DA9101 Speed Queen Washer - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Cold water keep entering the tub, I had to shut off the supply line.
2 of 2 people
found this instruction helpful.
-
Kenneth from CARLISLE, PA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
I order a water inlet valve from this site It was the best buy around. The email from the site part came with a video how to change it. It was a 15 minute job. One 5/16 nut driver to remove the inlet valve and pliers to remove the hoes from the valve. Easy off easy on.
Was this helpful?
Thank you for voting!
The fill stream on my 20 plus year old Maytag washer had slowed to a trickle. The hot water flow was fine, but the cold water flow was a trickle and there was a whining/groaning noise when the tub water was filling. We decided from reading other repair stories on your site that our washer had a mal
2 of 3 people
found this instruction helpful.
-
Anne from Lexington, KY
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers, Socket set
We turned off the water, removed the hot and cold water hoses from the machine, then unscrewed the metal plate on the back of our washer that was covering the water inlet valve. Next we removed the output hose and pulled out the inlet valve. As we unhooked each electrical wire we immediatley hooked it to the same location on the new inlet
... Read more
valve. Then we rehooked the out put hose and reversed our steps to finish the job. Before putting the plate cover back over the inlet valve we filled the machine with cold water and ran it through all cycles to make sure we didn't have any leaks. The pictures/insturctions that came with the new part were helpful.
This was the first repair job that our 20 year old Maytag washer has needed, and it was nice to be able to do the job ourselves. Reading other customers's repair stories on your web site helped us diagnose our problem. I found it easy to locate and order the right part and it arrived two days after being ordered.
This was the first repair job that our 20 year old Maytag washer has needed, and it was nice to be able to do the job ourselves. Reading other customers's repair stories on your web site helped us diagnose our problem. I found it easy to locate and order the right part and it arrived two days after being ordered.
Read less
Was this helpful?
Thank you for voting!
no water thru valve(cold)
1 person
found this instruction helpful.
-
Billy from Alamogordo, NM
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers
un hook electric and shut off water:
had to remove top of washer
remove two screws holding valve in place
un hook water line and elec. wires from valve
reverse to put new valve on
Billy Myers
Alamogordo,NM 88310
had to remove top of washer
remove two screws holding valve in place
un hook water line and elec. wires from valve
reverse to put new valve on
Billy Myers
Alamogordo,NM 88310
Was this helpful?
Thank you for voting!
No "HOT" water when hot water was selected.
1 person
found this instruction helpful.
-
Elias from Glendale, CA
- Really Easy
- 30 - 60 mins
-
Screw drivers, Socket set, Wrench set
First you turn off the main water supply or turn off the valves at the wall behind the washer unit. Second you disconnect the hot and cold water lines going to the washer unit valve. You then use 1/4 closed end wrench to remove one screw. Then you use a flat head screw driver to remove the two screws holding the valve in place. At this
... Read more
point use a 1/4 socket drive to loosen the clamp that is holding the hose that feeds water to the valve. Remove the hose. Then you disconnect the four wires and re-connect the wires to the new valve. Re-install the hose to the valve. Then you are ready to put it all back together.
Read less
Was this helpful?
Thank you for voting!
The washer was making an frightening noise as it attempted to shut off the water
2 of 4 people
found this instruction helpful.
-
Michael from CHARLESTON, SC
- Really Easy
- 1- 2 hours
-
Nutdriver, Screw drivers
Terrified that the washer water value would blow due to the noise... Diagnosed the problem, ordered the part and it took only 10 minutes to fix. The hardest part was moving the washer in the confined space, which required moving the driver out and sliding the washer at a 45° angle in order to reach the access panel. Once access gained i
... Read more
t was straight forward. Step 1 removed fill hoses from supply. Backed the valve assembly out; detached water hose from value assembly with nut driver; detached wires'; value released; added new value and reverse process. Checked for leaks, reassembled fill hoses with new washers (stainless steel hose), ran cycle, checked for leaks, replaced washer in original position Need commend the video producer and repair person in the video. The narrative gave me the confidence that, Yes, I can do this.
Read less
Was this helpful?
Thank you for voting!
Slow cold water fill; buzzing of inlet solenoid
1 person
found this instruction helpful.
-
Michael from Beaverdam, VA
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Other guys have already spelled out in fine detail how to do the actual replacement. What I would add is this: First, I promised I wouldn’t swear during this repair. Second, I got everything I needed together including tools, a small bucket and some old newspaper to soak up the water that is sure to spill. I bought 6 foot stainless steel
... Read more
hoses to replace the old rubber ones. THIS IS HIGHLY RECOMMENDED as the last thing you need is a burst water line. Shorter hoses limit the distance you can move the washer without disconnecting them. The directions were wrong in that I did not need (nor could I use) the plastic sleeve over the outlet tube. So I very carefully had to pry this off without breaking the plastic bushing. And I had bent the clamp securing the outlet hose to the valve, and had a devil of a time getting it back on properly, so you may want to have a small tubing clamp handy as a replacement. Also, I checked for leaks before putting the valve back in place by holding it very carefully, powering up and turning the washer on and off a few times. Keep your fingers and sheet metal away from the terminals or your promise not to swear will be null and void! The last thing is that when I get into a project I go all the way, which meant pulling the washer all the way out and cleaning the floor and all the dust behind it, and even cleaning the washer itself. The result is my Maytag works like new, fills fast without the buzz and looks new, too. I love it when a plan comes together.
Read less
Was this helpful?
Thank you for voting!
