My light always stayed on and the icemaker stopped working.
2 of 2 people
found this instruction helpful.
-
Jeremy from BYRON, MN
- Really Easy
- 15 - 30 mins
-
Nutdriver
I diagnosed the sensors in my refrigerator by holding the sensor in and seeing if I could trick the sensor it partially worked. I then used a multimeter and did an ohm test on both sensors multiple times open and closed the switch to verify which switch failed because it worked a couple times but not always. It ended up being the switch
... Read more
on the left hand door with 3 terminals on it and after the replacement it has worked great for weeks now no issue. best 15 dollars and 25 minutes spent!
Read less
Was this helpful?
Thank you for voting!
broken door shelf
2 of 2 people
found this instruction helpful.
-
James from SUN LAKES, AZ
- Really Easy
- Less than 15 mins
It snapped in place.
Was this helpful?
Thank you for voting!
Shelf on right Door Broke - Fell apart
2 of 2 people
found this instruction helpful.
-
James from OAK FOREST, IL
- Really Easy
- Less than 15 mins
Once I received that New Part, just place the 1 Piece from the old Shelf into the New Part and mounted the Shelf in the Door.
Was this helpful?
Thank you for voting!
Compressor would run for three seconds and stop, two minutes and repeat.
2 of 2 people
found this instruction helpful.
-
Steve from SPRINGFIELD, SC
- Really Easy
- Less than 15 mins
-
Nutdriver
The overload protector was the problem. It plugs into the side of the compressor and the run capacitor plugs into it.
If you pull the overload protector and it rattles when you shake it, that's probably your diagnosis.
The replacement is different from the original and the wire connectors are different. Hold the thin ... Read more g in the same orientation as if it were plugged in. The vertical connector goes to the neutral wire, which on my fridge is orange. The horizontal connector is for the overload, which for mine is black and white. If you have a schematic you should verify the wires yourself.
Anyway, the refrigerator now works like new.
If you pull the overload protector and it rattles when you shake it, that's probably your diagnosis.
The replacement is different from the original and the wire connectors are different. Hold the thin ... Read more g in the same orientation as if it were plugged in. The vertical connector goes to the neutral wire, which on my fridge is orange. The horizontal connector is for the overload, which for mine is black and white. If you have a schematic you should verify the wires yourself.
Anyway, the refrigerator now works like new.
Read less
Was this helpful?
Thank you for voting!
Lights in the refrigerator were very dim
3 of 5 people
found this instruction helpful.
-
Elias from PARKER, CO
- Really Easy
- Less than 15 mins
I determined one of the five LED lights in the refrigerator was dead by swapping it with a working one. The refrigerator lights are wired in series and if one of the lights is dead the remaining ones turn on, but very dim. I called PartSelect.com and thanks to their help we determined the correct part to order which is the oval-shaped cov
... Read more
er LED assembly which includes the cover, LED, and female connector. The part from PartSelect arrived in three days. The oval-shape LED plastic Cover assembly is mounted on the refrigerator and held by a couple of side latches. First unplug the refrigerator and then proceed to lightly pry the oval-shaped cover side facing the rear of the refrigerator with your finger nail to remove it. With the LED cover removed you can then press on the LED connector tab to slide it off. Now slide the female connector of the replacement part to the refrigerator male connector and snap the oval-shape plastic cover onto the refrigerator receptacle and then plug it back to its outlet. Now all the lights in the refrigerator should light up brightly! That's all folks. Hope this helps. Good luck. Yours truly.
Read less
Was this helpful?
Thank you for voting!
COVER LATCH BROKEN
2 of 3 people
found this instruction helpful.
-
Steven from NORMAN, OK
- Really Easy
- 30 - 60 mins
I recieved the package with the correct part number but the wrong part inside. The item in the package does not even resemble the part on the GE parts website. Tried to contact parts select but no luck.
Other Parts Used:
Was this helpful?
Thank you for voting!
left glide was broken
1 person
found this instruction helpful.
-
Michael from JACKSONVILLE, FL
- Very Easy
- 30 - 60 mins
-
Socket set
Left side was broken for about 8 years. Back of glide would fall down about every 4 months. This time the upper basket jammed up on the glide and the freezer drawer would not close. Had to break it to remove the upper basket.
From the time the parts were delivered and installed two Glide Supports, it took a total of 30 minutes. ... Read more If that long. Before I ordered the part, I made sure I had the socket to fit the nut and that I was able to remove it. I removed the broken one after ordering.
PartSelect was the only website that I could find that carried the part.
From the time the parts were delivered and installed two Glide Supports, it took a total of 30 minutes. ... Read more If that long. Before I ordered the part, I made sure I had the socket to fit the nut and that I was able to remove it. I removed the broken one after ordering.
PartSelect was the only website that I could find that carried the part.
Read less
Was this helpful?
Thank you for voting!
