bulb had broken off in base that was still screwed into socket
93 of 109 people
found this instruction helpful.
-
william from san antonio, TX
- A Bit Difficult
- 15 - 30 mins
-
Pliers, Screw drivers
At first I tried to use pliers to unscrew the base,very uncomfortable working position,upside down and backwards(the microwave is installed over the range top)very limited space for your body and arms to manuver and you really cant see the base,all of this took place after the breaker was turned off ofcourse,finally figured out that you c
... Read more
an drop the entire bottom housing of the microwave by unscrewing 6 screws and the light sockets are easily accessable once you lower it,take out 1 retaining screw ,remove the entire socket and unscrewed the broken base and replaced the bulbs,I said bulbs,there is no sense in having to replace another bulb in who knows how long since only one had burned out but they were both the same age
Read less
Was this helpful?
Thank you for voting!
Clicking sound then within a minute clicking again, not cooling.
81 of 97 people
found this instruction helpful.
-
Melvin from Semmes, AL
- Easy
- Less than 15 mins
UNPLUG REFRIGERATOR. Carefully remove relay from the side of the compressor. You shouldn't need a tool to do this, if it is hard you can gently pry the edge with a flat head screw driver just to loosen. Unplug white and red wires from relay, noting that the white wire goes in the hole with a #2 stamped beside it. Shake old relay, if it r
... Read more
attles like a baby rattler then it's most likely the problem. Replace wires into the new relay and plug back into the compressor.
Read less
Was this helpful?
Thank you for voting!
buttom of refrigerator not cold
23 of 29 people
found this instruction helpful.
-
Giuseppe from brick, NJ
- Really Easy
- Less than 15 mins
-
Screw drivers
unplug it, pulled compressor start relay,which i thing it was the problem, but i replace bolt, very easy.
Other Parts Used:
Was this helpful?
Thank you for voting!
just quit working
19 of 25 people
found this instruction helpful.
-
Denise from Lowell, MI
- Really Easy
- Less than 15 mins
Bought a new
capacitor.
capacitor.
Was this helpful?
Thank you for voting!
Changing the bulb that illuminates the cooktop
21 of 33 people
found this instruction helpful.
-
LUCY from BALLWIN, MO
- Really Easy
- Less than 15 mins
-
Screw drivers
Loosen screw holding glass cover plate in place over bulb. Glass cover plate will swing down. Unscrew bad bulb, replace with good bulb, reset glass cover and tighten screw.
Was this helpful?
Thank you for voting!
would not freeze
20 of 32 people
found this instruction helpful.
-
John from Virginia Beach, VA
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
unplugged, removed old parts, replaced with new
Other Parts Used:
Was this helpful?
Thank you for voting!
Refrigerator was not cooling
17 of 24 people
found this instruction helpful.
-
Vicki from Johnson City, TX
- Really Easy
- Less than 15 mins
This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
Was this helpful?
Thank you for voting!
Refrigerator quit running
23 of 43 people
found this instruction helpful.
-
Frederic from Daytona Beach, FL
- Really Easy
- Less than 15 mins
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I
... Read more
do hope this is normal in this model? anyway it runs fine mow. Thank you.
Read less
Was this helpful?
Thank you for voting!
Stopped working, cooling.
15 of 19 people
found this instruction helpful.
-
Jennifer from Jonestown, TX
- Easy
- 15 - 30 mins
-
Screw drivers
I used a small screwdriver to disconnect wires from old starter. I connected the overload and starter, two wires. I put the unit back in the keeper, plugged the unit in, turned up the thermostat and it's working beautifully.
Was this helpful?
Thank you for voting!
mottor starts than stop.
9 of 11 people
found this instruction helpful.
-
Gilmar from Miami, FL
- Easy
- 15 - 30 mins
-
Screw drivers, Socket set
i looked byhind the freezer , the mottor has the relay connected to it.i took out the relay, and i descovery something was loose inside, i decided to take to check out at sears to see if they have in stock that especific relay. they did not have, they could order, that's when i dicided to go ahead and looking for in the internet, good i f
... Read more
ound PARTSELECT,they had the part and i was very nice attended,they sent in 2 days i had fix my freezer. thanks PARTSELECT. gilmar couto.
Read less
Was this helpful?
Thank you for voting!
Freezer and refrigerator stopped cooling
8 of 8 people
found this instruction helpful.
-
Amy from PITTSBURGH, PA
- Easy
- Less than 15 mins
-
Screw drivers
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.
Was this helpful?
Thank you for voting!
Freezer quit. Compressor would not start.
9 of 11 people
found this instruction helpful.
-
Steve from Neosho, MO
- Really Easy
- 15 - 30 mins
-
Pliers, Screw drivers
Like another post, the start relay rattled like a baby rattle. Replaced the start relay and freezer works great.
Was this helpful?
Thank you for voting!
under microwave (above stove) light
6 of 6 people
found this instruction helpful.
-
Bruce from Cleveland, OH
- Easy
- Less than 15 mins
The replacement of the light no problem, the reason the light broke; problem. The original was glued in (for transport i think) and simply trying to unscrew it out (in a very tight slot) it broke; be careful or you’ll be buying a new $20 bulb (with shipping and handling).
Was this helpful?
Thank you for voting!
Bulb burned ot
5 of 5 people
found this instruction helpful.
-
John from Fort Smith, AR
- Easy
- Less than 15 mins
-
Pliers, Screw drivers
Un screwed the cover but when i tried to remove the bulb it was broken at the base. I disconnected the power and used neddle nosed pliers to remove the base
Was this helpful?
Thank you for voting!
Inside Bulb went out.
4 of 4 people
found this instruction helpful.
-
Richard from Austin, TX
- Really Easy
- Less than 15 mins
-
Screw drivers
Remove top air grate via 2-screws. Remove metal top panel behind grate that's above bulb via 1-screw. Bulb is exposed and can be un-screwed. DONE
Was this helpful?
Thank you for voting!