EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

GRS22WRAD0 Gibson Refrigerator - Instructions

All Instructions for the GRS22WRAD0
1 - 15 of 412

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Fridge got warm and freezer coils were frosted
340 of 407 people found this instruction helpful.
  • Stephen from Warrington, PA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Fridge is a side by side. The freezer is pretty narrow for a guy with wide shoulders.

Pulled plug.

Had to remove bottom drawers then used nut driver to remove screws closest to back wall in drawer runners. Once the back screws were removed the runners could be swung up or down out of way so back cover could be re moved.

Once back cover was removed thermostat was located attached to top pipe going into coil using a spring clamp.

Cut the wires just outside the crimp connectors going into thermostat. Released the spring clamp buy squeezing botton together.

Removed old badly corroded thermostat.

I wish I had attached the crimp connectors to the new thermostat wires before mounting it. Reaching way in the back, while turning shoulders verticly and trying to get the wire connectors set from both sides was awkward and uncomfortable...The biggest PIA of the whole task.

Once connected I let the fridge (thermostat) cool for 10 min. Turned the dial defrost timer to get it into defrost mode. Stupidly touched the heating element to see if it was getting warm...it was very hot.

Coils steamed...every looked like it was working. Unplugged, put back cover back on and retattached drawer mounts.

Plugged back in and everying is working great!
Was this helpful?
Thank you for voting!
Broken ice maker
255 of 343 people found this instruction helpful.
  • Juan from Miami, FL
  • Really Easy
  • 15 - 30 mins
  • Socket set
Unplugged faulty ice maker, removed two screws holding it to the refrigerator and took it out. Reversed the operation with the new ice maker and after a few minutes presto, we have ice.
Was this helpful?
Thank you for voting!
Ice Maker Stopped Working
164 of 183 people found this instruction helpful.
  • JACK from MESA, AZ
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
It was pretty straight forward. Remove the two screws that hold the unit to the wall of the freezer. In my case, I had to use a different ice maker than what came with the frig. In order to install the replacement unit they sent a wire adaptor so it would attach to the existing wiring. That too was all fine and dandy. The only p roblem was that the end of the wire adaptor did not fit through the existing hole in the rear of the frig. I used a utility knife to cut through the thin metal lining. That worked just fine. However, I could not cut through the insulation because I could not reach it through the small hole. The excess wire was supposed to be pulled through the hole and out through the back of the unit. So now the excess is between the wall of the freezer and the insulation. The unit is working wonderfully. In fact, it is making more ice than I can use. I am very pleased with the replacement unit. This is the 3rd ice maker that has been in this frig. All the others had a design flaw that had a leak in the rear of the unit. This caused all the ice to form into a big block. The replacement unit has not had this problem so far. Thank you for allowing me to explain my situation so that maybe others may benifit from my experience. Thank you. Jack
Was this helpful?
Thank you for voting!
Clicking sound then within a minute clicking again, not cooling.
81 of 97 people found this instruction helpful.
  • Melvin from Semmes, AL
  • Easy
  • Less than 15 mins
UNPLUG REFRIGERATOR. Carefully remove relay from the side of the compressor. You shouldn't need a tool to do this, if it is hard you can gently pry the edge with a flat head screw driver just to loosen. Unplug white and red wires from relay, noting that the white wire goes in the hole with a #2 stamped beside it. Shake old relay, if it r attles like a baby rattler then it's most likely the problem. Replace wires into the new relay and plug back into the compressor.
Was this helpful?
Thank you for voting!
Water resevoir tank was leaking
73 of 98 people found this instruction helpful.
  • Suzanne from Collinsville, IL
  • Difficult
  • 1- 2 hours
  • Pliers, Screw drivers, Wrench set
Manufacuturer does not make the tanks any more. Had to by a replacement kit which is basically a 40 ft. plastic tube worth about $10 but they charge you upwards of $55 for it. What a RIP OFF!!! Comes with a self-tapping screw that does not self tap. After 30+ minutes of both of us trying to get the screw to self-tap, we got the drill and started the hole that way. Got coiled hose in place and it is too wide. It is supposed to fit behind the fruits & vegetables drawer. But now drawer will not close all the way. Hose was bound too bulkily. this website was the cheapest place I could find the part. Paid about $63 including S&H. All the places I went to locally wanted to charge me any where from $105 to $127 -- not including taxes.
Was this helpful?
Thank you for voting!
Ice maker stopped producing ice
61 of 76 people found this instruction helpful.
  • Jeremy from Peoria, AZ
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver, Screw drivers
First I removed ice maker and tested the micro switches and motor individually. Then checked the resistance of the heater element, and the thermostat. All components tested okay and worked individually. However when installed in the freezer the motor would not turn. and if you manually turned the gear in front, which should cycle everythi ng,nothing would happen. Finally, I found one part that I had not checked, the thermal cut-off, and upon removing it, one wire fell off the small square piece. This wire was corroded. I replaced the unit in about 10 minuites and ice maker is working perfectly again.
