Fridge got warm and freezer coils were frosted
Fridge is a side by side. The freezer is pretty narrow for a guy with wide shoulders.

Pulled plug.

Had to remove bottom drawers then used nut driver to remove screws closest to back wall in drawer runners. Once the back screws were removed the runners could be swung up or down out of way so back cover could be removed.

Once back cover was removed thermostat was located attached to top pipe going into coil using a spring clamp.

Cut the wires just outside the crimp connectors going into thermostat. Released the spring clamp buy squeezing botton together.

Removed old badly corroded thermostat.

I wish I had attached the crimp connectors to the new thermostat wires before mounting it. Reaching way in the back, while turning shoulders verticly and trying to get the wire connectors set from both sides was awkward and uncomfortable...The biggest PIA of the whole task.

Once connected I let the fridge (thermostat) cool for 10 min. Turned the dial defrost timer to get it into defrost mode. Stupidly touched the heating element to see if it was getting warm...it was very hot.

Coils steamed...every looked like it was working. Unplugged, put back cover back on and retattached drawer mounts.

Plugged back in and everying is working great!
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Stephen from Warrington, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
336 of 400 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken ice maker
Unplugged faulty ice maker, removed two screws holding it to the refrigerator and took it out. Reversed the operation with the new ice maker and after a few minutes presto, we have ice.
Parts Used:
Refrigerator Ice Maker Assembly
  • Juan from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
252 of 339 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Stopped Working
It was pretty straight forward. Remove the two screws that hold the unit to the wall of the freezer. In my case, I had to use a different ice maker than what came with the frig. In order to install the replacement unit they sent a wire adaptor so it would attach to the existing wiring. That too was all fine and dandy. The only problem was that the end of the wire adaptor did not fit through the existing hole in the rear of the frig. I used a utility knife to cut through the thin metal lining. That worked just fine. However, I could not cut through the insulation because I could not reach it through the small hole. The excess wire was supposed to be pulled through the hole and out through the back of the unit. So now the excess is between the wall of the freezer and the insulation. The unit is working wonderfully. In fact, it is making more ice than I can use. I am very pleased with the replacement unit. This is the 3rd ice maker that has been in this frig. All the others had a design flaw that had a leak in the rear of the unit. This caused all the ice to form into a big block. The replacement unit has not had this problem so far. Thank you for allowing me to explain my situation so that maybe others may benifit from my experience. Thank you. Jack
Parts Used:
Replacement Ice Maker
  • JACK from MESA, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
163 of 179 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy fan
1. Removed the 7 nuts using the nut driver from the freezer back panel inside the freezer.
2. Remove the back panel. The evaporator motor and fan are located above the coils.
3. Unplug the wiring harness.
4. Remove the two gold mounting screws holding the motor and fan in place.
5. Remove the motor and fan including the brackets.
6. Install the new motor and fan onto the mounting bracket.
6a. Attach the green ground to the mounting bracket.
7. Screw the two gold screws back into the freezer.
8. Attach the new wiring harness. Note, the old harness had a mounting hole/space for it to connect to the wiring harness of the freezer. The new motor's harness was not long enough for this, so it is connected freely to the freezer harness.
9. Use the hair dryer to melt any ice that may have formed on the coils and hole where the fan goes.
10. Turn the freezer on to see if the fan turns on.
11. Reinstall the back panel.
All done!
Parts Used:
Evaporator Fan Blade Evaporator Fan Motor Kit
  • Jordan from Maumee, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
152 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Clicking sound then within a minute clicking again, not cooling.
UNPLUG REFRIGERATOR. Carefully remove relay from the side of the compressor. You shouldn't need a tool to do this, if it is hard you can gently pry the edge with a flat head screw driver just to loosen. Unplug white and red wires from relay, noting that the white wire goes in the hole with a #2 stamped beside it. Shake old relay, if it rattles like a baby rattler then it's most likely the problem. Replace wires into the new relay and plug back into the compressor.
Parts Used:
Compressor Start Relay
  • Melvin from Semmes, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
79 of 93 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped producing ice
First I removed ice maker and tested the micro switches and motor individually. Then checked the resistance of the heater element, and the thermostat. All components tested okay and worked individually. However when installed in the freezer the motor would not turn. and if you manually turned the gear in front, which should cycle everything,nothing would happen. Finally, I found one part that I had not checked, the thermal cut-off, and upon removing it, one wire fell off the small square piece. This wire was corroded. I replaced the unit in about 10 minuites and ice maker is working perfectly again.
Parts Used:
Icemaker Thermal Cut-Off
  • Jeremy from Peoria, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
60 of 75 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light socket melted around bulb
After unsuccessfully trying to change the blown light bulb I discovered that the plastic light socket had gotten so hot that it melted and permanently fused with the blown bulb. After my new socket arrived in the mail I just popped the temp control assembly out with a screw driver and removed the old socket and placed the new one in. Whole operation to 5 minutes.
Parts Used:
Light Socket
  • William from Alexandria, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
