The leak limiter or natural gas limiter is used in dryers. This part acts as a cover of the adjustment screw on the pressure regulator. If you are changing from propane (LP) back to natural gas, it is best to replace this part. To convert your washer from LP to natural gas, remove the top of the dryer and screws to access the computer. Wh
...Read moreen control panel is accessed, remove the wire harnesses in the front and the control panel itself. Next, remove the access panel and disconnect the wire that activates the moisture sensor. Remove the main front panel using a 1/4 inch nut driver and the belt from the pulley. Once you pull out the drummer you now have access to the gas valve. Refer to the diagram for further installation instructions. Remember to unplug your dryer from the power source for safety.
Read less