Sometimes the condenser fan would start causing the refrigerator to overheat.
184 of 223 people
found this instruction helpful.
-
Tom from Franklin, WI
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Pliers
Unplug the appliance.
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut ... Read more and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut ... Read more and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new
Read less
Was this helpful?
Thank you for voting!
Lights inside refrigerator not working
136 of 255 people
found this instruction helpful.
-
Clint from Rayville, MO
- Really Easy
- Less than 15 mins
-
Screw drivers
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Was this helpful?
Thank you for voting!
no water getting to ice maker
80 of 95 people
found this instruction helpful.
-
Kevin from Boston, MA
- Really Easy
- Less than 15 mins
-
Screw drivers, Wrench (Adjustable)
The ice maker had been slowly dying and one day just stopped making ice. No water was getting to the trays.
I read that this could be caused by a failure of the valve, even though the continuity test indicated that the solenoid was okay.
I ordered the part Friday afternoon. It was delivered Saturday. I did the repai ... Read more r in 10 minutes.
I pulled the fridge away from the wall.
I unplugged the fridge. I closed the water supply valve.
I unscrewed the two mounting screws using a flat head screwdriver.
I pulled the old valve out from refrigerator.
Using an adjustable wrench I detached the water supply from the valve. I detached the hose leading to the ice maker from the valve.
I pulled the electrical connectors from the connectors on the valve.
I attached the hoses to the new valve, attached the electrical connector, screwed the new valve in its place, opened the water supply, plugged the fridge back in, checked for leaks, and waited for a few hours.
My ice maker is working better than it has in at least two years.
I read that this could be caused by a failure of the valve, even though the continuity test indicated that the solenoid was okay.
I ordered the part Friday afternoon. It was delivered Saturday. I did the repai ... Read more r in 10 minutes.
I pulled the fridge away from the wall.
I unplugged the fridge. I closed the water supply valve.
I unscrewed the two mounting screws using a flat head screwdriver.
I pulled the old valve out from refrigerator.
Using an adjustable wrench I detached the water supply from the valve. I detached the hose leading to the ice maker from the valve.
I pulled the electrical connectors from the connectors on the valve.
I attached the hoses to the new valve, attached the electrical connector, screwed the new valve in its place, opened the water supply, plugged the fridge back in, checked for leaks, and waited for a few hours.
My ice maker is working better than it has in at least two years.
Read less
Was this helpful?
Thank you for voting!
cocktails running out of ice
56 of 61 people
found this instruction helpful.
-
Craig from Westminster, CA
- Very Difficult
- More than 2 hours
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
filled both ice cube trays up with water and placed in the freezer.. within hours my ice oproduction was doubled! no more warm cocktails : )
Was this helpful?
Thank you for voting!
noisy fan motor
38 of 46 people
found this instruction helpful.
-
robert from nashotah, WI
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Socket set
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, c
... Read more
lose up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.
Read less
Was this helpful?
Thank you for voting!
Light Switch broke
48 of 78 people
found this instruction helpful.
-
James Richard from St. Cloud, MN
- Easy
- Less than 15 mins
-
Socket set
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only
... Read more
swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
Read less
Was this helpful?
Thank you for voting!
Water valve failed, flooded kitchen
28 of 29 people
found this instruction helpful.
-
James R from Valley Springs, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Wrench (Adjustable)
Turned off water supply and unplugged appliance. Removed lower panel on back of refrigerator with 1/4 " nutdriver. Then removed supply line, and line to icemaker. removed valve from back panel and replaced with new valve. wrapped water connections with teflon tape, turned on supply line, checked for leaks, everything o.k..Replaced back pa
... Read more
nel and in 45 minutes had first drop of ice. Job requires moderate mechanical ability and minimum tools. Saved a PANT load of money by doing it myself. VERY satisfied with Partselect.com
Read less
Was this helpful?
Thank you for voting!
Thermostat ceased to function. Fridge very cold.
33 of 47 people
found this instruction helpful.
-
Paul from Millboro, VA
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers, Wrench set
I removed control knobs and a couple of screws and forced the assembly down enough to remove the old thermostat, and insert the new one. Lucky me it was a identical replacement item. Job took about an hour.
Was this helpful?
Thank you for voting!
The light switch on the refridgerator broke - no light.
36 of 58 people
found this instruction helpful.
-
David from Albany, OR
- Really Easy
- Less than 15 mins
-
Screw drivers
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.
The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.
I'm very pleased!
The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.
I'm very pleased!
Was this helpful?
Thank you for voting!
Freezer and Fridge wouldnt cool
24 of 25 people
found this instruction helpful.
-
Janet from Hillsboro, OR
- A Bit Difficult
- More than 2 hours
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in
... Read more
the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
Read less
Was this helpful?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
27 of 36 people
found this instruction helpful.
-
Florentino from Windsor Locks, CT
- Easy
- 30 - 60 mins
-
Nutdriver
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Was this helpful?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
22 of 23 people
found this instruction helpful.
-
W from Nellysford, VA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also uns
... Read more
crewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Read less
Was this helpful?
Thank you for voting!
The old motor wouldn't turn the fan.
24 of 32 people
found this instruction helpful.
-
Bob from Hesston, KS
- Easy
- 15 - 30 mins
-
Socket set, Wrench set
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Remova
... Read more
l of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Read less
Was this helpful?
Thank you for voting!
Refrigerator (Top, non-freezer section) light switch broke & light socket bad with age.
25 of 37 people
found this instruction helpful.
-
Henry from Clinton Township, MI
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
Turned off power to Refrigerator.
1)Removed broken light switch, using a screwdriver, to gently pry it out. Then unlugged the switch from the connector. I used long nosed pliers to gently pull out the connector from inside the frig, so I could easily plug in the new light switch. I then pressed the new light switch back in place. ... Read more r />2) Remove light cover. I then unclipped the socket which holds the light bulb, I gently pulled it out and unplugged it from the two wires. I then attached the two wires onto the new light socket and clipped it back in place. Bingo done with both items practically no time!
1)Removed broken light switch, using a screwdriver, to gently pry it out. Then unlugged the switch from the connector. I used long nosed pliers to gently pull out the connector from inside the frig, so I could easily plug in the new light switch. I then pressed the new light switch back in place. ... Read more r />2) Remove light cover. I then unclipped the socket which holds the light bulb, I gently pulled it out and unplugged it from the two wires. I then attached the two wires onto the new light socket and clipped it back in place. Bingo done with both items practically no time!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Ice water valve leaking
13 of 13 people
found this instruction helpful.
-
Byron from Steamboat Springs, CO
- Really Easy
- Less than 15 mins
-
Nutdriver, Pliers, Wrench (Adjustable)
Removed two screws holding valve, removed two 1/4" water lines. disconnected wire clip from old valve.
Installed new valve, connecting water and electrical with ease.
Absolutely Simple!
Installed new valve, connecting water and electrical with ease.
Absolutely Simple!
Was this helpful?
Thank you for voting!