My refrigerator ran constantly and never got cold!
11 of 12 people
found this instruction helpful.
-
Brandon from Fort Wayne, IN
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
On a whim I looked into what it would take to fix my garage older 2nd fridge. I was thinking I needed a new seal, but when I checked the website there was a great troubleshooter. I would have never guessed that the defrost timer was what would cause it not to ever get cold. After a fairly simple repair the freezer is colder than ever a
... Read more
nd I actually had to turn it down. The only complication was the fridge was stuck in a defrost cycle so I had to reset the timer to get the refrigerator running. Thanks so much for a super helpful site for a do-it-yourselfer like me.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Replaced Freezer Door and Refrigerator Door Gaskets
11 of 13 people
found this instruction helpful.
-
Robin from VENICE, FL
- Really Easy
- 15 - 30 mins
-
Screw drivers
!st removed the doors from the unit, then laid them on the floor. Next, on a long side of the door, cut through the gasket so I could pull it off the door in one piece without separating the door liner from the outer door. Then, starting at a corner, started pushing the stiff black part of the replacement gasket between the liner and oute
... Read more
r door, making sure to push it completely under as I went. Used a thick flat bladed screwdriver to carefully help push the final corner section in. Repeated on both doors, rehung, plugged in and done!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
would not cycle
12 of 16 people
found this instruction helpful.
-
Maxine from Birmingham, AL
- Really Easy
- 15 - 30 mins
-
Nutdriver
removed the defrost timer and replaced with new unit now i have a refrigerator again
Was this helpful?
Thank you for voting!
Crisper Drawer cover broke.
10 of 11 people
found this instruction helpful.
-
Monica from Greendale, WI
- Really Easy
- 15 - 30 mins
-
Screw drivers
We removed the drawers and drawer cover
(after we'd unloaded that part of the refrigerator!), and
took the glass out of the drawer cover. Then we took
the gaskets off the old cover and put them on the new
one (that's what the screwdriver was for).
It was easy because of the very helpful diagram of all
t ... Read more he parts that I had used on the web site to order the
part.
Getting the part was amazingly fast - thank you!
(after we'd unloaded that part of the refrigerator!), and
took the glass out of the drawer cover. Then we took
the gaskets off the old cover and put them on the new
one (that's what the screwdriver was for).
It was easy because of the very helpful diagram of all
t ... Read more he parts that I had used on the web site to order the
part.
Getting the part was amazingly fast - thank you!
Read less
Was this helpful?
Thank you for voting!
Broken gooseneck on fill tube
10 of 11 people
found this instruction helpful.
-
Thomas from Brunswick, OH
- Really Easy
- 15 - 30 mins
-
Screw drivers
The gooseneck on the icemaker fill tube extends out beyond the back cabinet of the refrigerator, and is easily broken. Luckily, this part is a piece of cake to replace. You'll literally spend more time pulling out your fridge and cleaning out behind it then you will replacing this part.
Shut off water supply line, and turn of ... Read more f ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.
Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Shut off water supply line, and turn of ... Read more f ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.
Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Read less
Was this helpful?
Thank you for voting!
Didn't know if I needed Left or Right.
11 of 14 people
found this instruction helpful.
-
Joyce from Kerrville, TX
- Really Easy
- Less than 15 mins
The item is listed as R, meaning right hand side. If you need it for the left hand side, simple turn it over. It is designed to work on both sides of the door.
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people
found this instruction helpful.
-
Steven from Brigham City, UT
- Really Easy
- 15 - 30 mins
-
Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Read less
Was this helpful?
Thank you for voting!
socket melted with bulb in it.
12 of 18 people
found this instruction helpful.
-
martin l. from JACKSONVILLE,, IL
- Really Easy
- Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
bottom hinge on refrigm door squeaked
13 of 21 people
found this instruction helpful.
-
william from williamstown, NJ
- Easy
- 15 - 30 mins
-
Socket set
removed all items stored on door,removed screws holding bottom hinge to frame, placed door on floor while cleaning bottom of door, placed washer on hinge, reinstalled door on fridge, placed hinge on frame and secured with screws.
Other Parts Used:
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people
found this instruction helpful.
-
Benjamin from Daytona Beach, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
Read less
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people
found this instruction helpful.
-
JAMES from Middleboro, MA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Read less
Was this helpful?
Thank you for voting!
part of a freezer support bracket was missing
9 of 10 people
found this instruction helpful.
-
peter from saint augustine, FL
- Really Easy
- Less than 15 mins
I wasn't sure the kit included the part I needed from the pictures, but it did. The part slipped over the flat plastic bracket attached to the right freezer wall and the shelf fit over it. No tools required.
Was this helpful?
Thank you for voting!
I cracked mine :D
11 of 16 people
found this instruction helpful.
-
Lisa from Fort Myers, FL
- Really Easy
- Less than 15 mins
Slid right in...exceptionally easy :)
Was this helpful?
Thank you for voting!
Broken parts in refrigerator
11 of 16 people
found this instruction helpful.
-
Harald from Cape Coral, FL
- Really Easy
- Less than 15 mins
Replaced with new parts
Other Parts Used:
Was this helpful?
Thank you for voting!
The refrigerator leaked water every time the ice maker filled.
11 of 16 people
found this instruction helpful.
-
Robert E. from Darien, IL
- A Bit Difficult
- Less than 15 mins
The problem was discovered to be a cracked fill tube head, This part extends behind the refigerator and is VERY vulnerable to breakage when the box is pushed backagainst a wall space! Placing a shim under the vertical part of the fill tube fixed the problem even without replacing it with the new part. So, now I have a spare!
Was this helpful?
Thank you for voting!