Ice Bin Enclosure Cracked
12 of 14 people
found this instruction helpful.
-
George from Reeds Spring, MO
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
As the previous users have stated, remove the ice tray, then remove the ice bin enclosure. Watch for the screws that are used to mount the enclosure.
As you slide the enclosure forward, go slowly, there is a wiring connector at the back, you will need to un-plug this connector. The solenoid assy is kind of tricky, as it is spring loa ... Read more ded, but easy to figure out. As previously mentioned, the auger yoke is on a shaft that has to be removed by turning it clockwise (reverse threads). Be careful with that, as it is hard to hold on to the shaft while getting the yoke off. Now remount the motor, remount the spring loaded solenoid assy, slide the ice bin enclosure back in a ways, then reconnect the wiring harness, slide it the rest of the way in, tighten the screws, and you are ready to make ice again. Approx 30 minute job.
As you slide the enclosure forward, go slowly, there is a wiring connector at the back, you will need to un-plug this connector. The solenoid assy is kind of tricky, as it is spring loa ... Read more ded, but easy to figure out. As previously mentioned, the auger yoke is on a shaft that has to be removed by turning it clockwise (reverse threads). Be careful with that, as it is hard to hold on to the shaft while getting the yoke off. Now remount the motor, remount the spring loaded solenoid assy, slide the ice bin enclosure back in a ways, then reconnect the wiring harness, slide it the rest of the way in, tighten the screws, and you are ready to make ice again. Approx 30 minute job.
Read less
Was this helpful?
Thank you for voting!
No water to icemaker
11 of 12 people
found this instruction helpful.
-
Philip from Mission Viejo, CA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Wrench (Adjustable)
Easy to diagnose problem because there was water to the water dispenser but none to the newly installed icemaker. Originally did attempt to clean the solenoid but found the plunger assembly damaged.
New part arrived sooner than I thought it would. Takes about as much time to remove the lower vent cover as to replace the valve ... Read more . Remove the electrical plug from the wall, valve off the main water supply, remove lower vent cover, disconnect the supply hose from refrigerator valve assembly, remove one hex head mounting screw and you have both water valves in your hands. Identify the valve the supplies water to the filter and the one that supplies water to the icemaker/water dispenser. Then confirm which plastic water supply line goes to the water dispenser and which goes to the icemaker. Hose diameters are different but it is good to know. Disconnect the plastic water supply lines from both the ice dispenser and the icemaker portions of the valve. Replacement solenoid valve does not have thread on type compression fittings. Snip about an inch off of each hose and then press into the appropriate valve orifice.
Making sure the plastic supply lines do not get crimped, remount the valve assembly, reattach the supply hose, valve on the water and check for leaks. No leaks, reinstall dust cover and plug the refrigerator back in.
Move the unit back in place and then take a long deserved beer out and have a celebratory toast for a job well done.
New part arrived sooner than I thought it would. Takes about as much time to remove the lower vent cover as to replace the valve ... Read more . Remove the electrical plug from the wall, valve off the main water supply, remove lower vent cover, disconnect the supply hose from refrigerator valve assembly, remove one hex head mounting screw and you have both water valves in your hands. Identify the valve the supplies water to the filter and the one that supplies water to the icemaker/water dispenser. Then confirm which plastic water supply line goes to the water dispenser and which goes to the icemaker. Hose diameters are different but it is good to know. Disconnect the plastic water supply lines from both the ice dispenser and the icemaker portions of the valve. Replacement solenoid valve does not have thread on type compression fittings. Snip about an inch off of each hose and then press into the appropriate valve orifice.
Making sure the plastic supply lines do not get crimped, remount the valve assembly, reattach the supply hose, valve on the water and check for leaks. No leaks, reinstall dust cover and plug the refrigerator back in.
Move the unit back in place and then take a long deserved beer out and have a celebratory toast for a job well done.
Read less
Was this helpful?
Thank you for voting!
noisy fan motor, fridge & freezer not holding temp
13 of 18 people
found this instruction helpful.
-
Paul from Joshua Tree, CA
- Difficult
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
I took off the ice maker, disconected the wiring, took out the back of the freezer and took out the fan motor. Harder than I thought because of all the wiring back there, light, fan assembly etc. After that it was easy, took out the old motor & installed the new one. Runs much quieter now, and the fridge & freezer are much colder.
I ... Read more did this for less than the price of a service call by a repair shop.
