ASNW2 LG Air Conditioner - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Motor Assembly, DC, Stepping had quit working which caused the loover on the front of the air conditioner to remain open
6 of 10 people
found this instruction helpful.
-
DOUG from SHERIDAN, WY
- A Bit Difficult
- 1- 2 hours
-
Screw drivers
Main problem was removing the cowling from the LG head unit as I had no instructions on how to do it. I had watched the previous technicians that had worked on the unit remove it. Once the cowling is removed all that needs done is remove the 2 mounting screws and unplug the old motor, plug in the new motor and remount it with the 2 screws
... Read more
. Then the cowling has to be reinstalled.
Read less
Was this helpful?
Thank you for voting!
Error display indicated a bad Thermistor
-
Ken from Endicott, NY
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
Ordered replacement part from Part Select. Part verified thru LG customer service. LG stated that connector on Part Select Thermistor assembly won't match the connector in the LG unit. Cut the connector from the defective Thermistor and spliced it into the Thermistor from Part Select. Unit works fine after repair.
Was this helpful?
Thank you for voting!