The Icemaker failed to make ice
8 of 16 people found this instruction helpful.
  • Dean from Folsom, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement i cemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Was this helpful?
Thank you for voting!
evaporator coils iced up causing no cooling in freezer or fridge.
4 of 4 people found this instruction helpful.
  • Kenneth from Sweet Home, OR
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
First I disconnected the Power from the unit. Pulled out the freezer drawers and the ice machine used a 1/4 inch nut driver and removed the sheet metal from the back of the freezer exposing the evaporator coils. I defrosted the coils. Then I removed the two screws holding the defrost heater braket assembly and removed the two electrica l connections from it. I then installed the new heater put everything back together(reverse of installation)and it works like a brand new fridge and freezer.
Was this helpful?
Thank you for voting!
The vegetable pan was broken from closing the door on it too hard when still open
4 of 4 people found this instruction helpful.
  • John from Randle, WA
  • Easy
  • Less than 15 mins
I just slide the new one in place, using exsisting sliders. I had to remove the old grab handle from old pan and snap it into place on new pan.
Was this helpful?
Thank you for voting!
no ice made
5 of 8 people found this instruction helpful.
  • Robert from San Marcos, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of s crews had ice again !
Was this helpful?
Thank you for voting!
Lower door hinge cam worn out/door dropped, not sealing
3 of 3 people found this instruction helpful.
  • Frank from Las Cruces, NM
  • Easy
  • 30 - 60 mins
  • Socket set
Removed door contents to lower weight (good time to clean/disinfect door compartments), blocked and shimmed door up to correct fininished height. Removed lower hinge components (make sure shims positions are noted). Replaced w/new components and removed blocking. Easy job, should have done sooner.
Was this helpful?
Thank you for voting!
freezer coils would freeze
3 of 3 people found this instruction helpful.
  • Jerry from Grass Lake, MI
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Turned the power of to the fridge took the food out of the freezer put in the fridge took out all the shelves and took off the panel to get to the coils. I used a hair dryer and a shop vac to defrost the coils used the shop vac to suck up the water as the ice melted also put some paper towel in the drip tube so the water would not go to t he drip pan. Took off old defrost heater which was a single heater the new on was a double heater fished out the blue wire from the left side of compartment and ran it down the right side plugged both wires into the heater mounted it into place and put everything back. Turned on fridge and it has been working fine ever since. Thanks for the last person that did this I read his review and it really was that easy
Thanks Jerry
Was this helpful?
Thank you for voting!
handles had yellowed
3 of 3 people found this instruction helpful.
  • carl from WILLISTON, ND
  • Very Easy
  • 30 - 60 mins
  • Screw drivers
I pried the ends off handles. I removed the screws from the handles with a torx driver. The new handles fit perfectly and I put the screws in to fasten the handles and then slid the handle caps on.
Was this helpful?
Thank you for voting!
would not crush ice
3 of 3 people found this instruction helpful.
  • Larry from Mount Airy, NC
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
you must pay careful attention when taking the dispenser apart,especially the long rod that controls the deflector,but if close attention is payed to disassembly you should have no problem.
Was this helpful?
Thank you for voting!
Cold water dispencing was becoming slower and volume of ice was becoming less.
4 of 6 people found this instruction helpful.
  • Peter from Ashford, CT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
Shut water supply off, removed power plug from wall and removed electrical connector from valve. Unscrewed two plastic nuts which retained lines to old valve. Remove old valve and reinstalled new valve with one screw. Removed inserts from end of lines. (These inserts keep lines from deforming.). Trimmed and chamfered ends of lines reinst alled inserts and installed lines to new valve. Turned on watter, checked for leaks turned power on inserted glass for water received good flow. Ice maker did not receive water. Due to low flow of water to ice tray because of low flow with old valve, ice built up in flexable water delivery tube that goes from back of refrigator to ice tray. Removed tube ran under warm water removed ice blockage reinstall tube all working excelent. This iceing problem took about anouther 15 to 25 min to correct.
Was this helpful?
Thank you for voting!
Freezer was not freezing foods completely or making ice properly. It was running almost 24/7. It was not defrosting and ice was building up on the back wall. The refrigerator food drawers were freezing fruits and vegtables.
3 of 3 people found this instruction helpful.
  • Edward from Florida, MA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Great Service! Received the part the NEXT DAY!

