Wretched screeching noise
9 of 9 people
found this instruction helpful.
-
Paul from Broadalbin, NY
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
Make sure you order a new belt and a new drum glide with the rear drum bearing assembly. If your bearing is worn out, so are the belt and drum glide!
1) Use a flat screw driver or putty knife to release the blind clips that hold the front side of the top of the dryer cabinet down
2) Swing dryer top up and remove two screws ... Read more that hold the face of the cabinet.
3) Unplug the wiring harness and remove the cabinet face.
4) Remove the 3 screws that hold the drum to the bearing assembly (accessed from inside the drum. This makes it easier to remove the drum as the bearing assembly can be difficult to remove before you see how it snaps together
5) Reach under the drum and take the belt off the motor pulley, then remove the drum
6) Remove the old bearing assembly from the socket (slide up then out)
7) Remove the two screws that hold the bearing socket to the dryer
8) Fasten the new socket to the dryer (you'll need help doing this unless you have REALLY long arms because you have to reach inside the driver and the back of the dryer at the same time)
9) Grease the socket with the supplied high temp grease
10) Bolt the new bearing assembly to the drum and put the new belt around the drum
11) Put the drum back in and snap the bearing socket in and down
12) Guide the new belt around the motor pulley & tensioner
13) Glue the new drum glide / felt piece to the front cabinet
14) Put the cabinet back together
1) Use a flat screw driver or putty knife to release the blind clips that hold the front side of the top of the dryer cabinet down
2) Swing dryer top up and remove two screws ... Read more that hold the face of the cabinet.
3) Unplug the wiring harness and remove the cabinet face.
4) Remove the 3 screws that hold the drum to the bearing assembly (accessed from inside the drum. This makes it easier to remove the drum as the bearing assembly can be difficult to remove before you see how it snaps together
5) Reach under the drum and take the belt off the motor pulley, then remove the drum
6) Remove the old bearing assembly from the socket (slide up then out)
7) Remove the two screws that hold the bearing socket to the dryer
8) Fasten the new socket to the dryer (you'll need help doing this unless you have REALLY long arms because you have to reach inside the driver and the back of the dryer at the same time)
9) Grease the socket with the supplied high temp grease
10) Bolt the new bearing assembly to the drum and put the new belt around the drum
11) Put the drum back in and snap the bearing socket in and down
12) Guide the new belt around the motor pulley & tensioner
13) Glue the new drum glide / felt piece to the front cabinet
14) Put the cabinet back together
Read less
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people
found this instruction helpful.
-
Benjamin from Daytona Beach, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
Read less
Was this helpful?
Thank you for voting!
The drier was "screeching"
9 of 9 people
found this instruction helpful.
-
Michel from CHICAGO, IL
- A Bit Difficult
- 1- 2 hours
-
Pliers, Screw drivers
First of all, the folks at Part Select have been terrific. I balled up my address and they were great in correcting my error and getting the parts promptly to me. They provide directions with the parts. And You Tube, is a wealth of information too. The process is to remove the drum and replace the nylon busihing that supports the drum
... Read more
at the back of the machine. Getting it out was no sweat. Getting the drum back in was a bit more challenging single handed. If I was going to make any suggestion it would be this is a good project for two sets of hands with the second set needed for about ten minutes. The You Tube video I watched said putting the front cover with the drum attached to the back of the unit would be the challenge and they were right. Otherwise, super easy and the results are it's back to "new" condition. Thanks again to Part Select!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people
found this instruction helpful.
-
Steven from Brigham City, UT
- Really Easy
- 15 - 30 mins
-
Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Read less
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people
found this instruction helpful.
-
JAMES from Middleboro, MA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Read less
Was this helpful?
Thank you for voting!
No water in icemaker tray.
9 of 10 people
found this instruction helpful.
-
Robert from Myrtle Beach, SC
- Really Easy
- 15 - 30 mins
-
Nutdriver
Confirmed that the solenoid controlled water valve (Part # PS358631) between the water source and the back of ice maker was defective. I did this by removing the valve and plastic hose from the back of the refrigerator and pointed the end that went into the icemaker towards the sink. I applied 110 volts to the valve and noted that no wate
... Read more
r was getting through. Replacing the valve was a snap.