65 of 107 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Side-by-side .. freezer working, fridge not cooling
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc. After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself
Parts Used:
Defrost Timer - 60Hz 120V
  • Tad from Lancaster, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
46 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker died!
The repair for this was very simple, although it was a tight squeeze. The model I replaced the ice maker on was a side by side. First I removed the ice bucket so I could have more room to work with. Then I unscrewed 2 screws on the left side wall holding the ice maker in place. These screws had a 1/4" nut top on them so I used my socket driver for this. Then a quick disconnect of the wiring harness. Very Simple. I did the reverse to install the new unit. Total time was around 5 minutes or so. I now have ice again.
Parts Used:
Replacement Ice Maker
  • John from Las Vegas, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
45 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker stopped working
Reviewed the video on your website and followed the directions to the letter. Great video
Parts Used:
Refrigerator Ice Maker Assembly
  • Dennis from DEER LODGE, MT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
38 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator ran frequently and freezer door was sagging
I pulled off the old door gasket which came off really easy. I was hoping the new one would go on as easy as just popping it in place but it didnt work. I had to remove the inside door panel. The gasket wouldnt lay entirely flat in the inside groove so I used a bead of RTV around the entire circumference which helped to hold it in place while reattaching the panel back onto the door. The screws fit on the under side of the magnetic portion of the gasket. In order to access the screw holes the gasket has to be lifted which sometimes causes the gasket to pull from the lip on the back side of the panel making the RTV get everywhere. After every screw was in place and lightly tightened the panel had to be adjusted to allow for the proper closing of the door. This was the worst part, fortunatly the screws left a slight indentation of where they were before I removed them so it gave me a nice reference.
The hinge part of the new gasket requires a lubricant so it wont bind up when the door is closed. I didnt know about this until my order arrived and a part number was recommended for the type of lube. I just used Vasolene and it works fine.
The pin bearing was really easy. Just unload the contents from the door, mine was the freezer door. I popped off the cap covering the screws and removed the screws while holding the door so it wouldnt drop on the floor. Once off I used a flat head screwdriver to pry out the old one and a light tap of a hammer to replace it with the new. I put it all together the way it came off.
Now my fridge runs much less and the freezer door doesnt sag.
Parts Used:
Fresh Food Door Gasket Door Hinge Pin Bearing
  • Dale from Pevely, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
38 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old ice maker had stopped working properly. The cycle was inconsistent, and inlet water would run over existing cubes in the tray, before they were dumped into the dispenser box.
This was really simple, much like changing a light bulb. Two bolts loosened beneath the old unit to allow it to be lifted off and free. The power supply plug was easily disconnected. The new unit was then placed onto the loosened bolts, power supply reconnected and secured with the supplied wire tie. A small angled bracket was removed from the old and reattached to the new as a support toward the from of the unit. The cycle adjuster was backed off a 1/2 turn as per the instructions....and the next morning....new automatic ice. Life is good!
Parts Used:
Replacement Ice Maker
  • Daniel from Baldwin City, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
28 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no cooling in fridge or freezer due to bad defrost timer
i removed the 4 screws holding cover. removed two screws holding timer. unplugged timer. plugged in new one. reassembled.
Parts Used:
Defrost Timer - 60Hz 120V
  • Todd from pottstown, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
29 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old icemaker would not cycle to make ice.
I had already removed the ice maker by loosening the two screws with a 1/4" nut driver, in order to compare the design and style to the intended replacement for size and critical measurements. The replacement was almost identical. The wiring harness was 2-3" longer than the original, but after snaping the wire plugs together I simply curved the wire up and to the left to be out of the way. The hanging brackets are slotted and it was easiest to slip the back hanger over the head of the screw and let it slip down, then the front hanger was already to line up even though you can't see the screw with the ice maker in the way. I had to transfer an L-shaped metal bracket to the bottom side, matching the old assembly, and adjusting it to hold the bottom side away from the freezer compartment a little so it would hang level and secure. You have to snug the two screws with a screw driver or 1/4" nut driver by feel, since you can't see them with the icemaker in place. It took about 10 minutes to take out the old and another 10 to put in the new. We now have a full bin of ice, and the old plastic trays have been retired. I should have done this a year ago.
Parts Used:
Replacement Ice Maker
  • David from Cedar City, UT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
24 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Evaporator Fan Burnt Up
The fan motor all but caught the inside of the freezer on fire . Had to remove then clean, and I mean clean the walls of the freezer . Then had to pry out the old fan without breaking anything . Replacement of new fan was quick and easy because all the parts that I needed were in the bag
Parts Used:
Evaporator Fan Blade Evaporator Fan Motor Kit
  • ROY from PENSACOLA, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
28 of 38 people found this instruction helpful.
Was this instruction helpful to you?