no on/off knob
1 person found this instruction helpful.
  • Susan J from Oneonta, NY
  • Really Easy
  • Less than 15 mins
even I can replace a control knob....
Was this helpful?
Thank you for voting!
door frame cracked
1 person found this instruction helpful.
  • Christopher from Cherry Valley, MA
  • Easy
  • 15 - 30 mins
  • Screw drivers
Frist removed locking clip,lifted door,removed damaged part an replaced door.
Was this helpful?
Thank you for voting!
Unit would not heat
1 person found this instruction helpful.
  • william from LA VERNE, CA
  • Easy
  • 30 - 60 mins
  • Pliers, Socket set, Wrench (Adjustable)
Used a Motor cycle Jack to remove both unites combined. Removed side panels exposing internal working parts. Removed nonworking Magnetron and replaced it with new Magnetron. The process was completed in about 1 hour.
Was this helpful?
Thank you for voting!
Microwave fan would come on when door open. Timer and unit would not switch on.
1 person found this instruction helpful.
  • Dick from SANDY, UT
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
I looked up my problem on the internet and found a very helpful video. Microwave on video was different brand but the internals and methods were very much the same. The video made it simple and easy to fix. Found the replacement switch on the LG parts site and ordered. Two different switch types. One with red switch, the other green. Part was $7.28. Saved a bundle in service costs. Here is the repair video.

https://www.youtube.com/watch?reload=9&v=_AglBJoHgDs
Was this helpful?
Thank you for voting!
Microwave wouldn’t heat
1 person found this instruction helpful.
  • Rex from ROSEVILLE, CA
  • Really Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
I want to preface this review by stating that I do some DIY from YouTube, but have no experience in electronic repair. The microwave is over the stove with the extendavent. First I unplugged the microwave, removed the vent and started to unscrew the microwave from the mount. I used a power drill to speed things up. I was able to remove the microwave on my own. I unscrewed the lid on the microwave and took the lid off and there is the magnetron. I opened up needle nose pliers to have each end touch the terminals of the capacitor (holds the power, Dangerous). I made sure to keep my hands on the rubber handles and avoid touching the metal part of the pliers. I used the pliers to remove the plug of the capacitor to the magnetron as well. The magnetron has 4 screws (2 top, 2 bottom). There is a magnet that can hold the screws to keep from falling but I’d still recommend a screwdriver with a magnet on the end. The magnetron has another set of wires connected by a metal bracket like a holder, not really connecting any wiring to the magnetron itself. I had to unscrew 1 screw to removed that. Adding everything back on was easy, same steps back. I plugged in the microwave and tested a cup of water before I mounted it back above the stove. Voila! I did need my wife’s help to hold the microwave on the hinge while screwing into the mount. It doesn’t take a lot of muscle for the help. $85 for the part and ~40 mins to fix a $400 microwave!
Was this helpful?
Thank you for voting!
A/C coils would freeze up and unit would not shut off with temperature control.
1 of 2 people found this instruction helpful.
  • Travis from Locust Grove, GA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Unplugged unit.
Pulled front cover and removed switch knobs.
Pulled switch plate off and replaced thermostat switch and temperature sensor bulb assembly.
Reassembled and plugged in.
Unit works normal.
Was this helpful?
Thank you for voting!
no heat
0 of 1 people found this instruction helpful.
  • Nelia from Streamwood, IL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
unplug the unit then pull down , lot of screws are on top. open the cover . you could see the parts that need to replace on the right hand side (heavy side). disconnect wires then test the parts that need to replace by a tester to make sure that it's really broke .then unscrew part and replace .
Was this helpful?
Thank you for voting!
Microwave operated but did not heat
3 of 10 people found this instruction helpful.
  • Donald from Oak Ridge, TN
  • Easy
  • 1- 2 hours
  • Screw drivers
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.
Was this helpful?
Thank you for voting!
Both motor clips broken - >40 year old dryer!!
1 of 4 people found this instruction helpful.
  • susan from Socorro, NM
  • A Bit Difficult
  • 30 - 60 mins
Removed the back - Saw the broken clips on the base of the dryer (the wires to the motor were pulling out because the motor was slipping).

Guessed that the parts were motor clips (no pix in the web site!)

Got the parts in post - they were identical except needed some rubber grips inside to hold tight (Used pieces of bike tire inner tube cut to fit for this.) Attached clips. Works fine!!

(Son is an engineer - he found the problem. Husband is a retired doctor - he couldn't!! but together they
supplied the muscle)
Sue (67 years old)
Was this helpful?
Thank you for voting!
Replacement of Magnetron
0 of 1 people found this instruction helpful.
  • Benjamin from Anchorage, AK
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I UNPLUGGED the microwave and removed the cover, using a phillips and a Torx screwdriver for the machine screws. I set these screws aside, so as not to confuse them with the later encountered screws. I photographed the magnetron to assure proper placement of the 6 phillips machine screws involved in reassembly (marking the the locations on the old magnetron would do as well. I marked the old magnetron "old", to avoid later confusion. I removed the two screws holding the shields to the magnetron. I removed 3 of the 4 screws holding the magnetron to the microwave, leaving one of the top screws. I held the magnetron securely and removed the last screw, pulling out a the part of the magnetron that penetrated the microwave. I installed the new magnetron in reverse order. One problem I encountered was locating one of the six screws, which had been pulled into the old magnetron by magnetism.
Was this helpful?
Thank you for voting!
burnrd out light
  • Harlan from Logan, KS
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Removed cover and installed light
Was this helpful?
Thank you for voting!
Bulb out
  • Kenneth from Millsboro, DE
  • Really Easy
  • 15 - 30 mins
"PIECE OF CAKE" Removed cover,removrd bulb, replaced bulb, replaced cover. "PIECE OF CAKE" P.S. Wife is happy.
Was this helpful?
Thank you for voting!
Microwave worked intermittently
  • Robert from Palmer Lake, CO
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Screw drivers
The door was not engaging the micro switches properly no doubt from 10+ years of wear. The upper switch removed fairly easily but take care not to tweak the plastic brace too much or it will snap. The lower one was the tricky one. After much examination I noticed that the trick to remove it was underneath the brace. Take a butter knife (n o joke) and insert it just under the old micro switch and gently press down twisting the micro switch every so slightly til it releases. The replacements snap back in with no trouble. The microwave is working much better now, though not perfect.
Was this helpful?
Thank you for voting!
replace light bulb and security latch
  • David from Bishopville, MD
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers, Socket set
you will a security socket T20. this unit was installed over oven, remove trim cover,remove screws holding unit in place,I used a helper to get the unit out, once out you have to remove all the screws holding the cover on,on two of the corners they use a security hex screw so you need a special socket for that. remove the door latch switc h,take your time or you will break tab holding switch in. ask me how I know.but super glued broke piece in place and plugged wire back in.the new latch may have a second pin but look at old one and plug wires in the same way.the light bulb does not screw out so I had to purchase the entire unit.total cost under a $100.00 to do repair.
Was this helpful?
Thank you for voting!
Motor quit working but light and timer still worked.
  • Thais from La Grange, TX
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Since others reported similar problems and it was just the fuse we tried that first. That wasn't the problem so we ordered the Door Interlock Switch Kit. Shipping was very fast! Our microwave had 3 switches. My husband asked how to know which one to switch. I read that one person just did process of elimination. Luckily ours worked on the first change out! So happy to have stumbled across this site and not have to buy a whole new microwave.