frezer not staying cold enough to freze newly added product
13 of 18 people found this instruction helpful.
  • Robert H. from Grand Blanc, MI
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part. Thank you
Was this helpful?
Thank you for voting!
Freezer would not run; no electrical power to the compressor
11 of 12 people found this instruction helpful.
  • Gary from SEQUIM, WA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Looking on-line at your diagnostic for this problem, I saw the most common part to cause this problem was the start capacitor, so I purchased one & installed it with no positive outcome. I then purchased the next recommended part which was a defrost timer & installed it with no run again. Frustrated, I looked at another diagnostic web s ite that claimed 90% of the time the problem is caused by the cold control thermostat. I tested mine and it tested bad, so I bought a control elsewhere, since your site did not list a PN for that device. I installed the new control and the freezer started up correctly. Looking at the wiring diagram for these parts, I see the start capacitor and defrost control are downstream of the cold control thermostat, and to my mind should have been the first part recommended for testing versus the parts I bought, so I am somewhat disappointed in the diagnostics on your site, where I spent about $80 for parts that were functional.
Was this helpful?
Thank you for voting!
Lost Locked Freezer Door Key
11 of 13 people found this instruction helpful.
  • Robert from San Rafael, CA
  • Difficult
  • Less than 15 mins
Had to drag the full freezer out from the wall to expose the name plate, got the Model # and S/N and found the key on the partselect website in minutes. It was cheap so I got two. Other than FEDEX not knowing my address correctly, when I finally got the key it worked fine. Not a problem anymore.
Thanks
Was this helpful?
Thank you for voting!
Freezer and refrigerator stopped cooling
8 of 8 people found this instruction helpful.
  • Amy from PITTSBURGH, PA
  • Easy
  • Less than 15 mins
  • Screw drivers
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.
Was this helpful?
Thank you for voting!
Evap fan motor intermitant
11 of 17 people found this instruction helpful.
  • Mike from Los Banos, CA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Removed evap cover from Commercial Refrigerator. Removed mounting screws from Evap motor mount. Replaced evap fan motor. Repositioned. Reinstalled evap cover. Tested . This motor was hard to find locally. Glad I called.
Was this helpful?
Thank you for voting!
Freezer Door Leaking
8 of 8 people found this instruction helpful.
  • Danielle from LAKEWOOD, CO
  • Very Easy
  • Less than 15 mins
My issue was water leaking from the door. I thought it was the gasket, so I removed the gasket and the entire panel off of the door. There was water behind it that had soaked the cardboard seal, so I left that front part off for over a week to let it dry. We determined between us and our two toddlers that perhaps the door hadn't been prop erly closed enough on a number of occasions, so before I bought a $100 gasket, I'd try making sure the door was shut with tape, turning the freezer on and seeing what happened. There was no water after a few days, so on another user's suggestion I purchased the $15 key and twist tied it to the freezer door. Now I am locking the door after use so we won't have leaking water any longer.
Was this helpful?
Thank you for voting!
Freezer not defrosting
8 of 9 people found this instruction helpful.
  • Tom from Argyle, WI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
Was this helpful?
Thank you for voting!
defrost thermostat was open most of the time and didn't let the defrost element heat up.
9 of 13 people found this instruction helpful.
  • Elvin from Gardner, KS
  • Easy
  • 15 - 30 mins
  • Nutdriver
Removed evaporator cover, unplug 2 wires to thermostat, unclipped it from the coil. Installed new themostat back the same way.
Was this helpful?
Thank you for voting!
Squealing noise and bottom half of freezer only froze
6 of 6 people found this instruction helpful.
  • Walter from SALT LAKE CTY, UT
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
I removed the shelves, unscrewed the cover panel of the fan motor and regulator dial, disconnected the fan motor from power, unscrewed 2 screws holding the motor to the mounting bracket and put the new motor in it's place. New motor had no thread in the mounting holes, so I put new tread in so I could use the 2 screws. Another option woul d have been to drill all the way through the mounting holes and use longer screws or bolts. Of course I turned the power off before I started repairs. Freezer runs like new now. Technicians wanted $400 for the job, while it cost me a mere $55 for the Motor.
Was this helpful?
Thank you for voting!
The freezer was not keeping food frozen
6 of 7 people found this instruction helpful.
  • Jeffry from VERONA, WI
  • Easy
  • 1- 2 hours
  • Screw drivers
I replaced the timer and the defrost thermostat. The defrost thermostat replacement was almost exactly like the training video here. The old part attached slightly differently. The most time consuming part was thawing out the heat exchanger, which was completely covered with ice, inside and out.

Compared to the training video, the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Was this helpful?
Thank you for voting!
Freezer was freezing solid
6 of 7 people found this instruction helpful.
  • Matt from Cincinnati, OH
  • Easy
  • Less than 15 mins
  • Pliers
I first replaced the defrost timer about a week prior and it did not correct the problem. I then ordered the thermostat from partselect and within 15 minutes had the part installed. My refridgerator has been running correctly for a couple weeks.
Was this helpful?
Thank you for voting!
Freezer was running too warm
6 of 8 people found this instruction helpful.
  • Jeanne from SAN ANTONIO, TX
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Was this helpful?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
5 of 5 people found this instruction helpful.
  • Bruce from MARTINEZ, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.

After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.

I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.

I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Was this helpful?
Thank you for voting!
Refigerator Not Staying Cold
5 of 5 people found this instruction helpful.
  • Marsha from BEVERLY, MA
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Wrench set
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
Was this helpful?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
5 of 7 people found this instruction helpful.
  • gary from ARANSAS PASS, TX
  • Easy
  • 30 - 60 mins
  • Nutdriver
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Was this helpful?