Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
14 of 16 people found this instruction helpful.
  • David from Cedarville, OH
  • A Bit Difficult
  • More than 2 hours
  • Screw drivers, Socket set
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Was this helpful?
Thank you for voting!
light inside fridge was flickering and clicking
20 of 35 people found this instruction helpful.
  • bill from escondido, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Was this helpful?
Thank you for voting!
Broken cup water fill on ice maker
13 of 15 people found this instruction helpful.
  • Matthew from Aurora, CO
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.

Thanks,
Matt
Was this helpful?
Thank you for voting!
Light switch in freezer side got broken
12 of 12 people found this instruction helpful.
  • Doug from PLEASANT VIEW, TN
  • Really Easy
  • Less than 15 mins
Took a putty knife and
Removed the old switch removed the spade terminals from the old switch and replaced them on the new switch and just pushed the new switch back in place
Was this helpful?
Thank you for voting!
Ice maker over flowing
13 of 16 people found this instruction helpful.
  • ben from manhattan, KS
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
My ice maker was overflowing and i realized that it was the water valve that needed replaced. unscrewed 1 nut, unhooked 3 water lines, unhooked electrical components and re-installed in reverse order. took about 10-15 mins.
Was this helpful?
Thank you for voting!
Compressor not working
12 of 13 people found this instruction helpful.
  • Terry from Knoxville, TN
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Extremely easy install. Just popped off the cover located on the side of the compressor. Noted placement of the wires on the overload and relay. Took a small screwdriver to slide both from the electrical pins on the compressor...take care doing this. Unplugged the wires, plugged the new components to the wires and installed to the compres sor. Plugged in the frig and the compressor came on. Not sure why these went out to begin with but the fix was extremely easy and saved me the expense of a repair man.
Was this helpful?
Thank you for voting!
Ice Bin Enclosure Cracked
12 of 14 people found this instruction helpful.
  • George from Reeds Spring, MO
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
As the previous users have stated, remove the ice tray, then remove the ice bin enclosure. Watch for the screws that are used to mount the enclosure.
As you slide the enclosure forward, go slowly, there is a wiring connector at the back, you will need to un-plug this connector. The solenoid assy is kind of tricky, as it is spring loa ded, but easy to figure out. As previously mentioned, the auger yoke is on a shaft that has to be removed by turning it clockwise (reverse threads). Be careful with that, as it is hard to hold on to the shaft while getting the yoke off. Now remount the motor, remount the spring loaded solenoid assy, slide the ice bin enclosure back in a ways, then reconnect the wiring harness, slide it the rest of the way in, tighten the screws, and you are ready to make ice again. Approx 30 minute job.
Was this helpful?
Thank you for voting!
No water to icemaker
11 of 12 people found this instruction helpful.
  • Philip from Mission Viejo, CA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Wrench (Adjustable)
Easy to diagnose problem because there was water to the water dispenser but none to the newly installed icemaker. Originally did attempt to clean the solenoid but found the plunger assembly damaged.

New part arrived sooner than I thought it would. Takes about as much time to remove the lower vent cover as to replace the valve . Remove the electrical plug from the wall, valve off the main water supply, remove lower vent cover, disconnect the supply hose from refrigerator valve assembly, remove one hex head mounting screw and you have both water valves in your hands. Identify the valve the supplies water to the filter and the one that supplies water to the icemaker/water dispenser. Then confirm which plastic water supply line goes to the water dispenser and which goes to the icemaker. Hose diameters are different but it is good to know. Disconnect the plastic water supply lines from both the ice dispenser and the icemaker portions of the valve. Replacement solenoid valve does not have thread on type compression fittings. Snip about an inch off of each hose and then press into the appropriate valve orifice.

Making sure the plastic supply lines do not get crimped, remount the valve assembly, reattach the supply hose, valve on the water and check for leaks. No leaks, reinstall dust cover and plug the refrigerator back in.

Move the unit back in place and then take a long deserved beer out and have a celebratory toast for a job well done.
Was this helpful?
Thank you for voting!
noisy fan motor, fridge & freezer not holding temp
13 of 18 people found this instruction helpful.
  • Paul from Joshua Tree, CA
  • Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I took off the ice maker, disconected the wiring, took out the back of the freezer and took out the fan motor. Harder than I thought because of all the wiring back there, light, fan assembly etc. After that it was easy, took out the old motor & installed the new one. Runs much quieter now, and the fridge & freezer are much colder.
I did this for less than the price of a service call by a repair shop.
Was this helpful?
Thank you for voting!
Refrigerator Ice Maker stopped making ice.
18 of 34 people found this instruction helpful.
  • Harold from Oakton, VA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!
Was this helpful?
Thank you for voting!
Ice Maker selnoid malfunctioned.
11 of 13 people found this instruction helpful.
  • Robert from Kokomo, IN
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
I called PartSelect and was greeted by a real live person instead of a recording. The lady was very helpful and kind. We decided on the part that I needed, and it arrived to my home in less time than she said it should. I completed the repair with the instructions provided in just a short time. My experience with PartSelect was positive, and it reminded me of the way businesses used to be. I highly recommend them.
Was this helpful?
Thank you for voting!
the ice/water actuator switch burnt out and was stuck on.
11 of 13 people found this instruction helpful.
  • Jon from Nampa, ID
  • Easy
  • 15 - 30 mins
  • Screw drivers
Removed the rubber cover over the actuator switch. Used a screwdriver to remove the switch, disconnected the wires. I then removed the switch from the mounting bracket using a small philips head screw driver. Installed the new switch on the mounting bracket then installed the switch onto the freezer door. The only difficult part was installing the rubber cover. Now I just need to repair the damage to my hardwood floors and carpet from all the water.
Was this helpful?
Thank you for voting!
Fridge stopped working
10 of 11 people found this instruction helpful.
  • Dan from Sumner, WA
  • Easy
  • 15 - 30 mins
  • Nutdriver
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98.
So I used wha t he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.
Was this helpful?
Thank you for voting!
Door closer on refrigerator side was worn out
10 of 12 people found this instruction helpful.
  • Robert from Londonderry, NH
  • Really Easy
  • Less than 15 mins
  • Screw drivers, Socket set
This was a very simpler repair to an annoying problem. First I removed the decorative cover on the top hinge pin of the door which was held on with one screw. I then removed the 3 screws of the top hinge pin with a socket, held the door in place with my hand and took off the top pin. Next, I simply lifted the refrigerator door off the bottom worn out hinge.
removed the old door hinge bracket and bottom lower hinge pin that had worn, placed the new bottom hinge pin in the bracket. Finally, on the bottom of the refrigerator I replaced the natural door closer held on by one screw. Lifted the door back onto the new bottom hinge pin, held the door in place and installed the top hinge pin, put the cover back on and the refrigerator is closing like it was new again.
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people found this instruction helpful.
  • Steven from Brigham City, UT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.