EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

5C41B Magic Chef Refrigerator - Instructions

All Instructions for the 5C41B
16 - 30 of 165

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
condenser fan stopped working
10 of 12 people found this instruction helpful.
  • Steven from Brigham City, UT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people found this instruction helpful.
  • Benjamin from Daytona Beach, FL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot al time of ice maker water leak repair and fan replacement about 1 hour.
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people found this instruction helpful.
  • JAMES from Middleboro, MA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people found this instruction helpful.
  • Lori from Chuluota, FL
  • Easy
  • Less than 15 mins
  • Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people found this instruction helpful.
  • George from Glenwood, MN
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Was this helpful?
Thank you for voting!
light not working in fridge
7 of 8 people found this instruction helpful.
  • Michael from East Meadow, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Was this helpful?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
7 of 10 people found this instruction helpful.
  • Antonio from San Antonio, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people found this instruction helpful.
  • David from Choctaw, OK
  • Easy
  • 30 - 60 mins
  • Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people found this instruction helpful.
  • Peter from Herndon, VA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Was this helpful?
Thank you for voting!
light bulb in water ice freezer door went bad
8 of 14 people found this instruction helpful.
  • Carl from RIVERSIDE, CA
  • Very Difficult
  • More than 2 hours
  • Screw drivers
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people found this instruction helpful.
  • Duncan from Metairie, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?
Thank you for voting!
Replace broken ice cube trays
5 of 6 people found this instruction helpful.
  • C MARTIN from TAMPA, FL
  • Really Easy
  • Less than 15 mins
No repair needed. I had only to wash the new ones and use them.
Was this helpful?
Thank you for voting!
refrigerator not cooling properly
6 of 9 people found this instruction helpful.
  • Ernie from Windsor, CA
  • Really Easy
  • 1- 2 hours
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Was this helpful?
Thank you for voting!
Refrigerator light would not stay on
4 of 4 people found this instruction helpful.
  • Dave from Manchester Center, VT
  • Easy
  • 15 - 30 mins
  • Nutdriver, Socket set
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Was this helpful?
Thank you for voting!
Light in my refrigerator didn't work.
5 of 7 people found this instruction helpful.
  • Joseph from Byron Center, MI
  • Really Easy
  • Less than 15 mins
  • Screw drivers
At first I went to a local part supplier and they didn't have it in stock but could order it for me for $55.00 plus $10.00 to ship it. I told them I would have to think about it. I went home and got on the computer and found your web site and was I shocked when I saw the same part listed for $6.98 and $7.00 to ship it. You guys saved m e $50.00. The part arrived in two day and took 5 min. to install. I now have light in my refrigerator. Thank you.
Was this helpful?
Thank you for voting!
All Instructions for the 5C41B
16 - 30 of 165