would not crush ice
3 of 3 people found this instruction helpful.
  • Larry from Mount Airy, NC
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
you must pay careful attention when taking the dispenser apart,especially the long rod that controls the deflector,but if close attention is payed to disassembly you should have no problem.
Was this helpful?
Thank you for voting!
The dispenser water reservoir had a pin hole leak.
3 of 5 people found this instruction helpful.
  • Daniel from Genoa City, WI
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Wrench (Adjustable)
1. Turned off the water supply to the refrigerator.
2. Removed the front panel and disconnected the water line to the front left.
3. Removed the left rear (freezer side) panel and disconnected the reservoir from the main water supply input. This was a little tricky to figure out. You must push in the water line at the same ti me pushing in the coupling. Then pull the line out while keeping the coupling pressed in.
4. Removed the screw that holds the reservoir to the back of the refrigerator.
5. Pulled the old reservoir out and replaced it with the new one.
6. Basically the rest is the reverse of the above. It took a little bit to fish the lines through the original path they came.

Overall this was an easy repair. If I had known how the coupling in step 3 worked this would have been a 15-minute project.
Was this helpful?
Thank you for voting!
Broken Light Shield
3 of 5 people found this instruction helpful.
  • Jeffrey from Cumming, GA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Removed the Ice Maker container. Removed the one screw that held the remnant of the old light shield. Placed the new light shield in place and installed the screw. 5 Minutes from start to finish.
Was this helpful?
Thank you for voting!
heavy frost buildup in ice dispenser chute and door
2 of 2 people found this instruction helpful.
  • Robert from Rockford, IL
  • Really Easy
  • 15 - 30 mins
  • Pliers
After inspection of the new door recess assembly, I realized that I could use sidecutters (electronic assembly type) and 'clip' off the inward lock tabs of the old recess assembly and disengage it from the crank door arm without any further disassembly of the refrigerator door. It was easy to 'unhitch' the tang from the crank arm and wi ggle it out through the external opening of the ice/water dispenser compartment. I reversed the process and inserted the new assembly through the external opening of the compartment. The new door recess assembly snapped into place on the crank arm and fit tightly against the ice chute opening, correcting the issue caused by aging distortion of the old rubber seal cup portion of the door recess assembly.
Was this helpful?
Thank you for voting!
LIGHT SHEILD BROKE.
2 of 2 people found this instruction helpful.
  • PAUL from ALBUQUERQUE, NM
  • Very Easy
  • Less than 15 mins
SNAPPED THE NEW SHIELD IN PLACE. DONE!
Was this helpful?
Thank you for voting!
Light Shield Broke Off
2 of 3 people found this instruction helpful.
  • Travis from Hillsboro, OR
  • Really Easy
  • Less than 15 mins
  • Screw drivers
The light shield is only held in with a single screw, so it was the simplest install ever - unscrew the old light shield (in my case, the remaining piece of the light shield), put the new shield in place, and screw it down. Doesn't get any easier than that.
Was this helpful?
Thank you for voting!
No water through door dispenser
2 of 3 people found this instruction helpful.
  • Roger from Colleyville, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Ama zing.
Was this helpful?
Thank you for voting!
The freezer light shield was broken.
2 of 3 people found this instruction helpful.
  • Fred from Union, NJ
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I removed the ice maker,removed the broken piece of the old light shield,screwed the new light shield in place,and replaced the ice maker.It took all of 5 minutes.
Was this helpful?
Thank you for voting!
frost/ice buildup in icemaker chute in the freezer door
2 of 3 people found this instruction helpful.
  • Kyoko from Bellevue, WA
  • Easy
  • 30 - 60 mins
  • Screw drivers
The only difficult part was not knowing which parts had to be removed to gain access to the flapper to replace it. It appeared as if the frame around the control panel would have to be removed as well as the door handle; we tried but were not able to remove the frame. It turned out that the panel just popped out with the frame in place. O nce we had access to the flapper, it was easy to replace it. The repair fixed the problem.
