Ice Maker was leaking
4 of 4 people found this instruction helpful.
  • Robert from Severn, MD
  • Really Easy
  • Less than 15 mins
  • Screw drivers, Socket set
Used socket set to remove screws. Removed the wire harness, then removed lift arm from old ice maker and then put lift arm on the new ice maker. Reinstall wire harness then installed back in freeze with the screws. Video was very helpful. I will do business with Partselect in the future. Shipping was very fast. Thanks Partselect
Was this helpful?
Thank you for voting!
leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day
4 of 5 people found this instruction helpful.
  • Linda from Johnson City, NY
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self
Was this helpful?
Thank you for voting!
Ice maker just stopped making ice
4 of 5 people found this instruction helpful.
  • Thomas from Valencia, PA
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same t ime to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.
Was this helpful?
Thank you for voting!
Water overflowing ice maker
5 of 8 people found this instruction helpful.
  • James from Denver, NC
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
Was this helpful?
Thank you for voting!
water spilling from the ice maker
5 of 8 people found this instruction helpful.
  • Warren from Phoenix, AZ
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
The whole job went smoothly,just the way others have described it. Unfortunatlly the water valve was not the problem. The problem was that ice had formed where the water enter's the tray . and therefore could not get into the ice forming area and just spilled into the refrigerator. I removed the ice maker(2 screws and cable connector.) le t the ice melt and reconnected all is well again.
Was this helpful?
Thank you for voting!
evaporator fan was noisy
6 of 11 people found this instruction helpful.
  • Dwayne from Gastonia, NC
  • Easy
  • 15 - 30 mins
  • Nutdriver
First I unplugged the refrigerator. Next item was the ice-maker; remove (3) screws and unplug it from the back wall. Third task is remove the (4) screws that attach the back wall of the freezer compartment. Lift the wall up enough to dislodge the center cooling shaft that the fan rides in and remove the rear wall. The last item is the fa n motor which is attached to the freezer wall by (2) screws and (3) wires which are easily removed. Change out the motor and reassemble freezer compartment .
Was this helpful?
Thank you for voting!
lights wouldn't come on/work in refrigerator
4 of 6 people found this instruction helpful.
  • Jane from Albuquerque, NM
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers, Socket set
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80.. .would have been at least $100 to have a repair person come to the house!
Was this helpful?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
3 of 3 people found this instruction helpful.
  • riley from CAVE CREEK, AZ
  • Really Easy
  • 15 - 30 mins
  • Pliers, Socket set
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Ref er to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Was this helpful?
Thank you for voting!
Fill cup broke.
6 of 12 people found this instruction helpful.
  • Aliki from Miami, FL
  • Really Easy
  • Less than 15 mins
Very easy to order from parts select. Took seconds to replace.
Was this helpful?
Thank you for voting!
Raplaced switch
5 of 9 people found this instruction helpful.
  • Winston A from Brooklyn, NY
  • Really Easy
  • Less than 15 mins
  • Pliers
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Was this helpful?
Thank you for voting!
part was missing
3 of 3 people found this instruction helpful.
  • Van from HARTFORD, WI
  • Easy
  • Less than 15 mins
  • Socket set
installed new part easy
Was this helpful?
Thank you for voting!
Ice maker stopped making ice
3 of 3 people found this instruction helpful.
  • Daniel from DAVISBURG, MI
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to reach 10 degrees F to operate.
Was this helpful?
Thank you for voting!
The refrigerator stopped running
4 of 7 people found this instruction helpful.
  • Barbara H. from South Hill, VA
  • Easy
  • 1- 2 hours
  • Screw drivers
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Was this helpful?
Thank you for voting!
Ice maker stopped functioning
3 of 4 people found this instruction helpful.
  • richard from colorado springs, CO
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Socket set
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Was this helpful?
Thank you for voting!
Ice maker "exploded"!
5 of 10 people found this instruction helpful.
  • Sam from Kissimmee, FL
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Calrod element shorted, arc left burn marks in freezer, harness was burned. Replaced icemaker and wiring harness. Shut off arm [wire frame element] replaced, new version of the wire shut off arm does NOT require the old plastic ice level sensor to be installed on the new shut off arm.