Refrigerator Ice Maker stopped making ice.
18 of 34 people found this instruction helpful.
  • Harold from Oakton, VA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!
Was this helpful?
Thank you for voting!
Water would not dispense
11 of 13 people found this instruction helpful.
  • Emile from Oceanside, CA
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers
First turned off the water at the valve. Next I undid the 5 screws holding the plate that holds the pump. Next disconnected the power connectors, then the water lines. Next undid the screw holding the pump, removed pump. Next, mounted the new pump to the plate, this was tricky because it has to fit kind of upside down, so you have to wrangle it into the proper position then align the screw hole. Next, secured it to the plate with the screw, re-connected the water lines, then the power. Before mounting it back to the fridge, I tested to see if it worked, well, it didn't. My heart sank. I re-checked all connections, I redid the entire process, disconnected and re-connected and still did not work. I researched the problem online and someone posted maybe the water filter might be clogged or defective. So I removed the water filter and put the stop plug in, and it worked perfectly. I went and exchanged the filter and plugged it in and still had the same problem. I am now suspecting the filter receptacle is the fault, but we will do without that for the time being. But the pressure is much better so changing the pump was still necessary. All in all a very interesting repair. I learned a lot about how the system works and now I need to replace the damper, it is very noisy.
Was this helpful?
Thank you for voting!
Remove the water filter to install the bypass cap
11 of 14 people found this instruction helpful.
  • Phil from GREENFIELD, IN
  • Very Easy
  • Less than 15 mins
  • Pliers
Lower the filter bottom housing to gain access to the filter. Unscrew the filter and install the bypass cap. Secure the lower filter housing to the top assembly.
Was this helpful?
Thank you for voting!
Six months in use time to replace the filter
13 of 20 people found this instruction helpful.
  • Michael from Long Valley, NJ
  • Easy
  • Less than 15 mins
It is simple, unscrew the old screw in the new one.
Was this helpful?
Thank you for voting!
Refrigerator not defrosting properly. Evaporator froze on three different occasions.
10 of 11 people found this instruction helpful.
  • John from GREENSBURG, PA
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
I watched the video provided on-line in your website, which was excellent. The information provided gave me everything I needed to change the board. I already had experience handling control boards and was aware of the static precautions; however, your paperwork was very good detailing how to program the new board. The only small probl em I had was reinstalling the temp sensor in its bracket. The lead was very short. Other than that, all went well! The project took between 20 and 30 minutes.
Was this helpful?
Thank you for voting!
frig would not get cold
10 of 12 people found this instruction helpful.
  • dennis j from TOMAHAWK, WI
  • Very Easy
  • 15 - 30 mins
  • Screw drivers
I watched video for repair and it went just like it showed. piece of cake
Was this helpful?
Thank you for voting!
left refrigerator out in freezing weather
10 of 12 people found this instruction helpful.
  • David from waunakee, WI
  • Easy
  • 15 - 30 mins
  • Socket set, Wrench (Adjustable)
Went on line to find replacement valve.
Received the new part and compared to broken part. Both the same.
CAREFULLY removed the broken valve. Paying attention to how it came off.
CAREFULLY put it on the same way it came off.
This is a plug and play part. Just had to reconnect the water line.
Saved at least 75 do llars.
Easy to find the part on your site.
Was this helpful?
Thank you for voting!
Leaking water tube connector/union
10 of 12 people found this instruction helpful.
  • Roderick from NEWTOWN, PA
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
Received the union I ordered, then discovered that the tubes were different sizes, so I had the wrong part. I had read elsewhere that it was necessary to trim the two ends of the tubes with a box cutter to stop the leaks - I did this, and the leaking stopped. I was then able to go to a local hardware store and get a 5/16 to 1/4 union and replace it. The leaking is stopped, and the water supply in the door is now working like new. No problem with partselect, but I did buy a caliper so that I can check tube diameters if I ever have a similar problem! This is a great site to find instructions - well worth the time to search!
Was this helpful?
Thank you for voting!
Defrost thermostat failed causing ice build up
11 of 15 people found this instruction helpful.
  • Gwen from Vista, CA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Once I figured out where the part was located it was quite simple. I thawed out the freezer first. Using a nut driver, I removed all the screws to the back panel of freezer. Squeezed the clips on the ice maker attachment to release the panel. Once I opened the panel the thermostat was visible and accessible. The failed thermostat was obvi ous by its bulging appearance. By following the instructions found on Partselect.com, I cut the two connecting wires and removed the failed part. I then striped some insulator from the wires to connect the new part. I used electrical tape to ensure connection and insulation as the white wire connectors did not work well (too big) for my application. Closed everything back up, plugged in refer and all was good. A little time and a $20 part saved me $150. Thanks Part Select!
Was this helpful?
Thank you for voting!
Defrost not working
11 of 15 people found this instruction helpful.
  • Glenn from Santa Rosa, CA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
There were three parts in question, the defrost timer (inside the casing near the control dial at the top of the refridgerator), the defrost thermostat (behind the back wall of the freezer), and the heater coil (ditto). We tested the defrost timer by opening it up, advancing it to the defrost cycle, and waiting for the compressor to star t up again, showing that the timer was working. Then we replaced the defrost thermostat and found that the heater coil worked.

