frig would not get cold
10 of 12 people
found this instruction helpful.
-
dennis j from TOMAHAWK, WI
- Very Easy
- 15 - 30 mins
-
Screw drivers
I watched video for repair and it went just like it showed. piece of cake
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people
found this instruction helpful.
-
Steven from Brigham City, UT
- Really Easy
- 15 - 30 mins
-
Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Read less
Was this helpful?
Thank you for voting!
Defrost not working
11 of 15 people
found this instruction helpful.
-
Glenn from Santa Rosa, CA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
There were three parts in question, the defrost timer (inside the casing near the control dial at the top of the refridgerator), the defrost thermostat (behind the back wall of the freezer), and the heater coil (ditto). We tested the defrost timer by opening it up, advancing it to the defrost cycle, and waiting for the compressor to star
... Read more
t up again, showing that the timer was working. Then we replaced the defrost thermostat and found that the heater coil worked.
The hardest part was figuring out how to open the casing and get to the timer. If I do it over again I will replace the $20 thermostat first and then deal with the timer if necessary. To get to the thermostat you can easily take the freezer door off by removing two screws in the door tracks. There was even an arrow pointing to one of the screws! Take out the food trays and then unscrew the back wall with a nut driver. The thermostat was clipped to one of the copper freezer tubes. I unplugged one end of the thermostat circuit at the lead to the heater coil and then cut the thermostat out of the circuit and used wire nuts to connect the new thermostat.
The hardest part was figuring out how to open the casing and get to the timer. If I do it over again I will replace the $20 thermostat first and then deal with the timer if necessary. To get to the thermostat you can easily take the freezer door off by removing two screws in the door tracks. There was even an arrow pointing to one of the screws! Take out the food trays and then unscrew the back wall with a nut driver. The thermostat was clipped to one of the copper freezer tubes. I unplugged one end of the thermostat circuit at the lead to the heater coil and then cut the thermostat out of the circuit and used wire nuts to connect the new thermostat.
Read less
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people
found this instruction helpful.
-
Benjamin from Daytona Beach, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
Read less
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people
found this instruction helpful.
-
JAMES from Middleboro, MA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Read less
Was this helpful?
Thank you for voting!
freezer no staying cold
9 of 10 people
found this instruction helpful.
-
William from EXTON, PA
- Easy
- 15 - 30 mins
-
Screw drivers
Replaced the electronics board. Fairly easy job. Video helped enormously. Programing is awkward.
Was this helpful?
Thank you for voting!
The frost free drain behind the freezer compartment clogged and water collected in the bottom of the freezer and eventually came out the door on the right front of the refrigerator.
9 of 10 people
found this instruction helpful.
-
David from ROSEBURG, OR
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
The other instructions and the video provided by Parts Direct are pretty good with instructions, but they omit two steps. First, if you have an ice maker, you will need to unplug the connector on the back side of the panel you remove at the back of the refrigerator to access the drain tube. Just unplug it and you can move the removed pa
... Read more
nel to the side without disconnecting any of the water lines. Second, the instructions say to just reconnect the "bottom end" of the new p-trap drain to the drain pan at the bottom of the refrigerator. They don't tell you there are two places to connect the new p-trap to the drain pan. The original tube/trough connected to the one at the back of the drain pan on the left (viewed from the rear of the refrigerator). At first, it looks like the new p-trap won't reach to it for the connection, but if you look closer, there is another connector to the right of the original one that the p-trap connects to properly. Replacing the drain trough with the new p-trap was actually pretty easy and would only take about a half hour. Add another half hour to give the refrigerator coils a good cleaning as they will need it now that you can reach them. The real time consumer, 3 to 4 hours, is needed to use a hair dryer to melt and clear the ice from the condenser at the back of the freezer so the water can drain. Just take your time and all the ice will eventually melt and drain out so the new p-trap will work properly.
Read less
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people
found this instruction helpful.
-
Lori from Chuluota, FL
- Easy
- Less than 15 mins
-
Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
Right hand door would not auto close.
16 of 31 people
found this instruction helpful.
-
Bill from Murphy, NC
- Easy
- Less than 15 mins
-
Nutdriver
Removed the top door hinge cover.
Remover the four 12mm hex screws.
Lifted empty door off bottem hinge support.
