Leaking Valve on Ice Maker
10 of 12 people found this instruction helpful.
  • Linda from Montgomery, AL
  • A Bit Difficult
  • 15 - 30 mins
  • Pliers, Screw drivers
I ordered the part and it got here very quickly. Being a novice home repair person, it took me awhile to get the courage to start. It was practically uneventful, but it did take some time to figure it out exactly. I did have to bend the piece some, which is always a little nerve wracking. However, the part is working beautifully and I fee l good about myself.
Was this helpful?
Thank you for voting!
Ice maker Stripper lost a tooth
10 of 12 people found this instruction helpful.
  • Ernest W. from Charlotte, NC
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the n ew stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
Was this helpful?
Thank you for voting!
Switchlight was broken on tennant's refridge
10 of 12 people found this instruction helpful.
  • Mark from Somers Point, NJ
  • Easy
  • Less than 15 mins
  • Pliers, Screw drivers
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapp ed the new switch into place.

10 minutes total.
Was this helpful?
Thank you for voting!
Will not make ice
13 of 23 people found this instruction helpful.
  • GEORGE from ELIOT, ME
  • Easy
  • Less than 15 mins
  • Screw drivers
Bing , Bang, Boom.
Was this helpful?
Thank you for voting!
refrigerator did not cool
10 of 14 people found this instruction helpful.
  • Carl from Kent City, MI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
i put a new evaporator motor in and now it works fine
Was this helpful?
Thank you for voting!
Water under refrigerator, leaky ice maker water supply solenoid valve
8 of 8 people found this instruction helpful.
  • Eric from Chicago, IL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
This is a relatively simple repair, but requires a bit of running around your house and sitting in a likely cramped space on the floor behind your refrigerator. These steps assume you have verified the valve is leaking and not the lines. 1. Locate where the water line to the fridge connects to the house plumbing. Close the next valve i n the house plumbing upstream of this connection. Open some fixture (likely the cold on the kitchen sink) to relieve water pressure in this section of plumbing. Water should flow briefly, then dribble and stop on its own. 2. Unplug your fridge. There are moving parts (a fan) close to the valve that may injure you while you are working. 3. Pull your fridge away from the wall enough so you can scoot behind and sit behind. 4. Gather your tools and parts and squeeze behind the fridge. 5. Remove the felt paper dust cover. Carefully collect the screws. 6. Take a picture of the electrical connection to the valve or make a mental note. 7. Carefully unclip lines from the fridge and remove screws holding valve to fridge body. Slicing a line will create a new problem to fix. Carefully collect the screws. 8. Remove electrical connection. Grasp the connector and pull firmly. Do not yank the wires. 9. Over the bucket, disconnect old valve from lines. Some residual water will flow out. If the stream is steady, double check that Step 1 is completed correctly. Set old valve aside. 10. Examine new valve to determine water input and outlet. There may be an arrow indicating flow direction. 11. Seat the input line in the valve input firmly and connect. Mine was a nut I tightened with a small crescent wrench. 12. Seat the outlet line in the valve outlet firmly and connect. Mine was a push in quick connect. 14. Rest the valve over the bucket. Get up and turn the water back on. Verify your connections are not leaking. 15. Review your picture and reconnect the electrical connection. 16. Install the new valve onto the fridge body. Mine was a different geometry that required some gentle bending of the mounting bracket. Reclip lines to fridge. 17. While you're down there, vacuum underneath your fridge. 18. Reinstall felt paper dust cover. 19. Plug fridge back in. Clean up. 20. Monitor your ice maker, verify good operation. When satisfied, push fridge back. Recycle(?) old valve. 21. Success!
Was this helpful?
Thank you for voting!
Freezer not getting cold enough to freeze ice cream
8 of 10 people found this instruction helpful.
  • Gary from ROSETO, PA
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
I took the advice off of your website about the only thing that will fix
the problem is change the run capacitor. I felt assured that I would
have a working refrigerator freezer after making this change. I was
pretty disheartened when it didn`t solve anything. I was not going to
take the new part back out after the sma ll challenge of putting it in.
The next day I found out how to test the old capacitor and it was still
good. I will just have to eat the $49. I did learn not to take advice from
a website even if it seems like a sure thing
Was this helpful?
Thank you for voting!
Noisy freezer evaporator fan, bearings worn out
8 of 10 people found this instruction helpful.
  • Todd from Saint Paul, MN
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
Was this helpful?
Thank you for voting!
Broken gear
8 of 10 people found this instruction helpful.
  • D.H. from Mulberry, AL
  • Easy
  • 15 - 30 mins
  • Screw drivers
Removed old gear and tapped the replacement on.
Was this helpful?
Thank you for voting!
Twice I ordered the oven light bulb & each time the light bulb was defected
17 of 37 people found this instruction helpful.
  • Barbara from BELLEVUE, WA
  • Very Difficult
  • Less than 15 mins
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appl iance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Was this helpful?
Thank you for voting!
no water in ice maker
7 of 8 people found this instruction helpful.
  • O.J. from SUFFOLK, VA
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
Change out water valve.. to find out my temp setting was to high. My kids changed the setting.. so my ice maker didnt work. The water valve will not open until it senses the right temp. Hope this help someone. But my part was here the next day
Was this helpful?
Thank you for voting!
Ice maker would not shut off
8 of 12 people found this instruction helpful.
  • Jack from Bloomington, IL
  • Easy
  • 15 - 30 mins
Removed the ice maker from the freezer. Removed the switch. Tested the switch with a multimeter. Ordered a new switch. Replaced it in the box. Installed the ice maker ( 3screws and electric cord plug. It works. Details available on the internet.
Was this helpful?
Thank you for voting!
stopped making ice
7 of 9 people found this instruction helpful.
  • Timothy from Orange Park, FL
  • Easy
  • 15 - 30 mins
  • Nutdriver
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove fro m hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
Was this helpful?
Thank you for voting!
My ice maker quit making ice.
8 of 12 people found this instruction helpful.
  • Steve from Louisville, KY
  • Easy
  • 15 - 30 mins
  • Screw drivers
I removed the maker from the freezer, three phillps head screws, I pulled off the white plastic cover and found the top (small) gear had poped out, after carefull inspection, I notice two missing teeth. I ordered a new gear from ParstSelect re-installed and with in two days my ice maker was working like new. I estimate I saved myself seve al hundred dollars, my wife wanted to call a service professional or worse buy a new refrigerator freezer. Thanks PartSelect!
Was this helpful?
Thank you for voting!
broken fan blade in the freezer compartment
7 of 9 people found this instruction helpful.
  • John from Cumberland, MD
  • Really Easy
  • Less than 15 mins
  • Pliers
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.