Freezer was running too warm
6 of 8 people found this instruction helpful.
  • Jeanne from SAN ANTONIO, TX
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Was this helpful?
Thank you for voting!
Refigerator Not Staying Cold
5 of 5 people found this instruction helpful.
  • Marsha from BEVERLY, MA
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Wrench set
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
Was this helpful?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
5 of 7 people found this instruction helpful.
  • gary from ARANSAS PASS, TX
  • Easy
  • 30 - 60 mins
  • Nutdriver
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Was this helpful?
Thank you for voting!
Refrigerator = Circulator Fan Motor Made A Real Loud Noise !!
4 of 5 people found this instruction helpful.
  • Jeff from COTTONWOOD, AZ
  • Very Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
Remove All Interior Metal On Inside Of Upper Part Of Fridge, Then Remove Fan & Brackets. There Was A Total Of 6 Screws & 4 Electrical Wires That I Had To Remove To Have This Fan Ready To Replace. Then I Ordered A New Fan From This Excellent Online Appliance Part Select Ware House. And From There It Was Delivered To Pine Shadows MHC In Cottonwood, AZ Northern Arizona Largest Mobile Home Community In This Beautiful Verde Valley Desert. Where We Have Sunshine Every Day Of The Year. And I Thank You For The Prompt Response That Your Ware House Performed That Evening. From Yours Truly Jeff
Was this helpful?
Thank you for voting!
Freezer fan stoped working.
6 of 11 people found this instruction helpful.
  • RICHARD from LANCASTER, PA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Took longer to take out the shelves and the 10 screws holding the cover on then to replace the fan.
Local parts supply told me it would take two weeks to get the fan mator,ordered it from parts select and had in a couple days.
Was this helpful?
Thank you for voting!
freezer would frost up and not get cold enough to keep frozen.
3 of 3 people found this instruction helpful.
  • Richard from SLIDELL, LA
  • Very Easy
  • 15 - 30 mins
  • Screw drivers
Removed shelves ,removed panel on interior back wall with Philips screwdriver ,unplugged wire terminals slid thermostat off coil ,then reversed process to complete installation.
Was this helpful?
Thank you for voting!
Defrost Timer
4 of 6 people found this instruction helpful.
  • DAVE from LOS RANCHOS, NM
  • Very Easy
  • Less than 15 mins
  • Screw drivers
The old defrost timer started making a screeching noise (probably bearings going out). The replacement part was a cinch to install. When I initially spoke to a PartsSelect person, they said the part number I gave them was not consistent with my old '94 Tappan Freezer. They were able to still find the proper replacement part number. Th e video that was on-line helpful also.
Was this helpful?
Thank you for voting!
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
3 of 3 people found this instruction helpful.
  • Tunis from NOLANVILLE, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
Was this helpful?
Thank you for voting!
bad gasket seal
3 of 3 people found this instruction helpful.
  • Jason from WHITEWATER, WI
  • Very Easy
  • 30 - 60 mins
  • Screw drivers
removed old one and replaced with new
Was this helpful?
Thank you for voting!
No problems
2 of 2 people found this instruction helpful.
  • Steve from PRAIRIEVILLE, LA
  • Really Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
It went exactly like your on line video. It took longer to defrost the freeze than it did to make the parts change out.
Was this helpful?
Thank you for voting!
Freezer not cooling due to icing up of coil.
2 of 2 people found this instruction helpful.
  • Thomas from GRANBURY, TX
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Was this helpful?
Thank you for voting!
old fan very noisy
2 of 2 people found this instruction helpful.
  • Stephen from CHILLICOTHE, OH
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
easy and fast
Was this helpful?
Thank you for voting!
Cooling coils would ice up and fridge would warm up
2 of 3 people found this instruction helpful.
  • Richard from Tehachapi, CA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I removed the shelves in the freezer, took out the five 1/4" screws and lifted off the cover. It was a simple matter of using a blow drier to remove all the ice, then unplugging the two wires and unclipping the thermostat from the upper cooling tube. Then clipped the new one on and reconnecting the two wires.

Works great!!!
Was this helpful?
Thank you for voting!
Coils were freezing up. Defrost cycle not working
2 of 3 people found this instruction helpful.
  • Stirling from FORT WORTH, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
First unplug freezer, then disconnected wires from timer.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Was this helpful?
Thank you for voting!
The freezer was too warm. The fan was running: the diagnosis tool did not work!
2 of 3 people found this instruction helpful.
  • Xavier from Philadelphia, PA
  • Easy
  • Less than 15 mins
  • Screw drivers
I used the tool at Partselect that in theory allows diagnostic of the problem to be repaired. The result was that more tan 90% of the time with the introduced symptoms it had to be the thermostat. I order the part, got it quickly and installed. It did not fix the problem. So, be careful with the diagnostic tool, because it is just bas ed on what most people buy when they have a particular problem. Videos for installation are great. If diagnosis was better, this would be fantastic. In my case there might be a different problem.