Could not keep an aftermarket muffler on the engine.
15 of 20 people
found this instruction helpful.
-
Richard from KERNERSVILLE, NC
- Really Easy
- 15 - 30 mins
-
Wrench set
Once I determined what OEM muffler I needed, installation was relatively easy. I have a 1982 4hp Briggs on my Snapper tiller. There was a 90* galvanized elbow coming out of the exhaust port, with a bezel nut to lock it down. Do not remove the elbow, even though it appears that you should. If you install the muffler without the elbow the m
... Read more
uffler will parallel the the vacuum for the carburetor and can melt the rubber couplers. Use the elbow to direct the heat away from the carburetor. Use a pipe wrench to lock down the bezel nut because the weight of the muffler, especially under vibration, can work loose and fall down on the tine belt cover and melt it. The bezel nut that comes with the muffler should also be used to lock down the muffler to the threaded intake bracket that comes with the muffler, not to replace the bezel nut for the elbow.
Read less
Was this helpful?
Thank you for voting!
light inside fridge was flickering and clicking
20 of 35 people
found this instruction helpful.
-
bill from escondido, CA
- Easy
- 15 - 30 mins
-
Nutdriver
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Was this helpful?
Thank you for voting!
Broken cup water fill on ice maker
13 of 15 people
found this instruction helpful.
-
Matthew from Aurora, CO
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.
Thanks,
Matt
Thanks,
Matt
Was this helpful?
Thank you for voting!
replace defrost heater
12 of 15 people
found this instruction helpful.
-
PAUL from BOLINGBROOK, IL
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers
unplug refrigerator. remove contents from freezer. remove shelves, trays, icebucket, light cover & bulb. defrost back panel w/hair dryer. remove screws from: ice dispenser motor housing, back cover. remove back cover. defrost evaporator w/hair dryer. remove heater leads from connector on feedthru. remove heater mounting screws. pull leads
... Read more
down thru evaporator while removing heaters. install new heaters on mounting plates. feed leads up thru evaporator. connect to feedthru. install everything else.
part was exact fit. same resistance as on schematic, leads were long enough. no problems encountered.
part was exact fit. same resistance as on schematic, leads were long enough. no problems encountered.
Read less
Was this helpful?
Thank you for voting!
Refrigerator Ice Maker stopped making ice.
18 of 34 people
found this instruction helpful.
-
Harold from Oakton, VA
- Really Easy
- 15 - 30 mins
-
Nutdriver
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from
... Read more
the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!
Read less
Was this helpful?
Thank you for voting!
the ice/water actuator switch burnt out and was stuck on.
11 of 13 people
found this instruction helpful.
-
Jon from Nampa, ID
- Easy
- 15 - 30 mins
-
Screw drivers
Removed the rubber cover over the actuator switch. Used a screwdriver to remove the switch, disconnected the wires. I then removed the switch from the mounting bracket using a small philips head screw driver. Installed the new switch on the mounting bracket then installed the switch onto the freezer door. The only difficult part was
... Read more
installing the rubber cover. Now I just need to repair the damage to my hardwood floors and carpet from all the water.
Read less
Was this helpful?
Thank you for voting!
Fridge stopped working
10 of 11 people
found this instruction helpful.
-
Dan from Sumner, WA
- Easy
- 15 - 30 mins
-
Nutdriver
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98.
So I used wha ... Read more t he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.
So I used wha ... Read more t he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.
Read less
Was this helpful?
Thank you for voting!
leak in double outlet water valve/solenoid
10 of 12 people
found this instruction helpful.
-
Joel from East Burke, VT
- Easy
- 15 - 30 mins
-
Nutdriver, Wrench set
This was an easy fix. The old one had cracked probably from the frige being left out in cold weather. Just remove the back cover. Unscrew the water line and two plastic lines and unplug the two plugs. Then remove a single screw that holds the valve in place and put on the new one and reattach everything. Good idea to recut the ends o
... Read more
f the tubing to remove old crimp.
Read less
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people
found this instruction helpful.
-
Benjamin from Daytona Beach, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
Read less
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people
found this instruction helpful.
-
Steven from Brigham City, UT
- Really Easy
- 15 - 30 mins
-
Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Read less
Was this helpful?
Thank you for voting!
Leaking water tube connector/union
10 of 12 people
found this instruction helpful.
-
Roderick from NEWTOWN, PA
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
Received the union I ordered, then discovered that the tubes were different sizes, so I had the wrong part. I had read elsewhere that it was necessary to trim the two ends of the tubes with a box cutter to stop the leaks - I did this, and the leaking stopped. I was then able to go to a local hardware store and get a 5/16 to 1/4 union and
... Read more
replace it. The leaking is stopped, and the water supply in the door is now working like new. No problem with partselect, but I did buy a caliper so that I can check tube diameters if I ever have a similar problem! This is a great site to find instructions - well worth the time to search!
Read less
Was this helpful?
Thank you for voting!
Ice bucket auger yoke was stripped out and turned freely
9 of 9 people
found this instruction helpful.
-
James from Pineville, LA
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
Removed the ice bucket from the freezer. Removed the single screw on the left side with a nut driver, then lift and pull the tray toward you...there is a wiring harness in back of the tray that I had to unplug...easy, pinch the sides of the plastic connector and it disconnects..and the tray came out of the refrigerator...and the cussing s
... Read more
tarted. Since the threaded yoke was stripped it could not be unscrewed from the motor shaft...I took my trusty Dremel Tool and cut the shaft off so the yoke could be separated from the motor shaft and the motor could be removed from the plastic housing. From here on it was a piece of cake...install the new motor and screw the new yoke onto the motor shaft... I think it has a left handed thread, like the old propane bottles used to have..slide the tray back in, reconnect the wiring harness (it only plugs in one way), make sure the tray is sitting on the 4 side supports, put the single screw on the left side and you are done....put the ice bucket back in and flip the bail down and you should be back on business....!!
Read less
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people
found this instruction helpful.
-
Lori from Chuluota, FL
- Easy
- Less than 15 mins
-
Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people
found this instruction helpful.
-
JAMES from Middleboro, MA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Read less
Was this helpful?
Thank you for voting!
The freezer section would work OK but the refrigerator stopped cooling
9 of 11 people
found this instruction helpful.
-
Kenneth from Laingsburg, MI
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers
Tips from internet forums helped me figure out the problem: The defroster heaters were not working and the freezer side would frost up and prevent cold air from entering the refrigerator side. I removed the drawers, drawer slides, ice maker, then the back panel to expose the cooling coils. You can check the heaters for continuity before r
... Read more
empving them by disconnecting the two lead wiresonce you have the back panel removed. Not getting any continuity, I removed the old heaters after defrosting the coils. Removing the heaters was the most difficult part as they are a little "long" for where they fit, but with care it can be done, the same applies to installing the new heaters. I had to cut the connecting wire on one of the heaters to remove it, but got the new set installed OK. Works fine now, the bottom heater was defective, and since the are wired in series neither one will work independently. Everything works fine now, problem solved.
Read less
Was this helpful?
Thank you for voting!