The hardest part was figuring out how to open the casing and get to the timer. If I do it over again I will replace the $20 thermostat first and then deal with the timer if necessary. To get to the thermostat you can easily take the freezer door off by removing two screws in the door tracks. There was even an arrow pointing to one of the screws! Take out the food trays and then unscrew the back wall with a nut driver. The thermostat was clipped to one of the copper freezer tubes. I unplugged one end of the thermostat circuit at the lead to the heater coil and then cut the thermostat out of the circuit and used wire nuts to connect the new thermostat.
Was this helpful?
Thank you for voting!
Cracked plastic on pantry drawer lid
10 of 12 people found this instruction helpful.
  • Angela from Bay Village, OH
  • Really Easy
  • Less than 15 mins
Broken lid popped out, new lid popped in. No tools required. 30 seconds to replace. Great price, part shipped within an hour of placing my order and arrived the next day, although I only paid for standard shipping. Excellent service - will definitely order again if the opportunity arises!
Was this helpful?
Thank you for voting!
Plastic peg hinging lid to drawer broke
9 of 9 people found this instruction helpful.
  • Lee from North Potomac, MD
  • Really Easy
  • Less than 15 mins
  • Screw drivers
It actually took 1 day and 15 minutes to fix this problem.

I removed the drawers and shelves in the area around the pantry. I carefully took apart the sliders and plastic parts that comprise the endcap/temperature adjuster. Then I tried to replace the unbroken part into the assembly. At that point I realized that something was wrong and I had ordered the wrong part. So I cleaned and put the broken part back in the refrigerator to wait for the replacement.

PartSelect customer service person was terrific and had the correct part on the way to my home immediately. I don't know how, but it arrived the NEXT day!

THEN, it took me 15 minutes to unscrew the sliders, endcap and replace both.
Thank you PartSelect.
Was this helpful?
Thank you for voting!
The frost free drain behind the freezer compartment clogged and water collected in the bottom of the freezer and eventually came out the door on the right front of the refrigerator.
9 of 10 people found this instruction helpful.
  • David from ROSEBURG, OR
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
The other instructions and the video provided by Parts Direct are pretty good with instructions, but they omit two steps. First, if you have an ice maker, you will need to unplug the connector on the back side of the panel you remove at the back of the refrigerator to access the drain tube. Just unplug it and you can move the removed pa nel to the side without disconnecting any of the water lines. Second, the instructions say to just reconnect the "bottom end" of the new p-trap drain to the drain pan at the bottom of the refrigerator. They don't tell you there are two places to connect the new p-trap to the drain pan. The original tube/trough connected to the one at the back of the drain pan on the left (viewed from the rear of the refrigerator). At first, it looks like the new p-trap won't reach to it for the connection, but if you look closer, there is another connector to the right of the original one that the p-trap connects to properly. Replacing the drain trough with the new p-trap was actually pretty easy and would only take about a half hour. Add another half hour to give the refrigerator coils a good cleaning as they will need it now that you can reach them. The real time consumer, 3 to 4 hours, is needed to use a hair dryer to melt and clear the ice from the condenser at the back of the freezer so the water can drain. Just take your time and all the ice will eventually melt and drain out so the new p-trap will work properly.
Was this helpful?
Thank you for voting!
freezer no staying cold
9 of 10 people found this instruction helpful.
  • William from EXTON, PA
  • Easy
  • 15 - 30 mins
  • Screw drivers
Replaced the electronics board. Fairly easy job. Video helped enormously. Programing is awkward.
Was this helpful?
Thank you for voting!
Replacement of Amana ice maker
16 of 31 people found this instruction helpful.
  • RAYMOND from HILLSBOROUGH, NC
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
If you can take the old one out and reverse the procedure, there isn't much more to it than that.
Was this helpful?
Thank you for voting!
All Instructions for the ABL2