Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
3 of 3 people found this instruction helpful.
  • riley from CAVE CREEK, AZ
  • Really Easy
  • 15 - 30 mins
  • Pliers, Socket set
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Ref er to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Was this helpful?
Thank you for voting!
part was missing
3 of 3 people found this instruction helpful.
  • Van from HARTFORD, WI
  • Easy
  • Less than 15 mins
  • Socket set
installed new part easy
Was this helpful?
Thank you for voting!
Ice maker stopped making ice
3 of 3 people found this instruction helpful.
  • Daniel from DAVISBURG, MI
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to reach 10 degrees F to operate.
Was this helpful?
Thank you for voting!
crisper rails broke
4 of 6 people found this instruction helpful.
  • APRIL from CUYAHOGA FALLS, OH
  • Really Easy
  • Less than 15 mins
  • Socket set
The parts came within two days. They were very easy to instlall. I had to remove the screws from the refridgerator and attach them to the new rails and install. Thats it.. will be buying more parts soon..
Was this helpful?
Thank you for voting!
Raplaced switch
5 of 9 people found this instruction helpful.
  • Winston A from Brooklyn, NY
  • Really Easy
  • Less than 15 mins
  • Pliers
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Was this helpful?
Thank you for voting!
Fill cup broke.
6 of 12 people found this instruction helpful.
  • Aliki from Miami, FL
  • Really Easy
  • Less than 15 mins
Very easy to order from parts select. Took seconds to replace.
Was this helpful?
Thank you for voting!
Ice maker stopped functioning
3 of 4 people found this instruction helpful.
  • richard from colorado springs, CO
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Socket set
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Was this helpful?
Thank you for voting!
The refrigerator stopped running
4 of 7 people found this instruction helpful.
  • Barbara H. from South Hill, VA
  • Easy
  • 1- 2 hours
  • Screw drivers
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Was this helpful?
Thank you for voting!
Ice maker stopped working
3 of 4 people found this instruction helpful.
  • Raymond from Panama City Beach, FL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
After checking the water valves ordered new ice maker. received the part three days after ordering! Clearing out food, removing the old one and installing the new unit took under 15 minutes. Everything went fine.
Was this helpful?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
3 of 4 people found this instruction helpful.
  • David from Hemet, CA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull t he connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Was this helpful?
Thank you for voting!
cold control knob was missing
4 of 7 people found this instruction helpful.
  • Walton from Albion, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
place knob on to control stem and then fasten with screw
Was this helpful?
Thank you for voting!
Ice maker "exploded"!
5 of 10 people found this instruction helpful.
  • Sam from Kissimmee, FL
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Calrod element shorted, arc left burn marks in freezer, harness was burned. Replaced icemaker and wiring harness. Shut off arm [wire frame element] replaced, new version of the wire shut off arm does NOT require the old plastic ice level sensor to be installed on the new shut off arm.
Was this helpful?
Thank you for voting!
Ice cubes in bin frozen into big lumps due to water leaking into bin from icemaker. Lining of icemaker cube tray worn and damaged allowing leak.
3 of 4 people found this instruction helpful.
  • Ross from Sun Lakes, AZ
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Pull refrigerator out from wall to shut off water and power. Remove ice bin, pulling front down then out. Remove screw at bottom of icemaker, then pull down to release two clips, Pull out a couple inches to get hand behind icemaker to release wiring harness connector. (squeeze top and bottom to release clips). Remove unit. Remove wiring harness and wire bail from old unit and install on new unit. Reverse steps to install new unit. Make sure ice bin is fully inserted, or unit will not function.
Was this helpful?
Thank you for voting!
changed the light bulb still would not work so I figured it was the switch sure enough.
3 of 4 people found this instruction helpful.
  • anthony from HAVELOCK, NC
  • Really Easy
  • 15 - 30 mins
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Was this helpful?
Thank you for voting!
Old Ice Maker failed
3 of 4 people found this instruction helpful.
  • John from Gurnee, IL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I removed the old ice maker and during the short disassembly noticed a burned out connection to the heater element that allows the ice to be broken free of the tray and dumped into the bin. Part Select had a new unit to me next day! I had watched their short install video, and read some of the user comments, already. Re-installing the n ew unit was a snap, and just as the video had described except for the mount bracket. The only thing that concerned me was that the new unit did not immediately do anything. I began to investigate and found that the flexible water "chute" connection had ice in it! I unplugged the refer, unscrewed the water filter and drained it. I disconnected the water feed on the outside back of the unit as well to make sure water could flow easily to the ice maker port. I filled the water filter with boiling hot water and replaced it, I plugged in the refer, and reprogrammed the date and time. Several hours later I checked the ice maker and it was -- making ice!