Fridge was getting warm while the freezer was cold and running constantly.
0 of 2 people
found this instruction helpful.
-
Jeremiah from Northglenn, CO
- Easy
- Less than 15 mins
-
Nutdriver
After testing and eliminating the temperature control and the timer as the problem, I turned to the thermostat. I had to wait for the ice buildup to thaw and then could remove the rear freezer panel (this was the 3rd time: first, to discover the ice buildup causing the problem, second when it came back after a complete thaw and test the
... Read more
thermostat, and this time to put the Partselect thermostat back in). My thermostat was visibly damaged from water melting into ice and expanding the casing and eventually breaking one of the connections. I connected the thermostat connection wires (not recommended) to get by while ordering the part, which shipped faster than local repair places could get it from their warehouses, and at a fraction of the cost. I'm really impressed with partselect's fast service and all the knowledgable customers who have explained how they installed them. I now have an intimate knowledge of how my fridge works and saved hundreds in repair, or twice that in replacement. Thanks!
Read less
Was this helpful?
Thank you for voting!
Freezer was building up ice. Running constantly.
0 of 3 people
found this instruction helpful.
-
eugene from norwalk, CT
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
Parts Select is an excellent source for help and parts identification. I highly recomend them.
My first option was to replace the defrost timer.
After still getting ice and frost buildup in freezer I decided to replace the defrost thermostat.
Remove all shelves. Losen icemaker if applicable. Remove light cover and bulb. R ... Read more emove all screws securing rear vertical cover. Carefully move back panel, disconnect icemaker and bulb assembly. carefully remove styrofoam cover at upper left and remove defrost thermostat. I tested the thermostat and found it was defective. It would not close circuit after being placed in a working freezer. Reverse procedure to replace thermostat.
This solved the problem
My first option was to replace the defrost timer.
After still getting ice and frost buildup in freezer I decided to replace the defrost thermostat.
Remove all shelves. Losen icemaker if applicable. Remove light cover and bulb. R ... Read more emove all screws securing rear vertical cover. Carefully move back panel, disconnect icemaker and bulb assembly. carefully remove styrofoam cover at upper left and remove defrost thermostat. I tested the thermostat and found it was defective. It would not close circuit after being placed in a working freezer. Reverse procedure to replace thermostat.
This solved the problem
Read less
Was this helpful?
Thank you for voting!
Adjust the door hinge for new gasket.
-
Kinnett from Gaffney, SC
- Easy
- 1- 2 hours
-
Screw drivers
Loosened the screws, removed the old gasket. Cleaned contact area and installed the new gasket. Adjusted the door hinge and used a hair dryer to let the new gasket relax and seal.
Was this helpful?
Thank you for voting!
would not defrost
-
Nick from Silver Spring, MD
- Really Easy
- 30 - 60 mins
-
Screw drivers
Replace thermostat and show and tell made it easy.
Was this helpful?
Thank you for voting!
Would not freeze or defrost
-
RONALD from Sevierville, TN
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Unplug freezer let stand all night to defrost. Remove the tray cover which is located on the upper back area inside the freezer.( 3 twist fittings remove it ). Remove the upper stainless steel panel which is secured with 6 screws. This will drop down exposing the condenser. Note all the wires and fan will stay attached to the stainless
... Read more
steel panel, this panel will drop down no need to unplug anything. On the left upper side next to the condenser you will see the thermostat. Two color coded wires. Remove the thermostat and install the new one at the same location.
Read less
Was this helpful?
Thank you for voting!
Freezer was no longer keeping items frozen,
-
Philippa from New York, NY
- Easy
- 30 - 60 mins
-
Screw drivers
I followed the You-Tube instructions, removed the ice from the compressor and replaced the thermostat with the part I received from Part Select. What I took out was a part that was very much inferior to the replacement part. The repair saved me a lot of money for a new freezer and it was not difficult to do following the video. Now the f
... Read more
reezer runs better and quieter than ever. Thank you Parts Select.
