Ice was building up in the bottom floor of the freezer
This refrigerator/freezer problem had been escalating for almost a year, requiring me to frequently knock the ice buildup free with a rubber mallet. I finally decided to try to identify the problem by removing the freezer door and all of the shelves and shelf tracks (easily removed with only a phillips screwdriver). Then I removed the back plastic panel to expose the cooling coils, which were partially encased in ice. I deduced that the evaporator fan motor was failing, which blows air over the freezer cooling coils and forces the cool air up into the upper refrigerator section (which was not staying cold). I then found and ordered the fan motor from part select. Their search function and exploded drawing schematics made it easy to identify the part and part number. It seems the original part number had been superceded with a new number, which I ordered. Once it arrived after about a week, I transferred the fan blades from the old motor to the new fan motor, and after completely drying out the freezer compartment, I reinstalled all of the parts and plugged in the unit and waited. By the next day, the refrigerator was operating at peak efficiency, and the ice buildup in the freezer has not returned. I was very close to scrapping the entire refrigerator as junk, but with a little diagnostic effort and about $110 for the new motor, I have a fully functioning refrigerator again. Thanks to Part Select for a great experience.
removed the upper freezer door to access screws to remove lower door. laid bottom door on its side, removed bad bushing, put new bushing in, put bottom door back on refridge, put upper door back on fridge. Door worked easy as when new. good closure of door and story..Happy customer, and wife even happier.....thank you....
bottom door dropped slightly and bottom hinge area rubbing on steel door support
removed 3 fasteners for top door and placed freezer door aside, then removed 3 more fasteners on bottom refrigerator door and place that aside. replaced bushing on lower door bracket and reversed the above procedure to reinstall doors.
Pull off the grill cover and remove the 2 screws from the old part and simply screw in the new part. Don’t lose the screws there are no new ones with the new part. Replace cover.
Refrigerator not cooling. Fan and lights not working also.
In plug refrigerator. Pry old switch out with flat blade screwdriver. Disconnect wiring from old switch and plug into new switch. Push back into refrigerator. Plug unit back in. Lights and fan should now work. Check for cold air coming out in freezer.