Hot water inlet valve was cracked and leaking
1 person
found this instruction helpful.
-
David from ROWLEY, MA
- Very Easy
- 15 - 30 mins
-
Nutdriver, Wrench (Adjustable)
Shut off the electricity (pulled thee plug). Working from the rear of the washer. Removed water hoses with Stillson wrench. Removed two self tapping screws with nut driver to get to the assembly. Slipped off the wires lugs one at a time from thee old assembly and slipped them onto the new valve assembly in the same location. Installed the
... Read more
new assembly. Attached the water hoses to the new inlet valves. Note: My washer had the hot and cold valves identified on the washer. The replacement valve assembly was marked hot and cold (H, C.). which was the reverse of the marking on the washing machine. Go by the marking on the washing machine.
Read less
Was this helpful?
Thank you for voting!
The water inlet valve was leaking water into the tub - slowly filling it up
1 person
found this instruction helpful.
-
John from Cedar Park, TX
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
After disconnecting the power and removing the input hose connections I was able to remove the valve assembly through the back panel. I then removed the wires from the valve and disconnected the outlet hose. I removed the old valve and replaced it with the new one. Then reattached the outlet hose and 4 wires to the new valve. The assembly
... Read more
then was reinserted into to the back panel and screwed into place. Reconnect the input hoses and plug it in and it's ready to be tested for leaks & used. (I had no leaks, BTW. A little silicone grease on the fittings made reassembly go easier but it's not needed. )
Read less
Was this helpful?
Thank you for voting!
Small water leak from the water inlet valve
1 of 2 people
found this instruction helpful.
-
Bryan from Lodi, WI
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers, Socket set
Removed 2 screws on the bottom of the front of the washer and pried the front off. Then removed 2 more screws for the top of washer and rocked it back to expose the water inlet vavle. Removed the water inlvet vavle and replaced it. Then put it all back together. Done
Was this helpful?
Thank you for voting!
Cold water would not enter washer.
1 of 2 people
found this instruction helpful.
-
Tevis from Albemarle, NC
- Really Easy
- 15 - 30 mins
-
Pliers, Screw drivers, Wrench set
Change the position of electrical connection on inlet valve before installation to match positions of old valve. Shut off electricy and water to washer. Disconnected water hoses, and power wires to old valve. Removed old valve and installed new valve exactly as installed on old valve. Washer operated perfectively
Was this helpful?
Thank you for voting!
Washer tub overflowed with water after turned off and machine not used for several days.
1 of 2 people
found this instruction helpful.
-
Robert from Amenia, NY
- Really Easy
- Less than 15 mins
-
Nutdriver, Pliers
Simple removal of the mounting plate holding the old valve to the rear of the machine followed by disconnection of the water hose to the washer from the valve and unplugging of four electrical connections. Reattached the new valve to the water hose and then reattached the new valve to the mounting plate, finally reconnecting the wiring co
... Read more
nnections (4). Installation completed by reattaching the valve mounting plate to the washer. The diagnosis was confirmed by blowing into the old valve's water inlet. Air would pass through the valve, confirming that it did leak when the valve was closed. Air blown through the new valve prior to installation would not pass through the new valve.
Read less
Was this helpful?
Thank you for voting!
Hot water would not full shutoff during cycles, causing over flow
1 of 2 people
found this instruction helpful.
-
ALISA from Kathleen, GA
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
When the part came in, it was just a matter of getting the old part out, and replacing it! Incredibly smooth---the hold down screws were obvious, so once I got them out---the part came out of the machine, I disconnected the two control wires, reconnected them to the new part---and reinstalled!
Was this helpful?
Thank you for voting!
Low cold water flow during fill
1 of 2 people
found this instruction helpful.
-
Jeff from Diamond Bar, CA
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
Part shipping was great got here in two days-
I pulled off Front panel (two screws) and lifted Top panel (2 screws) and disconnected the inlet hoses. I removed the old Inlet valve. (1 scew and valve to tub hose connection).
Before Installing the new valve, i shifted the connector positions on the selenoids to match ... Read more the old valve. and installed by reversing the steps. All went very smooth. Thanks, It was easy.
I pulled off Front panel (two screws) and lifted Top panel (2 screws) and disconnected the inlet hoses. I removed the old Inlet valve. (1 scew and valve to tub hose connection).
Before Installing the new valve, i shifted the connector positions on the selenoids to match ... Read more the old valve. and installed by reversing the steps. All went very smooth. Thanks, It was easy.
Read less
Was this helpful?
Thank you for voting!
Water would not shut off. t
1 of 2 people
found this instruction helpful.
-
LADDIE from HUTSONVILLE, IL
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers, Socket set
Followed web instructions.
Was this helpful?
Thank you for voting!
Water inlet valve had a crack and was leaking water.
1 of 2 people
found this instruction helpful.
-
Eric from Brook Park, OH
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench (Adjustable)
I first shut off the cold and hot water hoses so that no water would run while replacing the part. After that I made sure to unplug the washer .Then I removed the plate that was holding the water inlet valve with a 1/2 " nut driver ,I think there were four bolts .Then I removed two more bolts from the center of the plate that were holding
... Read more
the water inlet valve.I then disconnected one 1/4 " screw or I should say loosened one which held the main water hose going into the washer which then released the part ,except from four wires. I then took one wire off at a time and attached to the new part one at a time.Finally, I was finished and reconnected everything .It worked perfected !I'am very happy and pleased . This washer is over 25 years old and still runs .
Read less
Was this helpful?
Thank you for voting!