Was this helpful?
Thank you for voting!
Side-by-side .. freezer working, fridge not cooling
48 of 52 people found this instruction helpful.
  • Tad from Lancaster, OH
  • Easy
  • 15 - 30 mins
  • Screw drivers
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc . After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself
Was this helpful?
Thank you for voting!
Wouldn't hold temp.
49 of 58 people found this instruction helpful.
  • Laurence from Overland Park, KS
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
I'm too young to die so I unpluged the refriderator first. The cold control is mounted in a plastic housing at the top of the freezer compartment that is held in place by two screws on the back side. I removed them with a nutdriver. Pull off the knob and use a screwdriver to release the control from it's bracket and pull off the 3 wire s noteing where they go. Slide the sensing element out and remove the plastic sleeve. Stragihten the sensing element on the new control and slide on the plastic sleve. Slide the sensing element in place, push the wires onto the terminals and snap the control into the bracket. Re-install the two screws and the control knob. Plug it in and you're done. It took longer to write this than to replace the control.
Was this helpful?
Thank you for voting!
Ice maker died!
45 of 49 people found this instruction helpful.
  • John from Las Vegas, NV
  • Really Easy
  • Less than 15 mins
  • Socket set
The repair for this was very simple, although it was a tight squeeze. The model I replaced the ice maker on was a side by side. First I removed the ice bucket so I could have more room to work with. Then I unscrewed 2 screws on the left side wall holding the ice maker in place. These screws had a 1/4" nut top on them so I used my socke t driver for this. Then a quick disconnect of the wiring harness. Very Simple. I did the reverse to install the new unit. Total time was around 5 minutes or so. I now have ice again.
Was this helpful?
Thank you for voting!
Storage drawer glides broken
47 of 56 people found this instruction helpful.
  • J Matthew from Great Bend, KS
  • Really Easy
  • Less than 15 mins
I slid the drawer fronts off by pulling out slightly on the bottoms and pulling up. The drawer fronts come right off. Then slide them onto the new drawers that matched perfectly. It took longer to empty the broken drawers than it did to replace them.
Was this helpful?
Thank you for voting!
Ice Maker stopped working
39 of 47 people found this instruction helpful.
  • Dennis from DEER LODGE, MT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Reviewed the video on your website and followed the directions to the letter. Great video
Was this helpful?
Thank you for voting!
The old ice maker had stopped working properly. The cycle was inconsistent, and inlet water would run over existing cubes in the tray, before they were dumped into the dispenser box.
29 of 31 people found this instruction helpful.
  • Daniel from Baldwin City, KS
  • Really Easy
  • Less than 15 mins
  • Nutdriver
This was really simple, much like changing a light bulb. Two bolts loosened beneath the old unit to allow it to be lifted off and free. The power supply plug was easily disconnected. The new unit was then placed onto the loosened bolts, power supply reconnected and secured with the supplied wire tie. A small angled bracket was removed from the old and reattached to the new as a support toward the from of the unit. The cycle adjuster was backed off a 1/2 turn as per the instructions....and the next morning....new automatic ice. Life is good!
Was this helpful?
Thank you for voting!
no cooling in fridge or freezer due to bad defrost timer
29 of 37 people found this instruction helpful.
  • Todd from pottstown, PA
  • Easy
  • Less than 15 mins
  • Screw drivers
i removed the 4 screws holding cover. removed two screws holding timer. unplugged timer. plugged in new one. reassembled.
Was this helpful?
Thank you for voting!
Old icemaker would not cycle to make ice.
24 of 26 people found this instruction helpful.
  • David from Cedar City, UT
  • Easy
  • 15 - 30 mins
  • Nutdriver
I had already removed the ice maker by loosening the two screws with a 1/4" nut driver, in order to compare the design and style to the intended replacement for size and critical measurements. The replacement was almost identical. The wiring harness was 2-3" longer than the original, but after snaping the wire plugs together I simply cur ved the wire up and to the left to be out of the way. The hanging brackets are slotted and it was easiest to slip the back hanger over the head of the screw and let it slip down, then the front hanger was already to line up even though you can't see the screw with the ice maker in the way. I had to transfer an L-shaped metal bracket to the bottom side, matching the old assembly, and adjusting it to hold the bottom side away from the freezer compartment a little so it would hang level and secure. You have to snug the two screws with a screw driver or 1/4" nut driver by feel, since you can't see them with the icemaker in place. It took about 10 minutes to take out the old and another 10 to put in the new. We now have a full bin of ice, and the old plastic trays have been retired. I should have done this a year ago.
Was this helpful?
Thank you for voting!
Ice maker quit working
27 of 35 people found this instruction helpful.
  • Robert from SIOUX FALLS, SD
  • Really Easy
  • 30 - 60 mins
  • Nutdriver
Loosen two screws, unclip electrical connection, remove ice maker, remove l shaped leveling piece of metal from old one, put on new one. Install in reverse order. Hint.. when loosening two screws, use a mirror
Was this helpful?
Thank you for voting!
All Instructions for the GRS22WRAD0
1 - 15 of 412