Condenser fan motor seized
9 of 9 people found this instruction helpful.
  • Benjamin from Daytona Beach, FL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot al time of ice maker water leak repair and fan replacement about 1 hour.
Was this helpful?
Thank you for voting!
Defrost not working
11 of 15 people found this instruction helpful.
  • Glenn from Santa Rosa, CA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
There were three parts in question, the defrost timer (inside the casing near the control dial at the top of the refridgerator), the defrost thermostat (behind the back wall of the freezer), and the heater coil (ditto). We tested the defrost timer by opening it up, advancing it to the defrost cycle, and waiting for the compressor to star t up again, showing that the timer was working. Then we replaced the defrost thermostat and found that the heater coil worked.

The hardest part was figuring out how to open the casing and get to the timer. If I do it over again I will replace the $20 thermostat first and then deal with the timer if necessary. To get to the thermostat you can easily take the freezer door off by removing two screws in the door tracks. There was even an arrow pointing to one of the screws! Take out the food trays and then unscrew the back wall with a nut driver. The thermostat was clipped to one of the copper freezer tubes. I unplugged one end of the thermostat circuit at the lead to the heater coil and then cut the thermostat out of the circuit and used wire nuts to connect the new thermostat.
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people found this instruction helpful.
  • Lori from Chuluota, FL
  • Easy
  • Less than 15 mins
  • Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people found this instruction helpful.
  • JAMES from Middleboro, MA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Was this helpful?
Thank you for voting!
Breaks relatevely often when you accidently have either draws overloaded or open both of them at the same time
9 of 11 people found this instruction helpful.
  • Aggie from Prospect Hts, IL
  • Really Easy
  • Less than 15 mins
You need to lift up the glass part and simply fit it the center rail in, very simple
Was this helpful?
Thank you for voting!
broken light switch
12 of 20 people found this instruction helpful.
  • Richard from West Warwick, RI
  • Really Easy
  • Less than 15 mins
  • Screw drivers
followed the instructions provided and that's it!
Was this helpful?
Thank you for voting!
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
10 of 14 people found this instruction helpful.
  • Kenneth from Newton Grove, NC
  • Really Easy
  • Less than 15 mins
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people found this instruction helpful.
  • George from Glenwood, MN
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Was this helpful?
Thank you for voting!
didn't eject icecubes
9 of 12 people found this instruction helpful.
  • Ronald from Marion, IL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin
Was this helpful?
Thank you for voting!
Ice maker leaked water
10 of 15 people found this instruction helpful.
  • Robert from Pennsylvania Furnace, PA
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers, Socket set
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.
Was this helpful?
Thank you for voting!
Refrigerator wouldn't cool
10 of 15 people found this instruction helpful.
  • Fidel from Forest, MS
  • Easy
  • 30 - 60 mins
  • Screw drivers
First I removed the six screws from the cover. I then disconnected the two wires and pulled the small motor out with its base and removed two screws that hold it in place. I then changed the old one for the new one and set it back in its place. I then set the cover back and turned it on. I was happy again.
Was this helpful?
Thank you for voting!
35 year old water tube became brittle and cracked; leaking water
8 of 10 people found this instruction helpful.
  • Melvin from OPELIKA, AL
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Was this helpful?
Thank you for voting!
Ice Maker was not working
8 of 10 people found this instruction helpful.
  • Robert from Tampa, FL
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Based on other feedback, it sounded like a bad valve. I ordered it from Part Select and received it the next day. I am in NO WAY handy, but it took about 5 min to change using the instructions. Not bad considering I spent $33 on the part and I was quoted $280 by the authorized repair center.
Was this helpful?
Thank you for voting!
My son broke the door handle off the Refrigerator
13 of 25 people found this instruction helpful.
  • REBECCA from GREENFIELD TWP., PA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I removed two screws that were holding on broken handle. I put new handle in place and attached it with new screws. Ordering parts on line and receving them in mail a few days later was awsome. I did not need my husbands help at all .
Was this helpful?
Thank you for voting!
my freezer kept icing up and the light switch was broken
9 of 13 people found this instruction helpful.
  • Jacqueline from New London, CT
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I carefully took the clear plastic piece out of the top of the refrigerator. I removed two screws, unsnapped the white plastic cover and unplugged the old defrost timer and plugged in the new one. I then replaced everything in reverse order.
Was this helpful?