Was this helpful?
Thank you for voting!
Flapper was worn and misshapen allowing warm air in freezer, ice cubes to melt and drip and impairing function of ice dispenser. Frost formed in ice dispensing chute also.
1 person found this instruction helpful.
  • Mark from HAYMARKET, VA
  • Easy
  • 15 - 30 mins
  • Screw drivers
Followed the online video. Unplugged refrigerator, removed trim piece, lifted control board cover, removed 4 screws retaining circuit control board and removed the 3 connectors from the control board. Located flapper and removed by using small flat tip to take tension off flapper connectors. Helper held flash light to illuminate flappe r connectors. Reversed procedure. New flapper seals well and cured problems. Circuit board was a bit different than one in video, but still had the 3 connectors. Marked each connector with grease pencil at top edge to ensure correct reconnection. Should note how wires are threaded around circuit board to ensure they are tucked back in correctly in reassembly. Remove trim piece carefully. I broke 2 of the 8 plastic pins that hold trim on. May be due to age of unit as they were brittle. 6 pins still hold trim piece flush.
Was this helpful?
Thank you for voting!
Original part cracked allowing crushing fingers to grab plastic guide jamming it.
1 person found this instruction helpful.
  • Barry from SUN VALLEY, CA
  • Really Easy
  • 30 - 60 mins
  • Screw drivers, Socket set
Part attaches to metal plate near crushing fingers which attaches to ice holding bin. Remove about 6 screws total on each side of plate. You must disassemble the auger & other parts so you can reassemble it in the proper order. Not many parts but i always take pics to cut down on time. New part is at the other end of the auger and acts a s the holde of the auger shaft. Picture a crankshaft with a bearing on each end so the auger rotates between new part and the other end of auger shaft. That's it.
Was this helpful?
Thank you for voting!
Warm air enters ice dispenser on door
1 person found this instruction helpful.
  • J Stephen from BETHESDA, MD
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
Replaced flapper. Followed the video. The lamp caused the removable plastic bracket (which supports the control panel and the ice chute) to fuse with the plastic frame in the door. Eventually broke the fused plastic, removed the bracket, and filed the rough broken plastic before reassembly.
Was this helpful?
Thank you for voting!
On the water dispenser line, the heat from the compressor unit had cracked the feed line, resulting in a leak.
1 person found this instruction helpful.
  • Walter from SANDIA PARK, NM
  • Really Easy
  • 30 - 60 mins
  • Nutdriver
I removed the plate covering the water valve for the ice maker and water dispenser, removed the nut holding the 5/16" tubing to the valve and took off the tubing and nut. I did not need to turn off the water supply or unplug the unit. I removed the kick panel in the bottom front of the refrigerator, replaced the existing plastic fitting w ith a new push-on fitting, then spliced the tubing coming from the water chiller to the valve where the leak was thus bypassing the broken tubing with new tubing. I reassembled the valve using the original plastic compression nut, replaced the cover and ran the water dispenser while checking for leaks. The water dispanser works great with no leaks.
Was this helpful?
Thank you for voting!
Ice Crusher began to leave plastic in ice
1 person found this instruction helpful.
  • Richard from BONAIRE, GA
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Screw drivers
We only needed the rear plastic cylindrical helix. After installing it, there was a squeal of metal on metal due to insufficient clearance between the rear moving blade and the Ice dispenser plate.

Refrigerator Ice Maker 7/16” (or ½” hole, stainless steel) washer just behind #334 Rear Moving dispenser Blade PS292310 to give clearance so it doesn’t hit #345 / PS292441 Ice Dispenser Plate.

This was my first time at doing this so it took longer than someone experienced. But, it worked!
Was this helpful?
Thank you for voting!
Remove front cover
1 person found this instruction helpful.
  • Philip from S BURLINGTON, VT
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
Remove front cover did not remove wires remove ice and water unit took off flapper put new one on 5 minutes back together
Was this helpful?
Thank you for voting!