I ... Read more did this for less than the price of a service call by a repair shop.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Ice Maker selnoid malfunctioned.
11 of 13 people
found this instruction helpful.
-
Robert from Kokomo, IN
- Really Easy
- 15 - 30 mins
-
Pliers, Screw drivers
I called PartSelect and was greeted by a real live person instead of a recording. The lady was very helpful and kind. We decided on the part that I needed, and it arrived to my home in less time than she said it should. I completed the repair with the instructions provided in just a short time. My experience with PartSelect was positive,
... Read more
and it reminded me of the way businesses used to be. I highly recommend them.
Read less
Was this helpful?
Thank you for voting!
Refrigerator Ice Maker stopped making ice.
18 of 34 people
found this instruction helpful.
-
Harold from Oakton, VA
- Really Easy
- 15 - 30 mins
-
Nutdriver
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from
... Read more
the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!
Read less
Was this helpful?
Thank you for voting!
the ice/water actuator switch burnt out and was stuck on.
11 of 13 people
found this instruction helpful.
-
Jon from Nampa, ID
- Easy
- 15 - 30 mins
-
Screw drivers
Removed the rubber cover over the actuator switch. Used a screwdriver to remove the switch, disconnected the wires. I then removed the switch from the mounting bracket using a small philips head screw driver. Installed the new switch on the mounting bracket then installed the switch onto the freezer door. The only difficult part was
... Read more
installing the rubber cover. Now I just need to repair the damage to my hardwood floors and carpet from all the water.
Read less
Was this helpful?
Thank you for voting!
Fridge stopped working
10 of 11 people
found this instruction helpful.
-
Dan from Sumner, WA
- Easy
- 15 - 30 mins
-
Nutdriver
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98.
So I used wha ... Read more t he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.
So I used wha ... Read more t he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.
Read less
Was this helpful?
Thank you for voting!
Leaking water tube connector/union
10 of 12 people
found this instruction helpful.
-
Roderick from NEWTOWN, PA
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
Received the union I ordered, then discovered that the tubes were different sizes, so I had the wrong part. I had read elsewhere that it was necessary to trim the two ends of the tubes with a box cutter to stop the leaks - I did this, and the leaking stopped. I was then able to go to a local hardware store and get a 5/16 to 1/4 union and
... Read more
replace it. The leaking is stopped, and the water supply in the door is now working like new. No problem with partselect, but I did buy a caliper so that I can check tube diameters if I ever have a similar problem! This is a great site to find instructions - well worth the time to search!
Read less
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people
found this instruction helpful.
-
Steven from Brigham City, UT
- Really Easy
- 15 - 30 mins
-
Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Read less
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people
found this instruction helpful.
-
Benjamin from Daytona Beach, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
Read less
Was this helpful?
Thank you for voting!
Ice bucket auger yoke was stripped out and turned freely
9 of 9 people
found this instruction helpful.
-
James from Pineville, LA
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
Removed the ice bucket from the freezer. Removed the single screw on the left side with a nut driver, then lift and pull the tray toward you...there is a wiring harness in back of the tray that I had to unplug...easy, pinch the sides of the plastic connector and it disconnects..and the tray came out of the refrigerator...and the cussing s
... Read more
tarted. Since the threaded yoke was stripped it could not be unscrewed from the motor shaft...I took my trusty Dremel Tool and cut the shaft off so the yoke could be separated from the motor shaft and the motor could be removed from the plastic housing. From here on it was a piece of cake...install the new motor and screw the new yoke onto the motor shaft... I think it has a left handed thread, like the old propane bottles used to have..slide the tray back in, reconnect the wiring harness (it only plugs in one way), make sure the tray is sitting on the 4 side supports, put the single screw on the left side and you are done....put the ice bucket back in and flip the bail down and you should be back on business....!!
Read less
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people
found this instruction helpful.
-
Lori from Chuluota, FL
- Easy
- Less than 15 mins
-
Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people
found this instruction helpful.
-
JAMES from Middleboro, MA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Read less
Was this helpful?
Thank you for voting!
broken light switch
12 of 20 people
found this instruction helpful.
-
Richard from West Warwick, RI
- Really Easy
- Less than 15 mins
-
Screw drivers
followed the instructions provided and that's it!
Was this helpful?
Thank you for voting!
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
10 of 14 people
found this instruction helpful.
-
Kenneth from Newton Grove, NC
- Really Easy
- Less than 15 mins
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
Was this helpful?
Thank you for voting!