Bad thermistor
1 person found this instruction helpful.
  • Cindy from Baltimore, MD
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Took front cover off air conditioner and pulled it a little forward out of the outdoor housing. I then flipped the LED display section out to the left and exposed the patch panel. The next step was to remove the panel with a small screwdriver and disconnect the old thermistor plug. I then plugged in the new one, remove the old one from th e grid bracket and placed the new one in. I then replaced everything else in reverse order. I have two LG air conditioners and they both have the same connection setup.
Was this helpful?
Thank you for voting!
Bad thermister, unit would run constantly without cycling.
0 of 2 people found this instruction helpful.
  • Gary from Aurora, CO
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Remove the front cover. Slide the unit forward a few inches from the case. Remove 1 screw from the top on the control box. Unsnap the old thermister leads going into the circuit board. Snap in the new thermister and place the end in the plastic holder in front of the coils. Install front cover.
Was this helpful?
Thank you for voting!
Broken fan assembly
1 of 11 people found this instruction helpful.
  • Drucilla from Vinita, OK
  • Really Easy
  • 30 - 60 mins
  • Screw drivers, Socket set
everything went great and was just as planned. We now have cool air in the shop for us to do our handy work. Thanks, Dale Heltzel
Was this helpful?
Thank you for voting!
window air conditioner up and quit--not blowing warm air, just totally quit--nothing, nada
  • Eric from Santa Fe, NM
  • Really Easy
  • 1- 2 hours
  • Screw drivers
I hotwired the compressor and fan directly to 110 volts and it all functioned so I knew it was electronics. Ordered two circuit boards and after putting the first one in it fired right up. Returned the second one. The one that was bad had all the relays on it--the one with the digital readout and switches was good, which was great beca use the old remote continued to work. Not sure if a new board would work with the old remote or if the remote needed to be replaced also...
Was this helpful?
Thank you for voting!
Board Not Working
  • STEVEN from NIOTA, IL
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Replaced it
Was this helpful?
Thank you for voting!
No power,controls would not work proper
  • Henry A. from Pensacola, FL
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Replace power plug,replaced conrol panel main assemblys
Was this helpful?
Thank you for voting!
Son broke grille with tennis ball
  • luciano from franklin square, NY
  • A Bit Difficult
  • 15 - 30 mins
Took off broken grill and put on new one
Was this helpful?
Thank you for voting!