We originally called a service technician. He came the next day and said the mother board was no good. He order a new one and replaced it a week later. Total part & labor cost: $185.00 (Remember we're without a working refrigerator the whole time the part is on order)
Two da ys later the freezer is doing the same thing. We call the tech again and he seems confused and says it could be the heating element, he'll order one at no charge and replace it for us free. He never comes back with the part and does not answer our 2 dozen phone calls. I checked the element myself and saw that the tube had been scorched, like a burnt out light bulb. Searched for parts on internet and found this great site. "Partselect.com"
REPAIR:
Refrigerator had been unplugged for a few days to defrost ice build up in freezer. First, I removed the shelves from freezer compartment, removed the back panel and removed screws holding heater element in place, I unplugged the two electrical leads and plugged in new part. AS EASY AS THAT !!!!! I reinstalled the screws to hold the element, installed the back panel and replaced the freezer shelves. I plugged the refrigerator back in and within hours the freezer started making ice again. It's been about 3 weeks and we have not had a problem since.
Fantastic Service and instructions and Inexpensive !!!! I will use this site again, if needed, and will recommemd to anyone who needs parts.
Was this helpful?
Thank you for voting!
cam closing washer broken
3 of 3 people found this instruction helpful.
  • David from Elk Grove, CA
  • Easy
  • 15 - 30 mins
  • Socket set
I propped up the door with 2x4 and shims to be level with the freezer door. Then removed the 2 screws holding the hinge to the main unit. Then removed the 2 screws holding the cam washer to the door.
Replacement was the reverse of disassembly. Be sure to tighten screws almost tight until both pieces are located correctly then fully t ighten. Lift up refrigerator door slightly to remove shims and wood block.
I did the replacement myself but was nervous that the door would fall off the block and shims. I recommend having another person hold the door closed during the process.
Was this helpful?
Thank you for voting!
Refrigerator cannot generate cool air
3 of 3 people found this instruction helpful.
  • HUAHUI from NEW HYDE PARK, NY
  • Easy
  • 15 - 30 mins
  • Screw drivers
I bought the GE Refrigerator about 4 years ago for about $1500. The defrost Heater failed about one year ago. Then I called local repair guy, he replaced the Defrost Heater and charged me about $250. Now it happened again. I think we should try it to fix it by myself. I found the parts from partselect.com, it costs me $50 with 2-3 days shipping. After it replaced, it works fine again.

Note: Symtom: cannot make cool air, Frozen area with frost on the wall. Regeriator "leaking water" on floor since iced food started to melt...

Solution: open the cover of the wall inside of frozen zone, use hot water to defrost it gradually. removed the failed Defrost Heater and replaced it with new one.

Note: after you defrost the area inside of the wall, your refrigerator will work normally without the Defrost heater without any issue about week while you are waiting for the parts coming.
Was this helpful?
Thank you for voting!
Water was not running out of dispenser but the ice cube maker was working
4 of 6 people found this instruction helpful.
  • Frank from Florham Park, NJ
  • Easy
  • 15 - 30 mins
  • Nutdriver, Wrench set
Well I Googled the problem to the dual inlet water valve. Luckily I found PartSelect for the correct part and the installation was simple. I now have both the cubes and water working properly from the dispense.
Was this helpful?
Thank you for voting!
evap coil freezing up every 2 weeks
3 of 3 people found this instruction helpful.
  • Rudolph from Arroyo Grande, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
removed 2 - 1/4" screws and 2 phillip screws to take off the evap cover, then 2 phillip srews to take out the defrost heater assembly, replaced and put everything back together. no problem.
I GOT THE PART SO FAST THAT I WAS SURPRISED TO SEE IT THERE!
Was this helpful?
Thank you for voting!
My wife called me at work and said the refrigerator was "peeing" on the floor.
3 of 3 people found this instruction helpful.
  • Jerry from Hurst, TX
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers
When I got home I pulled the refrigerator away from the floor, checked all the water lines for leak evidence, and then took the back panel off to check everything behind. The water valve was leaking at the hose insert locations. I turned off the water, spent less than 5 minutes disassembling the valve from the rerfrigerator, and got onl ine to buy another one. The part arrived several days before expected, and it took me less time to install the new part than it did to take the old one out. Now all I have to do is repair the floor damage I caused when pulling out the refirgerator!