Refrigerator Wasn't Cooling,Evaporater Coil Freezing Up
38 of 50 people
found this instruction helpful.
-
Robert from Doral, FL
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment. The bi-metal switch was right there in plain view. There are two colored wires that come out of
... Read more
the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good
Read less
Was this helpful?
Thank you for voting!
Freezer wasen't cooling refrigerator
36 of 45 people
found this instruction helpful.
-
Joann from ATCHISON, KS
- Really Easy
- 15 - 30 mins
-
Screw drivers
Removed the old defrost heater screws and connected the new one. I have 46 apartment units here and have had about 15 defrost heater's replaced by service repair person at a very expensive cost. To my surprise it was extremly easy and a lot less in cost.
Was this helpful?
Thank you for voting!
Defrost timer was faulty. It would not restart on it's own.
33 of 47 people
found this instruction helpful.
-
Ed from Frankfort, IN
- Really Easy
- 15 - 30 mins
-
Screw drivers
Just removed the old timer and attached the wires to the new one and replaced the old. That simple!
Was this helpful?
Thank you for voting!
Fridge Air On, Not Cooling
78 of 183 people
found this instruction helpful.
-
Robert from Austin, TX
- Really Easy
- Less than 15 mins
-
Pliers
Previous issue with this refrigerator and I figure after the Hot summer we've had in TX that it overworked itself this summer in the garage! Caught this one before all was lost as it started it's not cooling cycle on a Sunday. Ordered the identical Relay&Overload from Parts Select, 2 days later I'm back to chilling the beer again! Supe
... Read more
r service with diagrams and specs. Very glad parts select is around!
Read less
Was this helpful?
Thank you for voting!
The light switch on the refridgerator broke - no light.
36 of 58 people
found this instruction helpful.
-
David from Albany, OR
- Really Easy
- Less than 15 mins
-
Screw drivers
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.
The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.
I'm very pleased!
The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.
I'm very pleased!
Was this helpful?
Thank you for voting!
REplaced ice maker
30 of 42 people
found this instruction helpful.
-
M from Lafayette, IN
- Really Easy
- Less than 15 mins
-
Nutdriver
Replacement was very easy as new ice maker was identical to the old one. Took about 10 minutes.
Was this helpful?
Thank you for voting!
Evaporator Fan had quit running
25 of 28 people
found this instruction helpful.
-
Duane from Piper City, IL
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
After unplugging the fridge, I removed all the phillips head screws from the evaporator fan housing as well as the back cover and the bottom of the freezer compartment (7) in all. After first removing the bottom cover - then the back cover I could access the evaporator fan unit. This was held in place with two hex-head screws that were e
... Read more
asily removed with a nut driver. Then after unplugging the Red, White, and Green wires from the fan I removed it and replaced it with the new one. I did have to break off the two ends of the mounting bracket as described in the instruction sheet since it was too wide. Repeating the above steps in reverse, I had the job done and refridgerator up and running as quiet as could be in less than 15 minutes.
Read less
Was this helpful?
Thank you for voting!
Refrigerator shutting down and then off and on
24 of 29 people
found this instruction helpful.
-
James from Aubrey, TX
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Removed the bottom panel in the freezer and then the back plate and then seen the defrost thermostat attached to condenser.Unpluged the wiring harness and clipped the zip ties and installed new thermostat and wiring harness and reinstalled in reverse order.Plugged in refrigerator and has worked fine ever since.The response time of Partsel
... Read more
ect was very quick ,and helpful webite as well to find parts needed.Will use anytime in the future for sure.
Read less
Was this helpful?
Thank you for voting!
bottom not cold and freezer back iced up
23 of 27 people
found this instruction helpful.
-
Sid from Houston, TX
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
I automatically assumed it was the defrost timer contcts or motor due to 2 previous experiences. After seeing troubleshooting guide in check out page of partselect.com site I tested the 2 other components and found defective defrost thermostat. Thanks to this guide I saved a lot of time and cost.
Was this helpful?
Thank you for voting!
Ref was warm freezer was still freezing
25 of 36 people
found this instruction helpful.
-
richard l. from franklin, KY
- Really Easy
- Less than 15 mins
-
Socket set
check what site said was probably the problem 80% of the time. took out one screw unit dropped down disconnected part
connected new part screwed unit backup. Waited 4-5 hrs temp went from 60 degrees to 40.
connected new part screwed unit backup. Waited 4-5 hrs temp went from 60 degrees to 40.
Was this helpful?
Thank you for voting!
Refrigeator would not drfrost...
27 of 44 people
found this instruction helpful.
-
Curtis from Pikeville, KY
- A Bit Difficult
- 1- 2 hours
-
Pliers, Screw drivers, Socket set, Wrench set
I just removed a few screews and took the cover out of the ice box. Put my voltage meter to the refrigeator and realized the the unit was not defrosting...I then got the part number and entered it in on your web site. A few days later my part arrived. I put the part on and in just about 20 minutes I was up an running again...Thank you
... Read more
Part Select for fast and great service. I own 35 rental properties and having a online appliance parts store really saves me a lot of time and money.
Thank you
Curtis Hall
Thank you
Curtis Hall
Read less
Was this helpful?
Thank you for voting!
Orig Ice maker died
18 of 21 people
found this instruction helpful.
-
Al from Frankfort, IL
- Easy
- 15 - 30 mins
-
Nutdriver, Wrench (Adjustable)
I was able to salvage the existing wiring and simply replace the ice maker itself and the valve located at the bottom-rear of the frig.
Simply removed and replaced the screws, changed the water tube and connected everything back up. I probably spent more time cleaning behind the frig that replacing the parts.
Very p ... Read more leased with how quickly the parts came and everything was included!
Simply removed and replaced the screws, changed the water tube and connected everything back up. I probably spent more time cleaning behind the frig that replacing the parts.
Very p ... Read more leased with how quickly the parts came and everything was included!
Read less
Was this helpful?
Thank you for voting!
freezer making a squealing sound
17 of 20 people
found this instruction helpful.
-
PAUL from Boiling Springs, SC
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
First I Removed the racks. Next 3 hex bolts that secured the ice maker. Undid the ponytail wiring. 3 Phillips screws to remove the metal back. unplugged the Evaporator Fan Motor. Replaced the new one. reassembled.
Was this helpful?
Thank you for voting!
compressor didnt turn on
24 of 41 people
found this instruction helpful.
-
gerardo from el monte, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
changed the starter connected to the compressor
Was this helpful?
Thank you for voting!
It was not coming out of defrost cycle
25 of 45 people
found this instruction helpful.
-
Dale from Flemingsburg, KY
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
First I installed a defrost timer, (the old timer had burnt out contacts in it) It seemed to work for a few days, then went back to not comng out of defrost cycle, I then installed a defrost thermostat. It seems to be working better than before. I found out that maybe I wasn't running it cold enough. So I turned it up colder. Now it
... Read more
works ok for 2 - 3 days, then I check the Temp in the freezer and its up to 6o. So I manually reset the timer and it works for 2 - 3 days. Don't know what to do now to fix it.
Read less
Was this helpful?
Thank you for voting!