpful?
Thank you for voting!
Ice maker would not make ice..
19 of 23 people found this instruction helpful.
  • James from Mebane, NC
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmm eter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
Was this helpful?
Thank you for voting!
The refrigirator light would not come on.
26 of 44 people found this instruction helpful.
  • Jania from Novato, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Was this helpful?
Thank you for voting!
Stripper on the icemaker broke into pieces.
18 of 23 people found this instruction helpful.
  • Tracy from Yuba City, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this helpful?
Thank you for voting!
Ice maker did not work
15 of 18 people found this instruction helpful.
  • Kenneth from Bellevue, WA
  • Easy
  • 15 - 30 mins
  • Screw drivers, Wrench set
I removed one screw to loosen the cardboard panel that covered the old valve and one screw to remove the valve assembly. I disconnected the two wiring connections and unscrewed the two water line connections. Replacement was really easy since the bracket was the same as the old valve. The down stream water connection was different for the new (push in) than the old (threaded) but I cut the old threaded connector off and figured out that the new push in connection was solid (directions would have really helped here) Reconnected the inlet tubing and electrical wires and replace the panel and it was done.
Was this helpful?
Thank you for voting!
ice maker not making ice
16 of 22 people found this instruction helpful.
  • Cristina from Los Angeles, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Was this helpful?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
19 of 33 people found this instruction helpful.
  • Terry from Simi Valley, CA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring s o it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this helpful?
Thank you for voting!
icemaker developed a leak and froze over
18 of 30 people found this instruction helpful.
  • debbie from chino hills, CA
  • Easy
  • 15 - 30 mins
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Was this helpful?
Thank you for voting!
Ice maker ot making ice
18 of 31 people found this instruction helpful.
  • Barry from Phoenix, AZ
  • Easy
  • 15 - 30 mins
  • Nutdriver
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Was this helpful?
Thank you for voting!
Existing light switch was hard to remove.
14 of 19 people found this instruction helpful.
  • Stephen from Jupiter, FL
  • A Bit Difficult
  • Less than 15 mins
  • Screw drivers
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Was this helpful?
Thank you for voting!
Interior light needed replaced
22 of 46 people found this instruction helpful.
  • Leo from TWIN FALLS, ID
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Was this helpful?
Thank you for voting!
Refrigerator section not cold, freezer section cold
10 of 10 people found this instruction helpful.
  • David from Shalimar, FL
  • A Bit Difficult
  • More than 2 hours
  • Pliers, Screw drivers, Socket set, Wrench set
Based on the relatively young age of refrigerator, I suspected the defroster electrical circuit. The evaporator core in the freezer was frozen solid, which confirms that the defrost heater circuit is not working. Thawed out (with a hot air gun) and disassembled the freezer section to access the evaporator core and defrost heater. If yo u have an ice maker, you will have to remove it to disassemble the freezer section. Confirmed with a voltmeter and ammeter that the defrost heater was not getting voltage. When the defrost heater is working, it will glow with an orange color. Also confirmed with a voltmeter that the defrost timer, located in the refrigerator section was working correctly. You can use a common blade screwdriver to rotate the timer through the cold and defrost cycles. Finally, I determined with a voltmeter and ammeter that the defrost thermostat, located on the evaporator core was not switching the defrost heater voltage. Ordered a new thermostat ($12) from this website and installed it. Refrigerator is as good as new. Be careful, there are many electrical hazards during the troubleshooting phase. Safety first.
Was this helpful?
Thank you for voting!
Refridgerator Freezer stoped making ice
17 of 31 people found this instruction helpful.
  • Marion from Palm Coast, FL
  • Easy
  • 30 - 60 mins
  • Screw drivers
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Si licone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
Was this helpful?