Read less
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people
found this instruction helpful.
-
Lori from Chuluota, FL
- Easy
- Less than 15 mins
-
Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people
found this instruction helpful.
-
George from Glenwood, MN
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws
... Read more
and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Read less
Was this helpful?
Thank you for voting!
Ice Maker was broken
9 of 11 people
found this instruction helpful.
-
Jeff from Harleysville, PA
- Really Easy
- Less than 15 mins
-
Screw drivers
First I unplugged the refrigerator. Then I disconnected the flat plug. Then I loosened two screws and removed the origional ice maker. After the old ice maker was out I reversed the process and installed the new ice maker. The instructions said that it could take up to 24 to 48 hours before you have your first batch of ice. Two hours
... Read more
after the installation I had my first cycle of ice. One of the easiest repairs I have ever done!
Thank you.
Thank you.
Read less
Was this helpful?
Thank you for voting!
ice maker, intermittent hollow cubes, then no ice
9 of 11 people
found this instruction helpful.
-
paul from madison, WI
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench (Adjustable)
I was not sure what was causing the problem, I thought at first it was low water pressure causing the hollow ice cubes. After some trial and error testing I figured a likely cause could be the water valve in the ice maker itself. I replaced that part rather easily using the existing fasteners in about 15 or 20 minutes. The ice maker ha
... Read more
s been working flawlessly since the repair.
Read less
Was this helpful?
Thank you for voting!
Freezer frosted up quickly
8 of 8 people
found this instruction helpful.
-
James from Gulf Breeze, FL
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
I removed the panel in the back of the freezer and found the evaporator to be a complete block of ice. I defrosted it with a hairdryer. Following advice from the Partselect web site, I measured the resistance through the defrost heater. It was about 30 ohms, so I decided that it was OK. Next, I advanced the defrost timer manually with
... Read more
the compressor on until it turned off. The defrost heater did not operate. I concluded that the problem was the defrost thermostat. After installing it, the freezer worked properly.
Read less
Was this helpful?
Thank you for voting!
replacing thermostat did not help
10 of 15 people
found this instruction helpful.
-
John from Rocky River, OH
- Difficult
- More than 2 hours
-
Pliers, Screw drivers, Socket set
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiv
... Read more
er boaed. I turn off manually the icemaker, when needed
Read less
Was this helpful?
Thank you for voting!
Ice maker leaked water
10 of 15 people
found this instruction helpful.
-
Robert from Pennsylvania Furnace, PA
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers, Socket set
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector
... Read more
was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.
Read less
Was this helpful?
Thank you for voting!
didn't eject icecubes
9 of 12 people
found this instruction helpful.
-
Ronald from Marion, IL
- Really Easy
- 15 - 30 mins
-
Nutdriver
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin
Very Satisfied,
Ron Martin
Was this helpful?
Thank you for voting!
Dryer runs but produces no heat
8 of 9 people
found this instruction helpful.
-
Richard from Appleton, ME
- Really Easy
- Less than 15 mins
-
Screw drivers
Unplug the unit. The top of the dryer is held down by 2 simple friction pins. By lifting the dryer top above it's front door panel the top will swing up. Prop the top up so you can reach down the front panel. There are 2 Phillips screws about 6 inches down on the dryers front panel. Remove the 2 screws, tip the front panel toward you it w
... Read more
ill slip off the dryer drum. Remove the 2 push on wires attached to the door switch. Gently lift the front panel off the 2 hinge points at the bottom and set it aside. The parts that your going to replace are the 2 solenoids on the burner assembly. The burner assembly is located on the lower left side of the dryer. Remove the 2 Philips screws that "clamp" the solenoids in place. Pull the 3 & 2 wire friction connectors off the solenoids. Lift the clamp off the top of the solenoids. Pick the 2 solenoids up off the valve assemble. Put the 2 new solenoids on the valve assembly push the wires back on, put the clamp back on and resemble the dryer. *Note: just to make a quick check on the continuity of the solenoids. I suspended the dryer drum so it could rotate without damaging it, put my clamp on amp probe on the 120v line to the solenoids the 3 wire one was good the 2 wire one was open.
Read less
Was this helpful?
Thank you for voting!