Read less
Was this helpful?
Thank you for voting!
Freezer was warm
-
Charles from Macomb, MI
- Really Easy
- 30 - 60 mins
-
Screw drivers
I first noticed my ice cream getting soft. Then 2 days later the alarm went. I emptied the freezer, opened the panels and saw no frost. I saw that 99% of issues were resolved with a defrost timer and thermostat so I ordered those. I have to say the parts came quickly and they went in very easy. My freezer seems to be in the 1% categor
... Read more
y though. It's still not cooling even though I can measure the temperature at the front of the evaporator coil is cold but by the end of the coil it's almost room temperature. I think a repairman is called for.
Read less
Was this helpful?
Thank you for voting!
Freezer freezes up; lower unit to warm
-
David from Front Royal, VA
- Easy
- 15 - 30 mins
-
Nutdriver
Replaced freezer defrost thermostat. Unit worked perfectly.
Was this helpful?
Thank you for voting!
Fan in freezer quit
-
Dan from Woodstock, GA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
This was an easy job. First remove the ice maker, if you have one. Mine was mounted with just two screws. Loosen these screws, unplug the power cord at the connector and then lift the ice maker off. Remove the light bulb cover and the light bulb, just so you dont break it. Remove two hex screws and the back cover can be removed. My fan wa
... Read more
s mounted in the middle of a bracket retained between two rubber bushingings. Just push the fan blad of the shaft and pull the motoer out. Dissonect the power cord at the connector. My moter was differant than the replacement on the mounting so with the removial of the two screws on the motor I was able to exchange the upper and lower cast motoer housings. Reverse the assembly process and you good. Mine is running great.
Read less
Was this helpful?
Thank you for voting!
won't start repaced the run capacitor didn't solve the problem so I ordered a defrost timer
-
Curtis from Winlock, WA
- Really Easy
- 15 - 30 mins
I watched the videos (they really help) and followed the steps. Everything went smooth with no surprises
Was this helpful?
Thank you for voting!
not cold enough
-
Gary from Hudson, FL
- Really Easy
- 15 - 30 mins
-
Screw drivers
per the video..easy installation....unfortunately the temperature did not improve. We still have a refrigerator temp in the upper freezer.....and a "cooler" in the refrigerator section
Was this helpful?
Thank you for voting!
Frige and freezer not cooling
-
FRANK from BRADENTON, FL
- Really Easy
- 15 - 30 mins
-
Nutdriver
I should have ordered start kit instead of start capacitor. The start cap astir did not fix problem so I ordered kit. Compasator comes as part of kit. Followed enclosed instructions. Cut existing wires and reconnected new wiring. Simple as that. It's a plug in item. Now worried it may be working to good. Freezer down to 10 deg. Watching
... Read more
to see if compressor is running to long. Seems ok lol. Wife hates me now. She wanted new frige.
Read less
Was this helpful?
Thank you for voting!
compressor not running
-
wilson from indialantic, FL
- Really Easy
- Less than 15 mins
-
Nutdriver, Wrench (Adjustable)
thanks to all of the people who had the same problems I was able to make a quick fix on my fridge. I pulled the back cover off and found the compressor not kicking on so I replaced the start cap. and im back in bussiness.
Was this helpful?
Thank you for voting!
the compressor capacitor overheated
-
Bart from goldsboro, NC
- Really Easy
- Less than 15 mins
-
Screw drivers
it was great. I ordered the capacitor for my frigidaire frig and it arrived
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
Was this helpful?
Thank you for voting!
refer quit cooling and so did freezer
-
jerry from petaluma, CA
- Really Easy
- Less than 15 mins
I replaced the defrost timer,defrost thermostat,and run cap.as it turned out the compressor went bad. I dont know the model because but the time I got this review I replaced the refer with a knew one . two weeks living out of coolers was so much fun !!!!!!!!
Was this helpful?
Thank you for voting!