No ice
8 of 13 people found this instruction helpful.
  • Jon from Boise, ID
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
1 screw remove assembly. Unplug cable harness and remove old cover and wire arm. Replace cover and wire arm and attach wire harness on assembly end. Re attach using screw removed in first step. Plug in wire harness. Making ice within 30 minutes.
Was this helpful?
Thank you for voting!
My icemaker started leaking water into the catch basin and turning my ice into one big ice burg.
6 of 7 people found this instruction helpful.
  • gary from carleton, MI
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Well folks I put up with an ice burg all summer when I really should have took the time to fix it. You know how it goes though. You get so busy you just put it off.
Well don't put this one off because this is just how easy it went.
I came home one evening and wanted to make a drink to relax but that big glob of ice was there w aiting for me. I took a crewdriver and beat it down so I could pull the catch basin out. Having looked it over for a minute I grabed a nut driver and took three of the screws out that held it in. I unpluged the wire and bingo it was out. Maybe five min. had elasped.
After taking the unit out I notice how the non stick surface was coming off of the tray and that explains the black pieces that were getting into my ice.
Getting the model number off the back of the fridge and writing it down I went to my trusty lap top and did a quick search for a ice maker for my Jenn Air refrigeraton and blamo...! Part Select came up and I put the part number in their search engine and bingo again there it was, my part.
One quick order and in three days it was right there by my door when I got home.
Now i'm so excited. I went into the house and didn't even chage out of my dress clothes. Within five minutes it was in. Now I just had to wait for the timer to do it's thing and sure enough, I awoke the next morning to a whole tray of beautiful ice cubes. Wow no more ice burgs.
The moral of my story is I spent so much time hacking out that glob of ice and for fifteen minutes of my time, I could have been siping on cold ones by the pool but now old man winter is pressing down on me and I guess a lesson learned was a lesson earned. Fix it!
Was this helpful?
Thank you for voting!
water leaked when the paddel was pushed
6 of 8 people found this instruction helpful.
  • Monica from EDMOND, OK
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Was this helpful?
Thank you for voting!
light bulb in water ice freezer door went bad
8 of 14 people found this instruction helpful.
  • Carl from RIVERSIDE, CA
  • Very Difficult
  • More than 2 hours
  • Screw drivers
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people found this instruction helpful.
  • Duncan from Metairie, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?
Thank you for voting!
Icemaker would not fill with water.
7 of 11 people found this instruction helpful.
  • Linford from Cedarville, NJ
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Removed screw under ice maker. Tilted ice maker up to remove unit from upper two screws. Disconnected plug at rear of freezer. Attached wiring harness, baler arm and cover from old to new ice maker. Reinstalled in reverse order. Had ice within one hour. Very easy fix.
Was this helpful?
Thank you for voting!
freezer was frosting up
7 of 11 people found this instruction helpful.
  • Daniel from Louisville, KY
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Follow your parts diagram, I removed the nut screw from the light in the refrigerator. Removed the light cover. Removed the temperture control knob. Remove the damper control cover. Slid the light assembly forward. Pulled out old defrost timer, replaced with new one. reversed assembly order.
Was this helpful?
Thank you for voting!
Refrigerator and freezer was not cooling. The compressor would not stay running. When the compressor kicked on it would only run for a few seconds and got warm real quickly. I replaced both the overload relay combination and the running capacitor. Don't know what the problem is. I thought for sure t
6 of 8 people found this instruction helpful.
  • Ronald from Monroe, WA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
disconnected wire connections, pulled old overload relay and running capacitor out like a plug and plug in the new one then reconnected the wires.
Was this helpful?
Thank you for voting!
Back of freezer froze up and not getting cold in refrigertor.
8 of 14 people found this instruction helpful.
  • Dustin from Piedmont, OK
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I got on the web blog and saw a conversation on here that sounded just like the problems i have been having with my unit. After reading every thing about it i ordered the part needed and installed it. I let the fridge thaw out over night and started it up the next morning. Its been two month since i installed the part and it is working g reat!!!
Was this helpful?
Thank you for voting!
Power cord was cut
6 of 8 people found this instruction helpful.
  • Frederick from Hanover, MA
  • Easy
  • 15 - 30 mins
  • Nutdriver
I removed the 5/16 inch hex head nuts holding the rear access panel where the power cord was connected. Once removed, I released the Molex plug and ground wire. I connected the new cord, screwed in the ground and installed the rear panel. Having the exact OEM part made the job quick and easy.
Was this helpful?
Thank you for voting!
My old icemaker lost some of the nonstick surface and the ice didn't want to come out
6 of 8 people found this instruction helpful.
  • Thomas from Ruth, MI
  • Easy
  • 15 - 30 mins
  • Screw drivers
I unhooked the wire harness from the ref. and took out three screws and pulled the old unit out. I than changed a few parts from the old icemaker to the new and reattached the new ice maker to the ref. and plugged the wire back in. everything is working fine. No problems. Also I was very happy with the ordering process. Thank you!!
Was this helpful?
Thank you for voting!
The ice maker stopped making ice.
5 of 5 people found this instruction helpful.
  • Thomas from Cupertino, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver
I did a few tests with the old ice maker and determined that it was the ice maker itself that was faulty. The replacement part I ordered exceeded my expectations in the time it took to get the part. I reused the arm, wire harness and clamps from the old icemaker. Then it was a simple install into the bottom freezer compartment, turning on the water supply and bingo...lots of ice cubes.
Was this helpful?
Thank you for voting!
refrigerator not cooling properly
6 of 9 people found this instruction helpful.
  • Ernie from Windsor, CA
  • Really Easy
  • 1- 2 hours
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Was this helpful?
Thank you for voting!
Thought motor was bad freezer cold fridge hot
4 of 4 people found this instruction helpful.
  • Wayne from PENNINGTON, NJ
  • Really Easy
  • 30 - 60 mins
Ordered new fan motor
Got part took fridge apart
Result was the motor was running
The fan blade had come off the motor
Replaced the motor anyway and reinstalled the fan, working well
Was this helpful?
Thank you for voting!
The water supply line to the ice maker kept popping off after I replaced the water filter because an "ice plug" had formed in the fill tube, unbeknownst to me.
5 of 7 people found this instruction helpful.
  • Michael from TAKOMA PARK, MD
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
1. Turn your water OFF and pull the refrigerator out from the wall so you can access the back.
2. Use pliers to remove tubing clamp.
3. Remove old water fill tube.
4. I used a putty knife to gently pry out the old fill tube from the back of the refrigerator. Once the fill tube pulls out about 1/4 to 1/2", then you ca n gently pull the remainder of the tube out by hand. Once I removed my "old" fill tube, that is when I saw the "ice plug" that was causing pressure in the water supply line and caused my water line to pop off.
5. Install new fill tube. The end that goes in first needs to go through a small "ring" inside the freezer (this "ring" is not encountered until the fill tube only has about one more inch to be inserted into the back of the refigerator. I could barely see this "ring" if I opened the freezer drawer and stuck my head in as far as I could. I had to gently rotate the new fill tube until it cleared the "ring". You will feel some resistance until it lines up properly.
6. Snugly push in the part that stays on the outside of the refrigerator until it looks like it is sealed.
7. Gently push up the water fill tube where it belongs in the new part and replace the tubing clamp.
8. Turn your water on and make sure there are no leaks (I left my refrigerator out for about an hour).
9. Push your refrigerator back in place.
Was this helpful?