there were directions
754 of 1282 people
found this instruction helpful.
-
Kate from Jacksonville, FL
- Very Difficult
- 30 - 60 mins
We didn't know where the product went and it was very difficult to install.
Was this helpful?
Thank you for voting!
six months the light turns red. time to replace filter
310 of 392 people
found this instruction helpful.
-
Leroy from Perkiomenville, PA
- Really Easy
- Less than 15 mins
First I shut the water off to the refrigerator.then i pushed the big button in the middle of the grille below the refrigerator door. pulled out the old filter, took the front cap off the old filter put it on the new filter. took the two red caps off the new filter. pushed the filter in till it locked in place. all done! Turned the back on
... Read more
.
Read less
Was this helpful?
Thank you for voting!
Fridge was getting too warm, ice buildup on coils.
159 of 188 people
found this instruction helpful.
-
Cathy from Winter Park, FL
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.
Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is n ... Read more ot functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.
Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket
Steps:
1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.
2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.
3: Un-clip the bi-metal strip from the evaporator coils.
4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.
5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.
6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.
7: Do the same for the ends of the wires on the (new) bi-metal strip.
8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.
9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.
10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.
11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.
12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).
13: Replace the panel that covers the coils.
14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is n ... Read more ot functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.
Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket
Steps:
1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.
2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.
3: Un-clip the bi-metal strip from the evaporator coils.
4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.
5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.
6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.
7: Do the same for the ends of the wires on the (new) bi-metal strip.
8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.
9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.
10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.
11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.
12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).
13: Replace the panel that covers the coils.
14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Read less
Was this helpful?
Thank you for voting!
Water filter replacement
141 of 185 people
found this instruction helpful.
-
Victoria from Beaverton, OR
- Easy
- Less than 15 mins
It's simple enough in theory: read the side of the box and follow the instructions. BUT you need to really push the knob in pretty hard (I am a girl, and my hand strength isn't that good). If you don't, when you turn the knob, the filter won't come out, then it's tougher. So: make sure the knob pops before you turn!
Was this helpful?
Thank you for voting!
change the water filter light was on.
101 of 125 people
found this instruction helpful.
-
Kenneth from SAn Francisco, CA
- Really Easy
- Less than 15 mins
It was ridiculously easy. Push the button on the filter canister holder at the base of the refrigerator and the spring-loaded mechanism came out smoothly. I unplugged the old filter, took the cap off the new on and plugged it in. After reinserting the filter canister holder and locking it in place, I heard the whoosh of water once agai
... Read more
n moving through the filter. Very satisfying and very easy to do.
Read less
Was this helpful?
Thank you for voting!
Lights inside refrigerator not working
137 of 257 people
found this instruction helpful.
-
Clint from Rayville, MO
- Really Easy
- Less than 15 mins
-
Screw drivers
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Was this helpful?
Thank you for voting!
Light Would Not Go On In The Refrigerator
62 of 82 people
found this instruction helpful.
-
DANIEL from MINNEAPOLIS, MN
- Easy
- Less than 15 mins
-
Screw drivers
First I removed the old lightbulb from the socket and replaced it with a new one to confirm that the bulb was not the problem. I then pryed the socket out with a flat-head screwdriver. I could tell that the socket was anchored in its hole with clips so it was relatively easy to pry it out. Once the socket was out, I disconnected the le
... Read more
ad wires and ordered a replacement socket kit from Partselect. When the new one arrived, I reconnected the lead wires to it, snapped it back into its hole, screwed in a new lightbulb, and presto!! The light was back on with no further problem. Thank you, Partselect!! A $15.00 part saved me what probably would have been at least a $100. service call and heaven knows what the technician would have told me I needed!!!
Read less
Was this helpful?
Thank you for voting!
Change Out Filter
63 of 96 people
found this instruction helpful.
-
Baerbel from Jacksonville, FL
- Really Easy
- Less than 15 mins
It turn one turn on the filter holder, pull out and put new filter in done
Was this helpful?
Thank you for voting!
Replacements
47 of 66 people
found this instruction helpful.
-
Jeanette from JEANNETTE, PA
- Very Easy
- Less than 15 mins
Nothing to it!!!
Other Parts Used:
Was this helpful?
Thank you for voting!
Auto Defrost Freezer keeps defrosting SIDE BY SIDE KITCHENAID
38 of 48 people
found this instruction helpful.
-
James from Ringoes, NJ
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
DISCONNECT POWER. Removed all shelves/baskets.Popped upper panel off (just clips in) Removed 6 screws in lower back panel ( 3 each side) slid panel in place but down. You can then easily see the defrost thermostat/defrost termination switch. Cut the wire connectors (pink n brown wire) stripped back wire, attached new defrost thermostat.
... Read more
Thermostat clips on. New thermostat ohm's at 5.5, old one was "open". Slid cover back up meeting the upper cover grooves. Screwed lower panel in. Put shelves etc back in. Plugged in. Turns on, put a bottle of water in freezer. Checked a while later, frozen. has been frozen for a week.
-James
-James
Read less
Was this helpful?
Thank you for voting!
Light Switch broke
48 of 78 people
found this instruction helpful.
-
James Richard from St. Cloud, MN
- Easy
- Less than 15 mins
-
Socket set
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only
... Read more
swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
Read less
Was this helpful?
Thank you for voting!
Refrigerator Wasn't Cooling,Evaporater Coil Freezing Up
38 of 50 people
found this instruction helpful.
-
Robert from Doral, FL
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment. The bi-metal switch was right there in plain view. There are two colored wires that come out of
... Read more
the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good
Read less
Was this helpful?
Thank you for voting!
Had to replace a hose connector at the base of my refrig/frreezer
47 of 81 people
found this instruction helpful.
-
Leo from Salem, SC
- Really Easy
- Less than 15 mins
Perhaps a helpful hint:
When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection.
I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.
LG
When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection.
I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.
LG
Was this helpful?
Thank you for voting!
Water Filter needed to be replaced
32 of 44 people
found this instruction helpful.
-
Leslie from Nipomo, CA
- Really Easy
- Less than 15 mins
It was SOOO easy, I turned and popped out the old filter and turned and snapped in the new one....I don't even think it took a whole minute to replace!!
Was this helpful?
Thank you for voting!
The light switch on the refridgerator broke - no light.
36 of 58 people
found this instruction helpful.
-
David from Albany, OR
- Really Easy
- Less than 15 mins
-
Screw drivers
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.
The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.
I'm very pleased!
The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.
I'm very pleased!
Was this helpful?