Sticking Light Switch
122 of 178 people found this instruction helpful.
  • Jonathan from Lilburn, GA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
I applied some tips learned by reading other reviews. So before I started I grabbed my trusty vise grip pliers and a small screw driver. I locked onto the switch actuator, the part that the refrigerator door pushes in, with the vise grips and pulled on it just hard enough to get the screw driver inserted in the right side to push in the c atch clip so the switch could be pulled out further each time the catch clip was depressed to the next detent. Then I used the screw driver on the left site to encourage the switch past the detents on the left and very quickly the switch was out of the mount. The wires from the refrigerator pulled out with the old switch. I unplugged the old switch from the wires and plugged in the new switch and shoved the new switch back into the mount, wiggled it a couple of times to make sure it was secure and the job was done. Once I applied the vise gripes at first, the whole job took less than a minute.
Was this helpful?
Thank you for voting!
refrigerator was not cooling but the freezer worked fine.
93 of 110 people found this instruction helpful.
  • Wanda from Cabins, WV
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
My husband put on the defrost timer. At first I thought the part was not going to fix the problem. After about 5 hours my refrigerator was still warm. I went to work and when I got home that evening my refrigerator was cooling and down to 28 degrees. So if you replace this part wait at least 12-24 hours. Give it time to stablize. My husband says it has to go through its cycle. It works on a 24 hour timer. My refrigerator is working fine and this has saved me alot of money. My husband says, once you put on the timer you may have to use a flat screwdriver and turn the small dial clockwise one click to start it. He removed the kick grill and replaced the part. Dont forget to shut breaker off to replace this part. Turn power back on and start the timer. We are so happy that we now have a working refrigerator.
Was this helpful?
Thank you for voting!
ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.
91 of 132 people found this instruction helpful.
  • Gerald from Benicia, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple.
Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use.
The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap.
After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
Was this helpful?
Thank you for voting!
Ice maker stopped working
84 of 117 people found this instruction helpful.
  • Dan from West Bloomfield, MI
  • Really Easy
  • Less than 15 mins
  • Nutdriver
I unplugged the electrical connection. Then I removed the 2 screws holding the icemaker in place. I lifted out the old icemaker unit and put the new one in place. Then put the 2 screws back in and plugged in the new unit.

The icemaker started making ice very soon after turning the unit on.
Was this helpful?
Thank you for voting!
broken ice maker part
78 of 107 people found this instruction helpful.
  • Laura Beth from Mandeville, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
used a screwdriver to remove screw and unplugged part. Plugged in new one and secured with a screw.
Simple
Was this helpful?
Thank you for voting!
display showed dE
75 of 119 people found this instruction helpful.
  • Nancy from Hamburg, NY
  • Easy
  • Less than 15 mins
  • Nutdriver
popped off front grille, removed 2 screws for bracket, then had to remove one screw for timer. unplugged old timer, reversed procedure, all works.
Was this helpful?
Thank you for voting!
Ice maker quit making ice
40 of 53 people found this instruction helpful.
  • Jeffrey from Bluefield, WV
  • Really Easy
  • 30 - 60 mins
  • Nutdriver
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
Was this helpful?
Thank you for voting!
Refrigerator section would slowly warm up.
39 of 50 people found this instruction helpful.
  • Gary from Palm Coast, FL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Reading other after action write-ups I diagnosed the problem to be either the defrost timer or defrost thermostat so I decided to replace both. The timer was hard to find. Turns out it was inside the kickplate grill which made it hard to demount and remount while maneuvering the wire connector around. Just took a few minutes longer tha n expected. The thermostat was inside the freezer compartment requiring the refrig to be off and defrosted (heavy ice buildup on the coils confirmed diagnosis). Had to cut old thermostat wires and reattach new with crimp style wire nuts (provided with thermostat). Directions said to use silicone sealant in wire nuts - NOT provided. Need to attach new thermostat on top of coils with tie wrap (not provided). Overall reasonably easy with great results. Parts arrived very fast.
Was this helpful?
Thank you for voting!
Quit making ice.
37 of 49 people found this instruction helpful.
  • Joe from Brentwood, TN
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.
Was this helpful?
Thank you for voting!
not making ice
33 of 38 people found this instruction helpful.
  • thomas from richmond, VA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
when the ice maker runs through its cycle, you should be able to hear the solinoid valve open, letting water into the ice maker. this was not happening for me. you can dissconnect the plug on the valve and put the two probes from a multimeter in the plug and set for AC volts. when the ice maker runs its cycle, at the end you should see t he meter jump as power is applied to the valve then turns off. this means you do have power to the valve so the valve is defective. turn off water supply to the valve, disconnect the water supply tube to the valve, remove the screw holding the valve, disconnect supply tube to icemaker then hook up supply tube to bottom of valve, screw braket back to refrig, install suppy back to valve, turn water back on and check for leaks and your ice maker should be working properly again.
these guys were really fast on delivery too!
Was this helpful?
Thank you for voting!
ice maker leaked water slowly and froze the cubes together
41 of 62 people found this instruction helpful.
  • Steven from Cave Creek, AZ
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Was this helpful?
Thank you for voting!
water appearing under refrigerator
31 of 36 people found this instruction helpful.
  • Larry from Dallas, TX
  • Really Easy
  • 1- 2 hours
  • Screw drivers, Wrench set
Unplugged the refrigerator and turned off the water to the ice maker valve. Removed the water line at both ends (small crescent wrench). Removed the cover from the water valve area (two Phillips head screws). Removed the valve (two screws - small nut driver) and pulled off the two electrical connections.

Installed the new valve with the reverse procedure though the holding screws didn't line up with the existing holes in the refrigerator metal frame. I let it go with one screw holding ... didn't have a drill with me to make a second screw hole.

Replaced the old water line (from the wall to the valve) with a steel-reinforced hose.

Cut the female metal connector from the old water line up to the freezer and it fit nicely into the push-in outlet from the new valve. Turned everything back on and waited for the ice maker to cycle.
To my dismay, the leak had been coming from the plastic line that goes from the valve up to the ice maker. It had split, spraying water. Replaced that and everything works fine.

Lesson learned: Don't assume water near the icemaker valve actually is from the valve or its water connections. Watch the whole system cycle a couple of times to see what's really happening. Glad to have a new valve but the basic problem was the icemaker tubing.
Was this helpful?
Thank you for voting!
Panel hot to touch between freezer & refrigerator. Motor hot, fan not rotating.
32 of 39 people found this instruction helpful.
  • Kimberly from Grandy, NC
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Unplugged refrigerator, removed three screws to take out part, disconnected the wires and removed bad unit. Removed fan blade from old unit and attached to the new unit. Attached wires, placed the new motor back in. Plugged it back in, within 20 minutes panel between freezer and refrigerator was cool to touch.
Was this helpful?
Thank you for voting!
Ice was melting and freezing in bucket
33 of 42 people found this instruction helpful.
  • John from Lodi, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
Was this helpful?
Thank you for voting!
Failed Icemaker
35 of 62 people found this instruction helpful.
  • GARY from PARRISH, FL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Wrench set
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
Was this helpful?
Thank you for voting!