Removed old door closure.
Put some silicon lub on the new closure and installed.
Reversed the removal steps.
But this did not fix the problem. Will have to remove the door and inspect the insi ... Read more de of the door's lower hinge assembly.
Remover the four 12mm hex screws.
Lifted empty door off bottem hinge support.
Removed old door closure.
Put some silicon lub on the new closure and installed.
Reversed the removal steps.
But this did not fix the problem. Will have to remove the door and inspect the insi ... Read more de of the door's lower hinge assembly.
Read less
Was this helpful?
Thank you for voting!
Icemaker Would Not Produce Ice
8 of 8 people
found this instruction helpful.
-
ROBERT from INVERNESS, IL
- Easy
- 15 - 30 mins
-
Nutdriver
Contacted sears home service to perform repair. Quote for repair was $307. 43. ( $196. 90 For labor ,$102. 58 For part) plus $75. 00 For service call. Based on the charge, I refused the repair and ordered the appropriate part from "part select" (733947) (wpl 8201515) motor module for a cost of $81. 84. To my surprise, the part arrived
... Read more
the next day and in 15 minutes the icemaker was in a position to make ice, and has been producing ice ever since. To perform the module replacement, I had to remove one screw with a nutdriver, pull the icemaker out, disconnect a wire harness, replace the module and do the reverse procedure to complete the installation. I saved a total of $225. 59 By doing this repair myself. A lesson learned. . . . . I will always investigate doing a repair myself with the help from the people at part select. Very professional and they sent the correct part the first time.
Read less
Was this helpful?
Thank you for voting!
broken light switch
12 of 20 people
found this instruction helpful.
-
Richard from West Warwick, RI
- Really Easy
- Less than 15 mins
-
Screw drivers
followed the instructions provided and that's it!
Was this helpful?
Thank you for voting!
Ice maker motor would run continuously but the blades would not turn and no ice came out.
9 of 11 people
found this instruction helpful.
-
Gary from Medway, MA
- Really Easy
- Less than 15 mins
-
Screw drivers
I wasn't sure what the problem was, but the ice maker seemed simple and on-line resources suggested the control and motor assemblty was at fault. I searched the internet and Partsource had great diagrams which I could match to the part in hand. The price was right (way less than the local stores) so I ordered it.
I unplugged the unit ... Read more from the power in the freezer, but unplugging the entire refrigerator works too. I pried off the white cover on the front of the ice maker, which snaps in place top and bottom. There are three screws holding the contoller (the entire front piece), remove them, pull off the controller and push the new one in place. You may have to turn the blade shaft to line up the notch on the shaft to the motor. Then reinstall the three screws, The screws go into plastic so it is easy to cross thread them, so be careful, I actually think I did with no ill effects. Snap on the cover and repower the unit. Done. Simple and quick.
I unplugged the unit ... Read more from the power in the freezer, but unplugging the entire refrigerator works too. I pried off the white cover on the front of the ice maker, which snaps in place top and bottom. There are three screws holding the contoller (the entire front piece), remove them, pull off the controller and push the new one in place. You may have to turn the blade shaft to line up the notch on the shaft to the motor. Then reinstall the three screws, The screws go into plastic so it is easy to cross thread them, so be careful, I actually think I did with no ill effects. Snap on the cover and repower the unit. Done. Simple and quick.
Read less
Was this helpful?
Thank you for voting!
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
10 of 14 people
found this instruction helpful.
-
Kenneth from Newton Grove, NC
- Really Easy
- Less than 15 mins
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people
found this instruction helpful.
-
George from Glenwood, MN
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws
... Read more
and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Read less
Was this helpful?
Thank you for voting!
Inlet valve was leaking water...
9 of 12 people
found this instruction helpful.
-
Michael E from Green Bay, WI
- Really Easy
- 15 - 30 mins
-
Screw drivers, Socket set, Wrench (Adjustable)
Took the valve off from the back of the frig and reinstalled the part I purchased from Part Select. The part was an exact OEM part, not a substitute that others had. The install went very smooth and once again we have water and ice from our frig. Can't thank Part Select enough for the thier sales team and the order department. They made s
... Read more
ure that I got the exact part that I needed. Customer for life.... Mike D. Wisconsin
Read less
Was this helpful?
Thank you for voting!