my refigerator was warm but the freezer was cold and working correcttly
304 of 403 people found this instruction helpful.
  • michele from North Smithfield, RI
  • Really Easy
  • 15 - 30 mins
  • Pliers
I went to a GE repair center to explain my problem, the service center reccomended that I have a techinician come out o look at it. $75.00 for the visit and what ever labor and materials wuld cost.

I went on line to see if there were others having this same problem and found that there were many with the same problem.
... Read more />After reading some of the ways that people found out what was wrong ...it became a matter of three components, the timer, heater or thermostat.

I tried the most common component and the less expensive one first , the thermostat switch I installed it very easily snipping two wires and attaching the news using wire nuts I used the diagram on this website to pinpoint the component and there has not been a problem since.
Was this helpful?
Thank you for voting!
refrigerator was getting too cold
149 of 218 people found this instruction helpful.
  • Larry from Menomonie, WI
  • A Bit Difficult
  • 15 - 30 mins
I removed the old temperature sensor by cutting the wires. I attached the wires of the new sensor with wire nuts and mounted it in the same bracket.
Was this helpful?
Thank you for voting!
fridge side freezes some items
55 of 77 people found this instruction helpful.
  • Anthony from Murfreesboro, TN
  • Really Easy
  • Less than 15 mins
  • Screw drivers
went to your website and viewed exploded view to find the sensor( there are two I just picked one to replace for now), pried the cover off carfully and pulled out the sensor. I snipped the wire in the middle leaving plenty to work with. I shortened the wire on the new piece, spliced the wires together and with some 3M rubberized, tape wr apped them up, replaced the sensor back into the cover and snapped in place.
Was this helpful?
Thank you for voting!
freezer cold / fridge warm
46 of 54 people found this instruction helpful.
  • Mark from Mancos, CO
  • Easy
  • 30 - 60 mins
  • Screw drivers
put fridge into test mode, failed One sensor. Took it out, Tested it, Ordered part also picked up splice kit from electric store spliced it truned on and good to go
Was this helpful?
Thank you for voting!
Freezer would not defrost correctly
32 of 34 people found this instruction helpful.
  • Michael from Milton, FL
  • Really Easy
  • Less than 15 mins
  • Pliers
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
Was this helpful?
Thank you for voting!
Ice & Ice Cream would melt and refreeze
30 of 34 people found this instruction helpful.
  • Joe from Suffolk, VA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Was this helpful?
Thank you for voting!
Freezer and fresh food section getting warm due to inside coils frosting over.
23 of 29 people found this instruction helpful.
  • John from Windham, NH
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Screw drivers, Socket set
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged r efridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
Was this helpful?
Thank you for voting!
change water filter
29 of 65 people found this instruction helpful.
  • Cesar from ROYAL PLM BCH, FL
  • Really Easy
  • Less than 15 mins
un twist old one and twist the new one
Was this helpful?
Thank you for voting!
refrigerator and freezer stopped working
9 of 9 people found this instruction helpful.
  • mike from Aguilar, CO
  • Really Easy
  • 30 - 60 mins
  • Nutdriver
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
Was this helpful?
Thank you for voting!
Defrost not working coil iced up
3 of 3 people found this instruction helpful.
  • charles from SCOTTSDALE, AZ
  • Very Easy
  • 30 - 60 mins
  • Nutdriver
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard w as replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
Was this helpful?
Thank you for voting!
refriderator not cooling consistetly
4 of 6 people found this instruction helpful.
  • randall from coopersville, MI
  • Easy
  • Less than 15 mins
  • Pliers, Screw drivers
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
Was this helpful?
Thank you for voting!
condenser icing refrigerator warm freezer ok
3 of 4 people found this instruction helpful.
  • Rene from HEBER, CA
  • Really Easy
  • 30 - 60 mins
  • Pliers
follow the easy instructions replace 3 temperature sensors cut the wires and crimp them with new sensor and it works like new
Was this helpful?
Thank you for voting!
both freezer and refigerator were warm.
2 of 2 people found this instruction helpful.
  • Harry from DURYEA, PA
  • Easy
  • 15 - 30 mins
  • Nutdriver
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
Was this helpful?
Thank you for voting!
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
2 of 3 people found this instruction helpful.
  • Mark from ROSEMOUNT, MN
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of f reezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Was this helpful?
Thank you for voting!
Refrigerator not getting cold
1 person found this instruction helpful.
  • Dan from COLUMBIA, SC
  • Really Easy
  • 15 - 30 mins
  • Pliers, Socket set
Replaced Temperature Sensor and now it is getting cold.