The freezer was not keeping food frozen
6 of 7 people
found this instruction helpful.
-
Jeffry from VERONA, WI
- Easy
- 1- 2 hours
-
Screw drivers
I replaced the timer and the defrost thermostat. The defrost thermostat replacement was almost exactly like the training video here. The old part attached slightly differently. The most time consuming part was thawing out the heat exchanger, which was completely covered with ice, inside and out.
Compared to the training video, ... Read more the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Compared to the training video, ... Read more the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Freezer was freezing solid
6 of 7 people
found this instruction helpful.
-
Matt from Cincinnati, OH
- Easy
- Less than 15 mins
-
Pliers
I first replaced the defrost timer about a week prior and it did not correct the problem. I then ordered the thermostat from partselect and within 15 minutes had the part installed. My refridgerator has been running correctly for a couple weeks.
Was this helpful?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
5 of 5 people
found this instruction helpful.
-
Bruce from MARTINEZ, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to ... Read more uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to ... Read more uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Read less
Was this helpful?
Thank you for voting!
Freezer was running too warm
6 of 8 people
found this instruction helpful.
-
Jeanne from SAN ANTONIO, TX
- Very Easy
- Less than 15 mins
-
Screw drivers
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Was this helpful?
Thank you for voting!
Refigerator Not Staying Cold
5 of 5 people
found this instruction helpful.
-
Marsha from BEVERLY, MA
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers, Wrench set
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely
... Read more
does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
Read less
Was this helpful?
Thank you for voting!
Getting frost build up on the inside at the top of the door .
4 of 4 people
found this instruction helpful.
-
Gene from VICTORVILLE, CA
- Really Easy
- 30 - 60 mins
removed door and took all the screws out of the inside door rack. removed old door seal . replaced door seal and made sure that the seal fit around and door rack fit into the groove then replaced all screws and tightened choosing random sections to tighten .replaced the door plugged back in wires that I removed and replaced door hinge scr
... Read more
ews . Shut door and checked sealing 2 hours later .Complete seal .
Read less
Was this helpful?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
5 of 7 people
found this instruction helpful.
-
gary from ARANSAS PASS, TX
- Easy
- 30 - 60 mins
-
Nutdriver
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though ... Read more it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though ... Read more it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Read less
Was this helpful?
Thank you for voting!
Old gasket was broken
4 of 4 people
found this instruction helpful.
-
Henry from BYRON, GA
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
Removed old gasket, then installed new gasket. Make sure to allow new gasket to set out for a few days prior to installing to get all wrinkles out, use a heat gun after installing to make gasket shape to freezer door.
Was this helpful?
Thank you for voting!
Compressor not running, food defrosting.
8 of 17 people
found this instruction helpful.
-
Thomas from Centerville, MA
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
Cycled the defrost timer but compressor still would not kick in. Cycled the cold control, and after a while it started only to hang up again after a few hours. Replaced the cold control, now running normal.
Was this helpful?
Thank you for voting!
Compressor keep running would not cool.frozen coil
4 of 5 people
found this instruction helpful.
-
Mark from SEYMOUR, TN
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
As per instructions.removed inside shelves.removed back cover over coil let thaw.removed old thermostat &clips as per instructions.replaced with new.
Was this helpful?
Thank you for voting!
freezer would frost up and not get cold enough to keep frozen.
3 of 3 people
found this instruction helpful.
-
Richard from SLIDELL, LA
- Very Easy
- 15 - 30 mins
-
Screw drivers
Removed shelves ,removed panel on interior back wall with Philips screwdriver ,unplugged wire terminals slid thermostat off coil ,then reversed process to complete installation.
Was this helpful?
Thank you for voting!
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
3 of 3 people
found this instruction helpful.
-
Tunis from NOLANVILLE, TX
- Easy
- 15 - 30 mins
-
Screw drivers
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
Was this helpful?
Thank you for voting!
Defrost Timer
4 of 6 people
found this instruction helpful.
-
DAVE from LOS RANCHOS, NM
- Very Easy
- Less than 15 mins
-
Screw drivers
The old defrost timer started making a screeching noise (probably bearings going out). The replacement part was a cinch to install. When I initially spoke to a PartsSelect person, they said the part number I gave them was not consistent with my old '94 Tappan Freezer. They were able to still find the proper replacement part number. Th
... Read more
e video that was on-line helpful also.
Read less
Was this helpful?
Thank you for voting!
Freezer not cooling due to icing up of coil.
2 of 2 people
found this instruction helpful.
-
Thomas from GRANBURY, TX
- Really Easy
- 15 - 30 mins
-
Screw drivers
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In
... Read more
order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Read less
Was this helpful?
Thank you for voting!
No problems at all !!!
2 of 2 people
found this instruction helpful.
-
Jacques from Henrico, VA
- Very Easy
- 1- 2 hours
-
Screw drivers
On 08/13 / 2025 starting in the AM --- My Wife Marie Defrosted -- Cleaned and dried the Kenmore up right freezer she has had for more than 33 years --- She noticed there was screws behind the inside door gasket and informed yours truly --- 1st Jacques loosened all the screws then removed the old gasket -- took it cleaned it and boxed it
... Read more
in the box the new gasket came in --- Took new freezer door gasket and installed it neatly around the door by tucking back part of door gasket between door panel and door --- once all was in place started tightening all screws starting at bottom holding bottom gasket material tight with other hand --- then working counter clock wise till done !!! there you go it was very easy and turned out great !!! Now everything is like new !!! Jacques And Marie / from Virginia
Read less
Was this helpful?
Thank you for voting!