Replaced thermistor 5.2 ohms of resistance
2 of 4 people
found this instruction helpful.
-
elissa from ASHBY, MA
- Very Easy
- More than 2 hours
Exposed evap defrosted with heat gun exposed defrost element defrost termination switch ok therminster didn’t check out the thermistor sends the signal to logic panel then run the the freezer ice machine and refer temps it took 24 hours before the system starting to show results freezer compartment 10 below ice compartment 0 degrees refer
... Read more
temp 37 degrees one refrigerant three different temps system is running at optimum performance 450.00 $ service call the thing with GE appliances there is no wiring diagram .thankyou parts select .ill use you on all domestic service calls.
Read less
Was this helpful?
Thank you for voting!
Replace butter compartment on GE Profile
1 person
found this instruction helpful.
-
Gary from LAKE PLACID, NY
- Very Easy
- Less than 15 mins
It just snapped in. Fit perfectly. Excellent service.
Was this helpful?
Thank you for voting!
The Freezer has a slide out shelf. It kept coming off the glide support and the support actually broke!
1 person
found this instruction helpful.
-
Matthew from ROCKVILLE, MD
- Really Easy
- Less than 15 mins
-
Socket set
I looked online and it said GE does not make the support for my model Refrigerator/freezer. I looked the picture for this part and it looked like the same one so I bought it (very inexpensive) and an extra one just in case.
I took out most of the items on that sliding shelf and pulled it out. Found the correct socket for the nut an ... Read more d removed the remaining piece. Then just used the same nuts and new Glide support, tightened it up (but not too much, and tried the shelf.
It worked !!! I added the frozen foods and I was done. It was very fast. And by the way, I am not a big home repair person. EASY.
I took out most of the items on that sliding shelf and pulled it out. Found the correct socket for the nut an ... Read more d removed the remaining piece. Then just used the same nuts and new Glide support, tightened it up (but not too much, and tried the shelf.
It worked !!! I added the frozen foods and I was done. It was very fast. And by the way, I am not a big home repair person. EASY.
Read less
Was this helpful?
Thank you for voting!
I dropped The top left bin and it cracked
1 person
found this instruction helpful.
-
Karen from Salisbury, NC
- Very Easy
- Less than 15 mins
Popped it up and popped new one on
Was this helpful?
Thank you for voting!
The control board generated clicking noise. Temperature display wrong values.
1 of 2 people
found this instruction helpful.
-
QUOC-LOC from LYNN HAVEN, FL
- Really Easy
- 30 - 60 mins
-
Screw drivers
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
P ... Read more lugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
P ... Read more lugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
Read less
Was this helpful?
Thank you for voting!
Water filter needed changing.
0 of 1 people
found this instruction helpful.
-
Sara from White Plains, NY
- A Bit Difficult
- 15 - 30 mins
Snap filter into place while holding the filter slightly away from the refrig. When filter snaps into place, push it towards refrig into place.
Was this helpful?
Thank you for voting!
compressor motor wouldn't start, so no refrigeration
-
William from Pasco, WA
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Pliers
My brother-in-law is a 15 year refrigeration technician who I called and described the problem to. He told me to put an "amp clamp" on the line side of the wires (black) that go to the starting controls on the side of the compressor. The motor has a label that has a number on it (LRA) that he used to determine the max amps it would pull.
... Read more
In this case, if the motor pulled 10 amps, then the motor was bad and I'd have to buy a new refrigerator. It was pulling less then 9 amps so he thought to buy a new overload, since the capacitor checked out (measured by multi-meter). As soon as the part came, I removed the back panel (4 screws removed by nut driver), removed the clip that holds the overload/capacitor assembly, detached the two wires from it, and removed the capacitor from the overload. I swapped in the new overload and repeated the above process in reverse. The only difficulty was that the new part was different in that the plug-in locations for the two wires were in different locations, and not marked. I had to disassemble the old part to figure out how it worked so I could deduce how the new one plugged in. Once that was solved, it was a quick fix. This was not a repair that just anyone could do; it required someone with a lot of experience to help me, and I am an engineer.
Read less
Was this helpful?
Thank you for voting!
Freezer And Frig Both Warm And Compressor Would Not Run
-
joe from decatur, GA
- Easy
- 15 - 30 mins
-
Screw drivers, Wrench (Adjustable)
I replaced the thermostat, temperature sensor, and the run capacitor. . . Refrigerator still not cooling. I checked the start relay and measured the input terminals on the compressor for the correct resistance. . . Everything measured correctly. In a last ditch effort before calling for service, I pulled the main board, inspected it and
... Read more
saw the problem right away. One leg on the compression capacitor had desoldered itself. Got out my soldering iron and applied a good amount of solder to that point. Put everything back together and turn it on. . . Problem fixed. The compressor kicked on right away and started cooling the refrigerator.
Read less
Was this helpful?
Thank you for voting!