Glass plate inside microwave broke
2 of 3 people found this instruction helpful.
  • Linda from HAYWARD, CA
  • Very Easy
  • Less than 15 mins
Part select made it very easy for me to purchase a replacement plate, which I didn’t think I was going to be able to find so thank you part select for having what I needed
Was this helpful?
Thank you for voting!
Microwave operated but did not heat
3 of 10 people found this instruction helpful.
  • Donald from Oak Ridge, TN
  • Easy
  • 1- 2 hours
  • Screw drivers
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.
Was this helpful?
Thank you for voting!
My turntable shattered
  • Terry from New York, NY
  • Really Easy
  • Less than 15 mins
Partselect sent me the right thing in two days! The whole process was easy as pie.
Was this helpful?
Thank you for voting!