ice maker was leaking water
13 of 22 people found this instruction helpful.
  • Sandra from Temecula, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Parts went right into place as the pictures showed and was working again in about 30 minutes. The only thing that wasn't working was the ice took forever to make, but solved that problem by turning up the temp in the freezer.
Was this helpful?
Thank you for voting!
THERMOSTAT
9 of 10 people found this instruction helpful.
  • dominique from COMPTON, CA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
I followed your instructions , the only thing that was left out was that the freezer has a drain hole that had to be thawed out with a hair dryer,till the water went to the drain pan underneath the ref. your instruction were through enough, that's why I purchased the part from your company, I installed the part 2 days ago and its working like new again 23.00 for the part instead of 1200.00 dollars for another ref. thanks very much. 6 months ago I purchased the relay and compressor starter from your company at that time per your instructions I shook the compressor starter and like a light bulb it had something broke inside,I needed that thanks again oomk
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people found this instruction helpful.
  • JAMES from Middleboro, MA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Was this helpful?
Thank you for voting!
Ice maker motor would run continuously but the blades would not turn and no ice came out.
9 of 11 people found this instruction helpful.
  • Gary from Medway, MA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I wasn't sure what the problem was, but the ice maker seemed simple and on-line resources suggested the control and motor assemblty was at fault. I searched the internet and Partsource had great diagrams which I could match to the part in hand. The price was right (way less than the local stores) so I ordered it.
I unplugged the unit from the power in the freezer, but unplugging the entire refrigerator works too. I pried off the white cover on the front of the ice maker, which snaps in place top and bottom. There are three screws holding the contoller (the entire front piece), remove them, pull off the controller and push the new one in place. You may have to turn the blade shaft to line up the notch on the shaft to the motor. Then reinstall the three screws, The screws go into plastic so it is easy to cross thread them, so be careful, I actually think I did with no ill effects. Snap on the cover and repower the unit. Done. Simple and quick.
Was this helpful?
Thank you for voting!
the food portion of the fridge was warm
8 of 8 people found this instruction helpful.
  • Raymond from Plymouth, MA
  • Easy
  • 15 - 30 mins
  • Screw drivers
I turned off the electricity, then removed only on screw then lowered the casing that holds the trmp control knobs. The casing hung in place by the wires and I just replaced the the thermostat by holding next to the original and put the 3 wires in the same location. Then unrolled the wire connected to the sensor and put in place of the ol d one. It was very easy. I had read a previous repair story that said that the food area froze - the same thing happened to me, then it was normal, then no cooling, so I tried this part and it has worked very well, and real easy to do.
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people found this instruction helpful.
  • George from Glenwood, MN
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Was this helpful?
Thank you for voting!
didn't eject icecubes
9 of 12 people found this instruction helpful.
  • Ronald from Marion, IL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin
Was this helpful?
Thank you for voting!
Ice maker leaked water
10 of 15 people found this instruction helpful.
  • Robert from Pennsylvania Furnace, PA
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers, Socket set
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.
Was this helpful?
Thank you for voting!
replacing thermostat did not help
10 of 15 people found this instruction helpful.
  • John from Rocky River, OH
  • Difficult
  • More than 2 hours
  • Pliers, Screw drivers, Socket set
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiv er boaed. I turn off manually the icemaker, when needed
Was this helpful?
Thank you for voting!
35 year old water tube became brittle and cracked; leaking water
8 of 10 people found this instruction helpful.
  • Melvin from OPELIKA, AL
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Was this helpful?
Thank you for voting!
shelf bar end caps broke
7 of 7 people found this instruction helpful.
  • Donald from Taneytown, MD
  • Really Easy
  • Less than 15 mins
slid new end caps onto bar and snaped back in to door. It took less than 1 minute.
Was this helpful?
Thank you for voting!
Ice getting stuck, and water flowing over everything
7 of 7 people found this instruction helpful.
  • Randal from Wakefield, RI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
The on-line video and the hard-copy instructions with the replacement part made it very easy. Just loosened the 2 upper screws and took out the bottom one. Eased the ice maker out a bit and disconnected the plug at the back (power was off). Checked the replacement part had exactly the same wiring harness - it did. Fitted the bail arm from the old one. So simply did the same process in reverse. So 15-20 minutes after I started, the job was compelete. It takes a while for ice to start coming, but it did, and after 24 hours I threw out the ice and started again to make sure the ice came from fresh water.
Was this helpful?
Thank you for voting!
Ice maker leaked into ice reservoir
7 of 7 people found this instruction helpful.
  • joe from hilliard, OH
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
The ice mold has a coating on it. Over time the coating deteriorates. If your ice maker leaks water into the ice reservoir inspect the mold to see if the coating is compromised. If so, replace with new.

Remove the ice maker assembly. 3 small hex screws. Unplug power cord. Disassemble ice maker assembly. Remove ice mold/h eater. Replace with new. Reassemble.
Was this helpful?
Thank you for voting!
food inside non freezer part of the refrigerator froze. Adjusting the temperature dials had no effect. Inside temp stayed in the 20s
8 of 10 people found this instruction helpful.
  • Carolyn from Lexington, SC
  • Easy
  • 15 - 30 mins
  • Screw drivers
First, we have to say that PartSelect web site was tremendously helpful. We had misplaced our refrigerator manual. PartSelect's troubleshooting advice helped us target the problem right away, we could see what the part number was and how much it would cost. It was then up to us to locate that part in the refrigerator and figure out how to get it out. Since it is located above the highest shelf, a mirror was required to see what it would take to remove the protective cage. We didn't know if it would snap out, slide out, or fall out once the screws were removed. To get the screws out required the body to twist around and look upward. Once the screws were removed, the cage dangled down by its wiring. The power was then turned off. The part was fitted into place quickly. We have to compliment PartSelect for the informative website and for swift delivery of our order.
Was this helpful?
Thank you for voting!
The Freezer defrosted and everything on the top and the bottom spoiled
10 of 16 people found this instruction helpful.
  • Jorge from Miami, FL
  • Easy
  • 15 - 30 mins
  • Nutdriver
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burn ed. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Was this helpful?
Thank you for voting!
All Instructions for the ATF1