- Home
- HST22IFPDCC
- Instructions
HST22IFPDCC Hotpoint Refrigerator - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Dairy Door Cover had cracked
21 of 29 people
found this instruction helpful.
-
Stephanie from Tampa, FL
- Really Easy
- Less than 15 mins
Repair took about 5 seconds. No directions necessary. Super easy.
Was this helpful?
Thank you for voting!
refrigerator wasn't cooling
19 of 23 people
found this instruction helpful.
-
James from LaGrange, KY
- Really Easy
- 15 - 30 mins
-
Socket set
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires, it was really simple. I conected the new element & defrost themostat (instuctions were included with the parts). I replaced the cover pluged the fridge in everything was woking fine. I placed a themom
... Read more
eter in the fridge & have been watching it for 2+ weeks now it is working fine. To anyone who is looking to do this repair, on thier own, I reccomend it. It was very simple & required little to no skill. No reasopn to throw away money to call a repair man.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
no problem
18 of 21 people
found this instruction helpful.
-
William from West Union, SC
- Really Easy
- Less than 15 mins
I had lost the provided bypass filter plug. I decided to replace it with your part.
Was this helpful?
Thank you for voting!
Cracked Housing Mount - water leak
19 of 25 people
found this instruction helpful.
-
Richard from Chandler, AZ
- Really Easy
- 15 - 30 mins
-
Screw drivers, Socket set
Turned off the water. Removed the maintenance cover plate on the back of the refrigerator and disconnected the tubing. Removed the tubing cover plate on back of refrigerator. Removed two screws from filter hosing mount on the inside of the refrigerator and pulled the old tubing out. Simply inserted the new tubing and mounted the housing a
... Read more
nd reconnected the tubing using plumber’s pipe compound. Then re-installed the cover plates on the back of the refrigerator, installed the filter and turned on the water. It was a very easy install.
Read less
Was this helpful?
Thank you for voting!
Stripper on the icemaker broke into pieces.
18 of 23 people
found this instruction helpful.
-
Tracy from Yuba City, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this helpful?
Thank you for voting!
A piece of the crusher cover broke off into the ice bin
18 of 23 people
found this instruction helpful.
-
David from Woodland Hills, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
I removed the ice bin, removed the metal rod off the bottom, unscrewed all screws holding things together and then carefully pried the crusher assembly out of the ice bin. I made the mistake of doing it when the bin was still frozen and ended up cracking it where the "clips" from the crusher are inserted. It was much easier after the bi
... Read more
n warmed up.
Replaced and put everything back together.
Replaced and put everything back together.
Read less
Was this helpful?
Thank you for voting!
low water flow from in door water dispenser
17 of 20 people
found this instruction helpful.
-
kevin from summerville, SC
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
after changing the water filter and having no improvement. I went to the next part of the system. Turned off the water supply. I removed the bottom cover in the back of the refrigerator. unscrewed the nuts on the water supply hose from the main supply and the one going back into the fridge. moved to the inside of fridge and unscrewed two
... Read more
screws holding the filter mount and pulled the tubing through. Reversed my steps and the water flow was great . Thanks
Read less
Was this helpful?
Thank you for voting!
The Ice Bucket Was Cracket And The Auger Also Broken.
18 of 23 people
found this instruction helpful.
-
Sharon from Glendale, AZ
- Difficult
- 30 - 60 mins
-
Screw drivers
I was able to order the correct parts . Needed my son in law (who in an engineer) to put it together. It was sort of a challenge forhim too. W the persons that I spoke to were very helpful and very nice and the parts came quickly. Thank heavens for the internet. The part that was broken was inside the freezer part of my frig.
Other Parts Used:
Was this helpful?
Thank you for voting!
Icemaker supply hose leaking at freezer entrance
18 of 24 people
found this instruction helpful.
-
Michael from Meridian, MS
- Easy
- 15 - 30 mins
-
Nutdriver, Wrench set
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are
... Read more
excellent!
Read less
Was this helpful?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
15 of 17 people
found this instruction helpful.
-
D from ZELLWOOD, FL
- Easy
- 15 - 30 mins
-
Screw drivers
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Was this helpful?
Thank you for voting!
The rubber ice deflector fell off becasue the funnel failed
18 of 26 people
found this instruction helpful.
-
Martin from Mount Pleasant, SC
- Easy
- 15 - 30 mins
-
Screw drivers
After removing the front cover to the control panel, I removed the 3 connectors. Then I removed the 4 screws and pulled out the assembly with the funnel.
The I had to lift the plastic tabs on the left and right to release the funnel. Reinstalling the funnel was a little tricker, trying to get the two plastic tabs, the spring an ... Read more d the tab that works the switch all in place at the same time. Then I installed the rubber deflector onto the funnel (the original problem.)
Finally reinsert the assembly, install the 4 screws, attach the 3 connectors, slide the panel back into place starting at the top and then the bottom
The I had to lift the plastic tabs on the left and right to release the funnel. Reinstalling the funnel was a little tricker, trying to get the two plastic tabs, the spring an ... Read more d the tab that works the switch all in place at the same time. Then I installed the rubber deflector onto the funnel (the original problem.)
Finally reinsert the assembly, install the 4 screws, attach the 3 connectors, slide the panel back into place starting at the top and then the bottom
Read less
Was this helpful?
Thank you for voting!
loss of refrigeration
15 of 17 people
found this instruction helpful.
-
Heather from Pennington, NJ
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
After mopping up the floor - the whole freezer that was iced up melted - that's how I found out about the problem...
Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering ... Read more the top screw.
With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.
With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.
With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.
Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...
NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering ... Read more the top screw.
With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.
With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.
With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.
Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...
NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
Read less
Was this helpful?
Thank you for voting!
Ice auger was broke and ice was freezing in the recess door
21 of 36 people
found this instruction helpful.
-
danny from west potsmouth, OH
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
all parts worked and were easy to install. probably saved me from having to buy a new fridge. ice maker is working fine and recess door flap is closing correctly. very satisfied.
Other Parts Used:
Was this helpful?
Thank you for voting!
Iced up Freezer compartment in SxS
15 of 18 people
found this instruction helpful.
-
Jamison from Heltonville, IN
- Really Easy
- Less than 15 mins
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice m
... Read more
aker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Read less
Was this helpful?
Thank you for voting!
My 13 yr grandson assisted me on this
15 of 18 people
found this instruction helpful.
-
Sherry from Auburn Hills, MI
- Really Easy
- Less than 15 mins
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Was this helpful?
Thank you for voting!